FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Medium Temperature (Cooler)

3 HP R-454A walk-in cooler refrigeration system

Updated

3 HP is double the horsepower on our largest standard cooler (1 1/2 HP on a 10x12), so it goes on large custom coolers, glass door boxes with many doors and coolers taking in a lot of warm product. The heat load calculation sets it before anything is quoted. This class has 8 current R-454A condensing units at 3 HP, rated 27,380 BTU/h at 95°F ambient, with the 28 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 3 HP walk-in cooler system
3
Horsepower
27,380
BTU/h at 95°F ambient
8
Condensing units
28
Matched evaporators
8 models

3 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

3 HP R-454A Medium Temperature (Cooler) condensing units, 8 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON300E4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 28,590 27,380 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 305 lb
WBON300E4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 28,590 27,380 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WBON300E4AGA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 28,590 27,380 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WFON300E4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 28,590 27,380 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 305 lb
WFON300E4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 28,590 27,380 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 305 lb
WFON300E4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 28,590 27,380 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WFON300E4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 28,590 27,380 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb
WFON300E4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 28,590 27,380 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 305 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 3 HP R-454A model fits your site

Every 3 HP R-454A model here is a Next-Gen Mini-Con in the same cabinet, about 2.3 tons of refrigeration at 95°F. It comes on all three services, 208-230 V single phase, 208-230 V three phase and 460 V three phase, so the building’s power rarely rules it out.

  • Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 28,590 BTU/h at 90°F and 27,380 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON300E4ADA on 208-230 V single phase; WBON300E4AEA on 208-230 V three phase; WBON300E4AGA on 460 V three phase.
  • Outdoors only. WFON300E4ADA and WFON300E4ADANT on 208-230 V single phase; WFON300E4AEA and WFON300E4AEANT on 208-230 V three phase; WFON300E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 3 HP in R-448A (4 models, Preassembled Remote) is rated 27,960 BTU/h at 95°F, 2% more at the top of the range than R-454A, and weighs 305 lb. See the 3 HP R-448A walk-in cooler system.
28 unit coolers

Evaporators used with this system

A 3 HP R-454A condensing unit is matched to 28 medium-temperature unit coolers: 14 medium profile, 10 low profile and 4 center mount, rated 22,000 to 37,500 BTU/h.

Center mount, air defrost: 4 models
Model and voltageBTU/hCFMFansL × W × H
WAE6A249ADA 115/1/60
WAE6A249DDA 208-230/1/60
24,900 2,860 5 116 × 28-3/8 × 11-1/4″
WAE6A316ADA 115/1/60
WAE6A316DDA 208-230/1/60
31,600 3,150 5 116 × 28-3/8 × 13-3/4″
Low profile, air defrost: 10 models
Model and voltageBTU/hCFMFansL × W × H
WAL6A220ADA 115/1/60
WAL6A220DDA 208-230/1/60
22,000 2,325 3 60-1/8 × 15-1/2 × 18-1/8″
WAL6A234ADA 115/1/60
WAL6A234DDA 208-230/1/60
23,400 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A289ADA 115/1/60
WAL6A289DDA 208-230/1/60
28,900 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A316ADA 115/1/60
WAL6A316DDA 208-230/1/60
31,600 3,199 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A375ADA 115/1/60
WAL6A375DDA 208-230/1/60
37,500 3,875 5 93-1/8 × 15-1/2 × 18-1/8″
Medium profile, air defrost: 6 models
Model and voltageBTU/hCFMFansL × W × H
WAM6A268ADA 115/1/60
WAM6A268DDA 208-230/1/60
WAM6A268FDA 460/1/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6A336ADA 115/1/60
WAM6A336DDA 208-230/1/60
WAM6A336FDA 460/1/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″
Medium profile, electric defrost: 8 models
Model and voltageBTU/hCFMFansL × W × H
WAM6D267DDA 208-230/1/60
WAM6D267EDA 208-230/3/60
WAM6D267FDA 460/1/60
WAM6D267GDA 460/3/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6D335DDA 208-230/1/60
WAM6D335EDA 208-230/3/60
WAM6D335FDA 460/1/60
WAM6D335GDA 460/3/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

3 HP R-454A cooler system questions

How many BTU is a 3 HP R-454A walk-in cooler system?

The 8 R-454A condensing units in this class are rated 28,590 BTU/h at 90°F ambient and 27,380 BTU/h at 95°F, about 2.3 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 27,960 BTU/h.

What size walk-in cooler does a 3 HP system fit?

3 HP is double the horsepower on our largest standard cooler (1 1/2 HP on a 10x12), so it goes on large custom coolers, glass door boxes with many doors and coolers taking in a lot of warm product. The heat load calculation sets it before anything is quoted.

Which 3 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON300E4ADA on 208-230 V single phase; WBON300E4AEA on 208-230 V three phase; WBON300E4AGA on 460 V three phase. Outdoors only: WFON300E4ADA and WFON300E4ADANT on 208-230 V single phase; WFON300E4AEA and WFON300E4AEANT on 208-230 V three phase; WFON300E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 3 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON300E4ADA, WFON300E4ADA and WFON300E4ADANT. 208-230 V three phase: WBON300E4AEA, WFON300E4AEA and WFON300E4AEANT. 460 V three phase: WBON300E4AGA and WFON300E4AGA.

How big and heavy is a 3 HP R-454A condensing unit?

Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 28,590 BTU/h at 90°F and 27,380 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

Which unit coolers are on the 3 HP list but not the 3 1/2 HP list?

WAL6A220 and WAL6A234, each at 115 V and 208-230 V. The 3 1/2 HP lists the larger WAL6A404 in their place, and the other 24 coils serve both sizes.

What is the largest unit cooler for a 3 HP R-454A system?

The low profile WAL6A375, rated 37,500 BTU/h with 3,875 CFM on five fans. It is also the one coil here that the 2 3/4 HP class does not list.

What medium profile coils can a 3 HP R-454A system use?

Two sizes. One is rated 26,800 BTU/h with 2,950 CFM on one fan (WAM6A268 with air defrost, WAM6D267 with electric defrost). The other is rated 33,600 BTU/h with 6,950 CFM on two fans (WAM6A336 and WAM6D335). The air defrost versions run on 115 V, 208-230 V or 460 V single phase; the electric defrost versions on 208-230 V or 460 V, single or three phase.

Need a 3 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 3 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 2-3/4 HP R-454A cooler  ·  3 HP R-454A freezer →