2-1/2 HP R-454A walk-in freezer refrigeration system
Updated
Our 8x10 and 10x10 walk-in freezer packages carry 2 1/2 HP, one step up from the 2 HP on an 8x8 freezer; all are specified at -10°F with the insulated floor included. Larger freezers, glass door freezers and freezers outdoors are sized at quote. This class has 8 current R-454A condensing units at 2-1/2 HP, rated 8,450 BTU/h at 95°F ambient, with the 8 unit coolers matched to that capacity.
- Capacity. 8,800 BTU/h at 90°F ambient and 8,450 BTU/h at 95°F, about 0.7 tons of refrigeration.
- Next sizes. Smaller: 2-1/3 HP R-454A walk-in freezer system (6,970 BTU/h). Larger: 3 HP R-454A walk-in freezer system (9,390 BTU/h).
- Same horsepower in R-448A. 2-1/2 HP R-448A walk-in freezer system, 4 condensing units, 7,980 BTU/h at 95°F ambient.
2-1/2 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON250L4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 8,800 | 8,450 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WBON250L4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 8,800 | 8,450 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WBON250L4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 8,800 | 8,450 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WFON250L4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,800 | 8,450 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WFON250L4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,800 | 8,450 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WFON250L4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,800 | 8,450 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WFON250L4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,800 | 8,450 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
| WFON250L4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,800 | 8,450 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 240 lb |
Manufacturer ratings at -20°F suction.
Which 2 1/2 HP R-454A model fits your site
2 1/2 HP is the refrigeration on our standard 8x10 and 10x10 walk-in freezers. In R-454A it comes in eight Next-Gen Mini-Con models at 240 lb, including 460 V three phase models that the R-448A version of this size does not have, and it is rated 8,450 BTU/h at 95°F at -20°F suction, about 6% above the R-448A.
- Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 240 lb; 8,800 BTU/h at 90°F and 8,450 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBON250L4ADA on 208-230 V single phase; WBON250L4AEA on 208-230 V three phase; WBON250L4AGA on 460 V three phase.
- Outdoors only. WFON250L4ADA and WFON250L4ADANT on 208-230 V single phase; WFON250L4AEA and WFON250L4AEANT on 208-230 V three phase; WFON250L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 2 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 7,980 BTU/h at 95°F, 6% less at the top of the range than R-454A, and weighs 240 lb. See the 2-1/2 HP R-448A walk-in freezer system.
Evaporators used with this system
A 2-1/2 HP R-454A condensing unit is matched to 8 low-temperature unit coolers: 6 low profile and 2 center mount, rated 7,600 to 11,400 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6E090DDA | 9,000 | 1,204 | 2 | 56 × 28-3/8 × 11-1/4″ |
| WAE6E107DDA | 10,700 | 1,144 | 2 | 56 × 28-3/8 × 11-1/4″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL4E076DDA | 7,600 | 1,570 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6E079DDA | 7,900 | 1,600 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6E092DDA | 9,200 | 1,570 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL4E099DDA | 9,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL6E110DDA | 11,000 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| WAL4E114DDA | 11,400 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.
2-1/2 HP R-454A freezer system questions
How many BTU is a 2 1/2 HP R-454A walk-in freezer system?
The 8 R-454A condensing units in this class are rated 8,800 BTU/h at 90°F ambient and 8,450 BTU/h at 95°F, about 0.7 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-448A the same horsepower is rated 7,980 BTU/h.
What size walk-in freezer does a 2 1/2 HP system fit?
Our 8x10 and 10x10 walk-in freezer packages carry 2 1/2 HP, one step up from the 2 HP on an 8x8 freezer; all are specified at -10°F with the insulated floor included. Larger freezers, glass door freezers and freezers outdoors are sized at quote.
Which 2 1/2 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON250L4ADA on 208-230 V single phase; WBON250L4AEA on 208-230 V three phase; WBON250L4AGA on 460 V three phase. Outdoors only: WFON250L4ADA and WFON250L4ADANT on 208-230 V single phase; WFON250L4AEA and WFON250L4AEANT on 208-230 V three phase; WFON250L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 2 1/2 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON250L4ADA, WFON250L4ADA and WFON250L4ADANT. 208-230 V three phase: WBON250L4AEA, WFON250L4AEA and WFON250L4AEANT. 460 V three phase: WBON250L4AGA and WFON250L4AGA.
How big and heavy is a 2 1/2 HP R-454A condensing unit?
Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 240 lb; 8,800 BTU/h at 90°F and 8,450 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
Need a 2 1/2 HP R-454A system sized for your walk-in freezer?
Send the inside dimensions and what it will store, tell us where the 2 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.