2 HP R-454A walk-in cooler refrigeration system
Updated
A 2 HP R-454A system goes on a walk-in cooler that has outgrown the 1 1/2 HP of our standard 10x12 and needs about 16,900 BTU/h at 95°F: a longer or taller custom box, several glass doors or a box outdoors. This class has 8 current R-454A condensing units at 2 HP, rated 16,890 BTU/h at 95°F ambient, with the 25 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 17,670 BTU/h at 90°F ambient and 16,890 BTU/h at 95°F, about 1.4 tons of refrigeration.
- Next sizes. Smaller: 1-1/2 HP R-454A walk-in cooler system (13,970 BTU/h). Larger: 2-1/2 HP R-454A walk-in cooler system (18,490 BTU/h).
- Same horsepower in R-448A. 2 HP R-448A walk-in cooler system, 4 condensing units, 16,840 BTU/h at 95°F ambient.
2 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON200E4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 17,670 | 16,890 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WBON200E4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 17,670 | 16,890 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WBON200E4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 17,670 | 16,890 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WFON200E4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 17,670 | 16,890 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WFON200E4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 17,670 | 16,890 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WFON200E4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 17,670 | 16,890 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WFON200E4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 17,670 | 16,890 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
| WFON200E4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 17,670 | 16,890 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 215 lb |
Manufacturer ratings at 25°F suction.
Which 2 HP R-454A model fits your site
At 2 HP the two refrigerants are rated almost alike: 16,890 BTU/h at 95°F in R-454A and 16,840 in R-448A. Capacity is therefore not the reason to pick one. What R-454A adds here is choice: eight Next-Gen Mini-Con models against four, 460 V three phase service the R-448A class lacks, and 25 matched unit coolers against 10.
- Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 215 lb; 17,670 BTU/h at 90°F and 16,890 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBON200E4ADA on 208-230 V single phase; WBON200E4AEA on 208-230 V three phase; WBON200E4AGA on 460 V three phase.
- Outdoors only. WFON200E4ADA and WFON200E4ADANT on 208-230 V single phase; WFON200E4AEA and WFON200E4AEANT on 208-230 V three phase; WFON200E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 2 HP in R-448A (4 models, Preassembled Remote) is rated 16,840 BTU/h at 95°F, within 1% of R-454A (16,890 BTU/h), and weighs 215 lb. See the 2 HP R-448A walk-in cooler system.
Evaporators used with this system
A 2 HP R-454A condensing unit is matched to 25 medium-temperature unit coolers: 12 low profile, 7 medium profile and 6 center mount, rated 14,100 to 23,400 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6A157ADA 115/1/60 WAE6A157DDA 208-230/1/60 |
15,700 | 1,716 | 3 | 76 × 28-3/8 × 11-1/4″ |
| WAE6A173ADA 115/1/60 WAE6A173DDA 208-230/1/60 |
17,300 | 2,408 | 4 | 96 × 28-3/8 × 11-1/4″ |
| WAE6A207ADA 115/1/60 WAE6A207DDA 208-230/1/60 |
20,700 | 2,288 | 4 | 96 × 28-3/8 × 11-1/4″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A141ADA 115/1/60 WAL6A141DDA 208-230/1/60 |
14,100 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A159ADA 115/1/60 WAL6A159DDA 208-230/1/60 |
15,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A170ADA 115/1/60 WAL6A170DDA 208-230/1/60 |
17,000 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A196ADA 115/1/60 WAL6A196DDA 208-230/1/60 |
19,600 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A220ADA 115/1/60 WAL6A220DDA 208-230/1/60 |
22,000 | 2,325 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A234ADA 115/1/60 WAL6A234DDA 208-230/1/60 |
23,400 | 3,140 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6A219ADA 115/1/60 WAM6A219DDA 208-230/1/60 WAM6A219FDA 460/1/60 |
21,900 | 3,190 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6D218DDA 208-230/1/60 WAM6D218EDA 208-230/3/60 WAM6D218FDA 460/1/60 WAM6D218GDA 460/3/60 |
21,900 | 3,190 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
2 HP R-454A cooler system questions
How many BTU is a 2 HP R-454A walk-in cooler system?
The 8 R-454A condensing units in this class are rated 17,670 BTU/h at 90°F ambient and 16,890 BTU/h at 95°F, about 1.4 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 16,840 BTU/h.
What size walk-in cooler does a 2 HP system fit?
A 2 HP R-454A system goes on a walk-in cooler that has outgrown the 1 1/2 HP of our standard 10x12 and needs about 16,900 BTU/h at 95°F: a longer or taller custom box, several glass doors or a box outdoors.
Which 2 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON200E4ADA on 208-230 V single phase; WBON200E4AEA on 208-230 V three phase; WBON200E4AGA on 460 V three phase. Outdoors only: WFON200E4ADA and WFON200E4ADANT on 208-230 V single phase; WFON200E4AEA and WFON200E4AEANT on 208-230 V three phase; WFON200E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 2 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON200E4ADA, WFON200E4ADA and WFON200E4ADANT. 208-230 V three phase: WBON200E4AEA, WFON200E4AEA and WFON200E4AEANT. 460 V three phase: WBON200E4AGA and WFON200E4AGA.
How big and heavy is a 2 HP R-454A condensing unit?
Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 215 lb; 17,670 BTU/h at 90°F and 16,890 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
What changes between a 1 1/2 HP and a 2 HP R-454A cooler system?
Capacity rises 2,920 BTU/h, about 21%, from 13,970 to 16,890 at 95°F. The footprint stays 28 1/4 × 39 7/8 in.; the cabinet grows 2 1/2 in. taller, to 21 1/4 in., and only 5 lb heavier, 215 lb against 210 lb. The list of matched unit coolers grows from 14 to 25, with 10 in common.
Which 2 HP R-454A unit coolers have electric defrost?
Four medium profile models, all rated 21,900 BTU/h with 3,190 CFM from one fan: WAM6D218DDA on 208-230 V single phase, WAM6D218EDA on 208-230 V three phase, WAM6D218FDA on 460 V single phase and WAM6D218GDA on 460 V three phase. The other 21 coils on this page use air defrost.
Should I choose a 2 HP or a 2 1/2 HP R-454A unit?
Let the heat load decide, because little else separates them. The 2 1/2 HP adds 1,600 BTU/h, about 9%, in the same size cabinet at 15 lb more, and 23 unit coolers serve both. Between these two sizes, WAL6A141 is listed for the 2 HP alone and WAE6A249 for the 2 1/2 HP alone.
What do the ADA and DDA endings mean on these unit coolers?
They mark the same coil at two voltages. ADA is 115 V single phase and DDA is 208-230 V single phase, with the same rating, airflow and fan count: WAL6A170ADA and WAL6A170DDA are both 17,000 BTU/h, 2,355 CFM and three fans. All 18 low profile and center mount coils on this page come in those pairs, so the voltage at the box picks the ending.
What is the range of unit coolers for a 2 HP R-454A system?
From the low profile WAL6A141, 14,100 BTU/h and 1,550 CFM on two fans, up to the low profile WAL6A234, 23,400 BTU/h and 3,140 CFM on four. Center mount coils run from 15,700 to 20,700 BTU/h, and every medium profile coil is rated 21,900.
Need a 2 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.