2-1/2 HP R-454A walk-in cooler refrigeration system
Updated
2 1/2 HP is chosen at quote when the heat load of a walk-in cooler calls for about 18,500 BTU/h at 95°F, more than the 1 1/2 HP of our standard 10x12 delivers: a bigger custom cooler, a glass door box or a cooler outdoors. This class has 8 current R-454A condensing units at 2-1/2 HP, rated 18,490 BTU/h at 95°F ambient, with the 25 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 19,360 BTU/h at 90°F ambient and 18,490 BTU/h at 95°F, about 1.5 tons of refrigeration.
- Next sizes. Smaller: 2 HP R-454A walk-in cooler system (16,890 BTU/h). Larger: 2-3/4 HP R-454A walk-in cooler system (24,880 BTU/h).
- Same horsepower in R-448A. 2-1/2 HP R-448A walk-in cooler system, 4 condensing units, 18,770 BTU/h at 95°F ambient.
2-1/2 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON250E4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 19,360 | 18,490 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WBON250E4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 19,360 | 18,490 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WBON250E4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 19,360 | 18,490 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WFON250E4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 19,360 | 18,490 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WFON250E4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 19,360 | 18,490 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WFON250E4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 19,360 | 18,490 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WFON250E4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 19,360 | 18,490 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
| WFON250E4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 19,360 | 18,490 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 230 lb |
Manufacturer ratings at 25°F suction.
Which 2 1/2 HP R-454A model fits your site
2 1/2 HP R-454A is rated 18,490 BTU/h at 95°F, about 1.5 tons, from eight Next-Gen Mini-Con models at 230 lb. Unlike the 2 1/2 HP R-448A, it includes 460 V three phase models, and it is matched to a wider choice of unit coolers: 25, including 7 medium profile coils.
- Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 230 lb; 19,360 BTU/h at 90°F and 18,490 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBON250E4ADA on 208-230 V single phase; WBON250E4AEA on 208-230 V three phase; WBON250E4AGA on 460 V three phase.
- Outdoors only. WFON250E4ADA and WFON250E4ADANT on 208-230 V single phase; WFON250E4AEA and WFON250E4AEANT on 208-230 V three phase; WFON250E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 2 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 18,770 BTU/h at 95°F, 2% more at the top of the range than R-454A, and weighs 230 lb. See the 2-1/2 HP R-448A walk-in cooler system.
Evaporators used with this system
A 2-1/2 HP R-454A condensing unit is matched to 25 medium-temperature unit coolers: 10 low profile, 8 center mount and 7 medium profile, rated 15,700 to 24,900 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6A157ADA 115/1/60 WAE6A157DDA 208-230/1/60 |
15,700 | 1,716 | 3 | 76 × 28-3/8 × 11-1/4″ |
| WAE6A173ADA 115/1/60 WAE6A173DDA 208-230/1/60 |
17,300 | 2,408 | 4 | 96 × 28-3/8 × 11-1/4″ |
| WAE6A207ADA 115/1/60 WAE6A207DDA 208-230/1/60 |
20,700 | 2,288 | 4 | 96 × 28-3/8 × 11-1/4″ |
| WAE6A249ADA 115/1/60 WAE6A249DDA 208-230/1/60 |
24,900 | 2,860 | 5 | 116 × 28-3/8 × 11-1/4″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A159ADA 115/1/60 WAL6A159DDA 208-230/1/60 |
15,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A170ADA 115/1/60 WAL6A170DDA 208-230/1/60 |
17,000 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A196ADA 115/1/60 WAL6A196DDA 208-230/1/60 |
19,600 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A220ADA 115/1/60 WAL6A220DDA 208-230/1/60 |
22,000 | 2,325 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A234ADA 115/1/60 WAL6A234DDA 208-230/1/60 |
23,400 | 3,140 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6A219ADA 115/1/60 WAM6A219DDA 208-230/1/60 WAM6A219FDA 460/1/60 |
21,900 | 3,190 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6D218DDA 208-230/1/60 WAM6D218EDA 208-230/3/60 WAM6D218FDA 460/1/60 WAM6D218GDA 460/3/60 |
21,900 | 3,190 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
2-1/2 HP R-454A cooler system questions
How many BTU is a 2 1/2 HP R-454A walk-in cooler system?
The 8 R-454A condensing units in this class are rated 19,360 BTU/h at 90°F ambient and 18,490 BTU/h at 95°F, about 1.5 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 18,770 BTU/h.
What size walk-in cooler does a 2 1/2 HP system fit?
2 1/2 HP is chosen at quote when the heat load of a walk-in cooler calls for about 18,500 BTU/h at 95°F, more than the 1 1/2 HP of our standard 10x12 delivers: a bigger custom cooler, a glass door box or a cooler outdoors.
Which 2 1/2 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON250E4ADA on 208-230 V single phase; WBON250E4AEA on 208-230 V three phase; WBON250E4AGA on 460 V three phase. Outdoors only: WFON250E4ADA and WFON250E4ADANT on 208-230 V single phase; WFON250E4AEA and WFON250E4AEANT on 208-230 V three phase; WFON250E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 2 1/2 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON250E4ADA, WFON250E4ADA and WFON250E4ADANT. 208-230 V three phase: WBON250E4AEA, WFON250E4AEA and WFON250E4AEANT. 460 V three phase: WBON250E4AGA and WFON250E4AGA.
How big and heavy is a 2 1/2 HP R-454A condensing unit?
Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 230 lb; 19,360 BTU/h at 90°F and 18,490 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
How big is the jump from 2 1/2 HP to 2 3/4 HP in R-454A?
Large: 18,490 to 24,880 BTU/h at 95°F, a gain of 6,390 or about 35%. The machine grows with it, from 28 1/4 × 39 7/8 × 21 1/4 in. at 230 lb to 33 × 43 7/8 × 35 in. at 305 lb. Of the 25 coils listed here, 15 carry over to the larger size.
What is the largest unit cooler matched to a 2 1/2 HP R-454A system?
By rating, the center mount WAE6A249: 24,900 BTU/h, 2,860 CFM and five fans, as WAE6A249ADA on 115 V or WAE6A249DDA on 208-230 V. The 2 HP class does not list it. Next comes the low profile WAL6A234 at 23,400 BTU/h, which moves more air, 3,140 CFM, with four fans. At the small end, center mount coils start at 15,700 BTU/h and low profile coils at 15,900.
Is the 2 1/2 HP R-454A unit the same size as the R-448A one?
Yes, both measure 28 1/4 × 39 7/8 × 21 1/4 in. and weigh 230 lb. The R-448A is rated 18,770 BTU/h at 95°F, 280 more, or about 1.5%. The refrigerants do not share a unit cooler, so a coil chosen for one does not carry over to the other.
Which 2 1/2 HP R-454A unit coolers run on 460 V?
Only medium profile coils: WAM6A219FDA with air defrost on 460 V single phase, and WAM6D218FDA and WAM6D218GDA with electric defrost on 460 V single and three phase. Every center mount and low profile coil in this class is 115 V or 208-230 V single phase, so a 460 V building that wants one of those needs a lower voltage supply for the coil.
Need a 2 1/2 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 2 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.