FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Medium Temperature (Cooler)

2-3/4 HP R-454A walk-in cooler refrigeration system

Updated

2 3/4 HP is picked at quote when a walk-in cooler needs about 24,900 BTU/h at 95°F, nearly double the horsepower of our standard 10x12 (1 1/2 HP): large custom boxes, glass door walls and coolers outdoors. This class has 8 current R-454A condensing units at 2-3/4 HP, rated 24,880 BTU/h at 95°F ambient, with the 35 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 2-3/4 HP walk-in cooler system
2-3/4
Horsepower
24,880
BTU/h at 95°F ambient
8
Condensing units
35
Matched evaporators
8 models

2-3/4 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

2-3/4 HP R-454A Medium Temperature (Cooler) condensing units, 8 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON280E4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 25,970 24,880 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 305 lb
WBON280E4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 25,970 24,880 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WBON280E4AGA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 25,970 24,880 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WFON280E4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 25,970 24,880 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 305 lb
WFON280E4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 25,970 24,880 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 305 lb
WFON280E4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 25,970 24,880 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WFON280E4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 25,970 24,880 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WFON280E4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 25,970 24,880 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 2 3/4 HP R-454A model fits your site

2 3/4 HP R-454A is a big step up from the 2 1/2 HP: 24,880 BTU/h at 95°F against 18,490, about 35% more, in a larger cabinet (33 × 43 7/8 × 35 in., 305 lb against 230 lb). The 3 HP above it uses that same cabinet and weight for 27,380 BTU/h. No R-454A cooler size is matched to more unit coolers than this one: 35, in low profile, medium profile and center mount types, which gives room to work around a low ceiling or an awkward box.

  • Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 25,970 BTU/h at 90°F and 24,880 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON280E4ADA on 208-230 V single phase; WBON280E4AEA on 208-230 V three phase; WBON280E4AGA on 460 V three phase.
  • Outdoors only. WFON280E4ADA and WFON280E4ADANT on 208-230 V single phase; WFON280E4AEA and WFON280E4AEANT on 208-230 V three phase; WFON280E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
35 unit coolers

Evaporators used with this system

A 2-3/4 HP R-454A condensing unit is matched to 35 medium-temperature unit coolers: 21 medium profile, 8 low profile and 6 center mount, rated 20,700 to 33,600 BTU/h.

Center mount, air defrost: 6 models
Model and voltageBTU/hCFMFansL × W × H
WAE6A207ADA 115/1/60
WAE6A207DDA 208-230/1/60
20,700 2,288 4 96 × 28-3/8 × 11-1/4″
WAE6A249ADA 115/1/60
WAE6A249DDA 208-230/1/60
24,900 2,860 5 116 × 28-3/8 × 11-1/4″
WAE6A316ADA 115/1/60
WAE6A316DDA 208-230/1/60
31,600 3,150 5 116 × 28-3/8 × 13-3/4″
Low profile, air defrost: 8 models
Model and voltageBTU/hCFMFansL × W × H
WAL6A220ADA 115/1/60
WAL6A220DDA 208-230/1/60
22,000 2,325 3 60-1/8 × 15-1/2 × 18-1/8″
WAL6A234ADA 115/1/60
WAL6A234DDA 208-230/1/60
23,400 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A289ADA 115/1/60
WAL6A289DDA 208-230/1/60
28,900 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A316ADA 115/1/60
WAL6A316DDA 208-230/1/60
31,600 3,199 4 76-5/8 × 15-1/2 × 18-1/8″
Medium profile, air defrost: 9 models
Model and voltageBTU/hCFMFansL × W × H
WAM6A219ADA 115/1/60
WAM6A219DDA 208-230/1/60
WAM6A219FDA 460/1/60
21,900 3,190 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6A268ADA 115/1/60
WAM6A268DDA 208-230/1/60
WAM6A268FDA 460/1/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6A336ADA 115/1/60
WAM6A336DDA 208-230/1/60
WAM6A336FDA 460/1/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″
Medium profile, electric defrost: 12 models
Model and voltageBTU/hCFMFansL × W × H
WAM6D218DDA 208-230/1/60
WAM6D218EDA 208-230/3/60
WAM6D218FDA 460/1/60
WAM6D218GDA 460/3/60
21,900 3,190 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6D267DDA 208-230/1/60
WAM6D267EDA 208-230/3/60
WAM6D267FDA 460/1/60
WAM6D267GDA 460/3/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6D335DDA 208-230/1/60
WAM6D335EDA 208-230/3/60
WAM6D335FDA 460/1/60
WAM6D335GDA 460/3/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

2-3/4 HP R-454A cooler system questions

How many BTU is a 2 3/4 HP R-454A walk-in cooler system?

The 8 R-454A condensing units in this class are rated 25,970 BTU/h at 90°F ambient and 24,880 BTU/h at 95°F, about 2.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction).

What size walk-in cooler does a 2 3/4 HP system fit?

2 3/4 HP is picked at quote when a walk-in cooler needs about 24,900 BTU/h at 95°F, nearly double the horsepower of our standard 10x12 (1 1/2 HP): large custom boxes, glass door walls and coolers outdoors.

Which 2 3/4 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON280E4ADA on 208-230 V single phase; WBON280E4AEA on 208-230 V three phase; WBON280E4AGA on 460 V three phase. Outdoors only: WFON280E4ADA and WFON280E4ADANT on 208-230 V single phase; WFON280E4AEA and WFON280E4AEANT on 208-230 V three phase; WFON280E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 2 3/4 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON280E4ADA, WFON280E4ADA and WFON280E4ADANT. 208-230 V three phase: WBON280E4AEA, WFON280E4AEA and WFON280E4AEANT. 460 V three phase: WBON280E4AGA and WFON280E4AGA.

How big and heavy is a 2 3/4 HP R-454A condensing unit?

Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 25,970 BTU/h at 90°F and 24,880 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

How does a 2 3/4 HP R-454A system compare with a 3 HP?

Both are eight Next-Gen Mini-Con models in the same 305 lb cabinet. The 2 3/4 HP is rated 24,880 BTU/h at 95°F and the 3 HP 27,380, which is 2,500 more. The 2 3/4 HP is matched to 35 unit coolers and the 3 HP to 28; 26 of them are common to both.

Need a 2 3/4 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 2 3/4 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 2-1/2 HP R-454A freezer  ·  3 HP R-454A cooler →