FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Low Temperature (Freezer)

2-1/2 HP R-454A walk-in freezer refrigeration system

Updated

Our 8x10 and 10x10 walk-in freezer packages carry 2 1/2 HP, one step up from the 2 HP on an 8x8 freezer; all are specified at -10°F with the insulated floor included. Larger freezers, glass door freezers and freezers outdoors are sized at quote. This class has 8 current R-454A condensing units at 2-1/2 HP, rated 8,450 BTU/h at 95°F ambient, with the 8 unit coolers matched to that capacity.

Outdoor remote refrigeration condensing unit of the type supplied with a 2-1/2 HP walk-in freezer system
2-1/2
Horsepower
8,450
BTU/h at 95°F ambient
8
Condensing units
8
Matched evaporators
8 models

2-1/2 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

2-1/2 HP R-454A Low Temperature (Freezer) condensing units, 8 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON250L4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 8,800 8,450 208-230/1/60 · 1-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WBON250L4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 8,800 8,450 208-230/3/60 · 3-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WBON250L4AGA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 8,800 8,450 460/3/60 · 3-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WFON250L4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 8,800 8,450 208-230/1/60 · 1-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WFON250L4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 8,800 8,450 208-230/1/60 · 1-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WFON250L4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 8,800 8,450 208-230/3/60 · 3-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WFON250L4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 8,800 8,450 208-230/3/60 · 3-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb
WFON250L4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 8,800 8,450 460/3/60 · 3-ph 28-1/4 × 39-7/8 × 21-1/4″ 240 lb

Manufacturer ratings at -20°F suction.

Choosing the model

Which 2 1/2 HP R-454A model fits your site

2 1/2 HP is the refrigeration on our standard 8x10 and 10x10 walk-in freezers. In R-454A it comes in eight Next-Gen Mini-Con models at 240 lb, including 460 V three phase models that the R-448A version of this size does not have, and it is rated 8,450 BTU/h at 95°F at -20°F suction, about 6% above the R-448A.

  • Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 240 lb; 8,800 BTU/h at 90°F and 8,450 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON250L4ADA on 208-230 V single phase; WBON250L4AEA on 208-230 V three phase; WBON250L4AGA on 460 V three phase.
  • Outdoors only. WFON250L4ADA and WFON250L4ADANT on 208-230 V single phase; WFON250L4AEA and WFON250L4AEANT on 208-230 V three phase; WFON250L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 2 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 7,980 BTU/h at 95°F, 6% less at the top of the range than R-454A, and weighs 240 lb. See the 2-1/2 HP R-448A walk-in freezer system.
8 unit coolers

Evaporators used with this system

A 2-1/2 HP R-454A condensing unit is matched to 8 low-temperature unit coolers: 6 low profile and 2 center mount, rated 7,600 to 11,400 BTU/h.

Center mount, electric defrost, 208-230/1/60: 2 models
ModelBTU/hCFMFansL × W × H
WAE6E090DDA 9,000 1,204 2 56 × 28-3/8 × 11-1/4″
WAE6E107DDA 10,700 1,144 2 56 × 28-3/8 × 11-1/4″
Low profile, electric defrost, 208-230/1/60: 6 models
ModelBTU/hCFMFansL × W × H
WAL4E076DDA 7,600 1,570 2 43-5/8 × 15-1/2 × 18-1/8″
WAL6E079DDA 7,900 1,600 2 43-5/8 × 15-1/2 × 18-1/8″
WAL6E092DDA 9,200 1,570 2 43-5/8 × 15-1/2 × 18-1/8″
WAL4E099DDA 9,900 1,550 2 43-5/8 × 15-1/2 × 18-1/8″
WAL6E110DDA 11,000 1,550 2 43-5/8 × 15-1/2 × 18-1/8″
WAL4E114DDA 11,400 2,355 3 60-1/8 × 15-1/2 × 18-1/8″

Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.

Straight answers

2-1/2 HP R-454A freezer system questions

How many BTU is a 2 1/2 HP R-454A walk-in freezer system?

The 8 R-454A condensing units in this class are rated 8,800 BTU/h at 90°F ambient and 8,450 BTU/h at 95°F, about 0.7 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-448A the same horsepower is rated 7,980 BTU/h.

What size walk-in freezer does a 2 1/2 HP system fit?

Our 8x10 and 10x10 walk-in freezer packages carry 2 1/2 HP, one step up from the 2 HP on an 8x8 freezer; all are specified at -10°F with the insulated floor included. Larger freezers, glass door freezers and freezers outdoors are sized at quote.

Which 2 1/2 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON250L4ADA on 208-230 V single phase; WBON250L4AEA on 208-230 V three phase; WBON250L4AGA on 460 V three phase. Outdoors only: WFON250L4ADA and WFON250L4ADANT on 208-230 V single phase; WFON250L4AEA and WFON250L4AEANT on 208-230 V three phase; WFON250L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 2 1/2 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON250L4ADA, WFON250L4ADA and WFON250L4ADANT. 208-230 V three phase: WBON250L4AEA, WFON250L4AEA and WFON250L4AEANT. 460 V three phase: WBON250L4AGA and WFON250L4AGA.

How big and heavy is a 2 1/2 HP R-454A condensing unit?

Next-Gen Mini-Con, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 240 lb; 8,800 BTU/h at 90°F and 8,450 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

Need a 2 1/2 HP R-454A system sized for your walk-in freezer?

Send the inside dimensions and what it will store, tell us where the 2 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 2-1/2 HP R-454A cooler  ·  2-3/4 HP R-454A cooler →

Call Now Get a Free Quote