1-1/4 HP R-454A walk-in cooler refrigeration system
Updated
1 1/4 HP is not a standard cooler package size (those run from 1/2 HP on a 6x6 to 1 1/2 HP on a 10x12). We choose it at quote when the heat load calls for about 12,700 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 8 current R-454A condensing units at 1-1/4 HP, rated 12,660 BTU/h at 95°F ambient, with the 16 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 13,200 BTU/h at 90°F ambient and 12,660 BTU/h at 95°F, about 1.1 tons of refrigeration.
- Next sizes. Smaller: 1 HP R-454A walk-in cooler system (9,350 to 10,230 BTU/h). Larger: 1-1/2 HP R-454A walk-in cooler system (13,970 BTU/h).
- Same horsepower in R-448A. 1-1/4 HP R-448A walk-in cooler system, 4 condensing units, 12,140 BTU/h at 95°F ambient.
1-1/4 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON150E4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 13,200 | 12,660 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WBON150E4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 13,200 | 12,660 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WBON150E4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 13,200 | 12,660 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WFON150E4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 13,200 | 12,660 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WFON150E4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 13,200 | 12,660 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WFON150E4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 13,200 | 12,660 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WFON150E4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 13,200 | 12,660 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
| WFON150E4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 13,200 | 12,660 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 205 lb |
Manufacturer ratings at 25°F suction.
Which 1 1/4 HP R-454A model fits your site
1 1/4 HP R-454A is rated up to 12,660 BTU/h at 95°F (about 1.1 tons) at 25°F suction, from 8 Next-Gen Mini-Con models. Compared with the 1 HP below it: 2,430 BTU/h more (24%), a different cabinet, 205 lb against 195 lb. Of its 16 matched unit coolers, 8 also serve the 1 HP. The 1 1/2 HP above it is rated 13,970 BTU/h: the same cabinet, 210 lb against 205 lb here.
- Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 205 lb; 13,200 BTU/h at 90°F and 12,660 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBON150E4ADA on 208-230 V single phase; WBON150E4AEA on 208-230 V three phase; WBON150E4AGA on 460 V three phase.
- Outdoors only. WFON150E4ADA and WFON150E4ADANT on 208-230 V single phase; WFON150E4AEA and WFON150E4AEANT on 208-230 V three phase; WFON150E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 1 1/4 HP in R-448A (4 models, Preassembled Remote) is rated 12,140 BTU/h at 95°F, 4% less at the top of the range than R-454A, and weighs 205 lb. See the 1-1/4 HP R-448A walk-in cooler system.
Evaporators used with this system
A 1-1/4 HP R-454A condensing unit is matched to 16 medium-temperature unit coolers: 8 center mount and 8 low profile, rated 10,300 to 17,300 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6A103ADA 115/1/60 WAE6A103DDA 208-230/1/60 |
10,300 | 1,144 | 2 | 56 × 28-3/8 × 11-1/4″ |
| WAE6A128ADA 115/1/60 WAE6A128DDA 208-230/1/60 |
12,800 | 1,806 | 3 | 76 × 28-3/8 × 11-1/4″ |
| WAE6A157ADA 115/1/60 WAE6A157DDA 208-230/1/60 |
15,700 | 1,716 | 3 | 76 × 28-3/8 × 11-1/4″ |
| WAE6A173ADA 115/1/60 WAE6A173DDA 208-230/1/60 |
17,300 | 2,408 | 4 | 96 × 28-3/8 × 11-1/4″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A113ADA 115/1/60 WAL6A113DDA 208-230/1/60 |
11,300 | 1,570 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A141ADA 115/1/60 WAL6A141DDA 208-230/1/60 |
14,100 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A159ADA 115/1/60 WAL6A159DDA 208-230/1/60 |
15,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A170ADA 115/1/60 WAL6A170DDA 208-230/1/60 |
17,000 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
1-1/4 HP R-454A cooler system questions
How many BTU is a 1 1/4 HP R-454A walk-in cooler system?
The 8 R-454A condensing units in this class are rated 13,200 BTU/h at 90°F ambient and 12,660 BTU/h at 95°F, about 1.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 12,140 BTU/h.
What size walk-in cooler does a 1 1/4 HP system fit?
1 1/4 HP is not a standard cooler package size (those run from 1/2 HP on a 6x6 to 1 1/2 HP on a 10x12). We choose it at quote when the heat load calls for about 12,700 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.
Which 1 1/4 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON150E4ADA on 208-230 V single phase; WBON150E4AEA on 208-230 V three phase; WBON150E4AGA on 460 V three phase. Outdoors only: WFON150E4ADA and WFON150E4ADANT on 208-230 V single phase; WFON150E4AEA and WFON150E4AEANT on 208-230 V three phase; WFON150E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 1 1/4 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON150E4ADA, WFON150E4ADA and WFON150E4ADANT. 208-230 V three phase: WBON150E4AEA, WFON150E4AEA and WFON150E4AEANT. 460 V three phase: WBON150E4AGA and WFON150E4AGA.
How big and heavy is a 1 1/4 HP R-454A condensing unit?
Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 205 lb; 13,200 BTU/h at 90°F and 12,660 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
Is 1 1/4 HP on a standard walk-in cooler package?
No. Our standard coolers use 1 HP on an 8x10 or 10x10 and 1 1/2 HP on a 10x12. The 1 1/4 HP, rated 12,660 BTU/h at 95°F, is picked at quote for a load that falls between them.
How does 1 1/4 HP R-454A compare with R-448A?
It is rated 520 BTU/h higher at 95°F, 12,660 against 12,140, about 4%, in a cabinet of the same size at the same 205 lb. R-454A comes in eight models against four and adds 460 V three phase.
Need a 1 1/4 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 1 1/4 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.