1-1/2 HP R-454A walk-in cooler refrigeration system
Updated
A 1 1/2 HP R-454A system fits our standard 10x12 walk-in cooler package (7′6″ high, held at 35°F). Past 10x12, or with glass doors or an outdoor location, the horsepower is worked out again at quote. This class has 8 current R-454A condensing units at 1-1/2 HP, rated 13,970 BTU/h at 95°F ambient, with the 14 unit coolers matched to that capacity.
- Capacity. 14,660 BTU/h at 90°F ambient and 13,970 BTU/h at 95°F, about 1.2 tons of refrigeration.
- Next sizes. Smaller: 1-1/4 HP R-454A walk-in cooler system (12,660 BTU/h). Larger: 2 HP R-454A walk-in cooler system (16,890 BTU/h).
- Same horsepower in R-448A. 1-1/2 HP R-448A walk-in cooler system, 4 condensing units, 13,690 BTU/h at 95°F ambient.
1-1/2 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON180E4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 14,660 | 13,970 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WBON180E4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 14,660 | 13,970 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WBON180E4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 14,660 | 13,970 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WFON180E4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 14,660 | 13,970 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WFON180E4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 14,660 | 13,970 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WFON180E4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 14,660 | 13,970 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WFON180E4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 14,660 | 13,970 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
| WFON180E4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 14,660 | 13,970 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 18-3/4″ | 210 lb |
Manufacturer ratings at 25°F suction.
Which 1 1/2 HP R-454A model fits your site
1 1/2 HP carries our standard 10x12 walk-in cooler, the largest of the standard cooler packages. In R-454A it is rated 14,660 BTU/h at 90°F and 13,970 at 95°F, 280 above the R-448A version at 95°F, in a cabinet of the same size and the same 210 lb. What this class adds at this size is 460 V three phase service and 14 matched unit coolers against 9.
- Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 210 lb; 14,660 BTU/h at 90°F and 13,970 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBON180E4ADA on 208-230 V single phase; WBON180E4AEA on 208-230 V three phase; WBON180E4AGA on 460 V three phase.
- Outdoors only. WFON180E4ADA and WFON180E4ADANT on 208-230 V single phase; WFON180E4AEA and WFON180E4AEANT on 208-230 V three phase; WFON180E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 1 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 13,690 BTU/h at 95°F, 2% less at the top of the range than R-454A, and weighs 210 lb. See the 1-1/2 HP R-448A walk-in cooler system.
Evaporators used with this system
A 1-1/2 HP R-454A condensing unit is matched to 14 medium-temperature unit coolers: 8 low profile and 6 center mount, rated 11,300 to 17,300 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6A128ADA 115/1/60 WAE6A128DDA 208-230/1/60 |
12,800 | 1,806 | 3 | 76 × 28-3/8 × 11-1/4″ |
| WAE6A157ADA 115/1/60 WAE6A157DDA 208-230/1/60 |
15,700 | 1,716 | 3 | 76 × 28-3/8 × 11-1/4″ |
| WAE6A173ADA 115/1/60 WAE6A173DDA 208-230/1/60 |
17,300 | 2,408 | 4 | 96 × 28-3/8 × 11-1/4″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A113ADA 115/1/60 WAL6A113DDA 208-230/1/60 |
11,300 | 1,570 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A141ADA 115/1/60 WAL6A141DDA 208-230/1/60 |
14,100 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A159ADA 115/1/60 WAL6A159DDA 208-230/1/60 |
15,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A170ADA 115/1/60 WAL6A170DDA 208-230/1/60 |
17,000 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
1-1/2 HP R-454A cooler system questions
How many BTU is a 1 1/2 HP R-454A walk-in cooler system?
The 8 R-454A condensing units in this class are rated 14,660 BTU/h at 90°F ambient and 13,970 BTU/h at 95°F, about 1.2 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 13,690 BTU/h.
What size walk-in cooler does a 1 1/2 HP system fit?
A 1 1/2 HP R-454A system fits our standard 10x12 walk-in cooler package (7′6″ high, held at 35°F). Past 10x12, or with glass doors or an outdoor location, the horsepower is worked out again at quote.
Which 1 1/2 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON180E4ADA on 208-230 V single phase; WBON180E4AEA on 208-230 V three phase; WBON180E4AGA on 460 V three phase. Outdoors only: WFON180E4ADA and WFON180E4ADANT on 208-230 V single phase; WFON180E4AEA and WFON180E4AEANT on 208-230 V three phase; WFON180E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 1 1/2 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON180E4ADA, WFON180E4ADA and WFON180E4ADANT. 208-230 V three phase: WBON180E4AEA, WFON180E4AEA and WFON180E4AEANT. 460 V three phase: WBON180E4AGA and WFON180E4AGA.
How big and heavy is a 1 1/2 HP R-454A condensing unit?
Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 210 lb; 14,660 BTU/h at 90°F and 13,970 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
What separates the 1 1/4 HP and 1 1/2 HP R-454A cooler systems?
About 10% of capacity: 12,660 BTU/h at 95°F for the 1 1/4 HP and 13,970 here, a gap of 1,310. The cabinet is the same size and the weight differs by 5 lb, 205 against 210. All 14 coils on this page also serve the 1 1/4 HP, which adds WAE6A103ADA and WAE6A103DDA.
Which unit coolers drop off when moving up to a 2 HP R-454A system?
WAE6A128 and WAL6A113, each in its 115 V and 208-230 V version. The other ten coils on this page are on the 2 HP list as well.
Which of these unit coolers moves the most air?
The center mount WAE6A173, with 2,408 CFM on four fans at 17,300 BTU/h. The low profile WAL6A170 follows at 2,355 CFM on three fans and 17,000 BTU/h. The smallest coil here is the low profile WAL6A113, 11,300 BTU/h and 1,570 CFM on two fans.
Need a 1 1/2 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 1 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.