FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Medium Temperature (Cooler)

3-1/2 HP R-454A walk-in cooler refrigeration system

Updated

We quote 3 1/2 HP when a walk-in cooler needs about 30,000 BTU/h at 95°F, more than double the horsepower of our standard 10x12 (1 1/2 HP): big custom rooms, glass door walls and coolers outdoors. This class has 8 current R-454A condensing units at 3-1/2 HP, rated 30,160 BTU/h at 95°F ambient, with the 26 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 3-1/2 HP walk-in cooler system
3-1/2
Horsepower
30,160
BTU/h at 95°F ambient
8
Condensing units
26
Matched evaporators
8 models

3-1/2 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

3-1/2 HP R-454A Medium Temperature (Cooler) condensing units, 8 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON350E4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 31,500 30,160 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 325 lb
WBON350E4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 31,500 30,160 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 325 lb
WBON350E4AGA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 31,500 30,160 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 325 lb
WFON350E4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 31,500 30,160 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 325 lb
WFON350E4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 31,500 30,160 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 325 lb
WFON350E4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 31,500 30,160 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 325 lb
WFON350E4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 31,500 30,160 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 325 lb
WFON350E4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 31,500 30,160 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 325 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 3 1/2 HP R-454A model fits your site

3 1/2 HP R-454A is rated 31,500 BTU/h at 90°F and 30,160 at 95°F, about 2.5 tons, from eight Next-Gen Mini-Con models at 325 lb. Over the 3 HP it adds 2,780 BTU/h, about 10%, and 20 lb in the same cabinet. The next size up, 4 HP, is where a much heavier Next-Gen II series joins the Mini-Con.

  • Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 325 lb; 31,500 BTU/h at 90°F and 30,160 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON350E4ADA on 208-230 V single phase; WBON350E4AEA on 208-230 V three phase; WBON350E4AGA on 460 V three phase.
  • Outdoors only. WFON350E4ADA and WFON350E4ADANT on 208-230 V single phase; WFON350E4AEA and WFON350E4AEANT on 208-230 V three phase; WFON350E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 3 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 29,760 BTU/h at 95°F, 1% less at the top of the range than R-454A, and weighs 325 lb. See the 3-1/2 HP R-448A walk-in cooler system.
26 unit coolers

Evaporators used with this system

A 3-1/2 HP R-454A condensing unit is matched to 26 medium-temperature unit coolers: 14 medium profile, 8 low profile and 4 center mount, rated 24,900 to 40,400 BTU/h.

Center mount, air defrost: 4 models
Model and voltageBTU/hCFMFansL × W × H
WAE6A249ADA 115/1/60
WAE6A249DDA 208-230/1/60
24,900 2,860 5 116 × 28-3/8 × 11-1/4″
WAE6A316ADA 115/1/60
WAE6A316DDA 208-230/1/60
31,600 3,150 5 116 × 28-3/8 × 13-3/4″
Low profile, air defrost: 8 models
Model and voltageBTU/hCFMFansL × W × H
WAL6A289ADA 115/1/60
WAL6A289DDA 208-230/1/60
28,900 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A316ADA 115/1/60
WAL6A316DDA 208-230/1/60
31,600 3,199 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A375ADA 115/1/60
WAL6A375DDA 208-230/1/60
37,500 3,875 5 93-1/8 × 15-1/2 × 18-1/8″
WAL6A404ADA 115/1/60
WAL6A404DDA 208-230/1/60
40,400 4,650 6 109-5/8 × 15-1/2 × 18-1/8″
Medium profile, air defrost: 6 models
Model and voltageBTU/hCFMFansL × W × H
WAM6A268ADA 115/1/60
WAM6A268DDA 208-230/1/60
WAM6A268FDA 460/1/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6A336ADA 115/1/60
WAM6A336DDA 208-230/1/60
WAM6A336FDA 460/1/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″
Medium profile, electric defrost: 8 models
Model and voltageBTU/hCFMFansL × W × H
WAM6D267DDA 208-230/1/60
WAM6D267EDA 208-230/3/60
WAM6D267FDA 460/1/60
WAM6D267GDA 460/3/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6D335DDA 208-230/1/60
WAM6D335EDA 208-230/3/60
WAM6D335FDA 460/1/60
WAM6D335GDA 460/3/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

3-1/2 HP R-454A cooler system questions

How many BTU is a 3 1/2 HP R-454A walk-in cooler system?

The 8 R-454A condensing units in this class are rated 31,500 BTU/h at 90°F ambient and 30,160 BTU/h at 95°F, about 2.5 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 29,760 BTU/h.

What size walk-in cooler does a 3 1/2 HP system fit?

We quote 3 1/2 HP when a walk-in cooler needs about 30,000 BTU/h at 95°F, more than double the horsepower of our standard 10x12 (1 1/2 HP): big custom rooms, glass door walls and coolers outdoors.

Which 3 1/2 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON350E4ADA on 208-230 V single phase; WBON350E4AEA on 208-230 V three phase; WBON350E4AGA on 460 V three phase. Outdoors only: WFON350E4ADA and WFON350E4ADANT on 208-230 V single phase; WFON350E4AEA and WFON350E4AEANT on 208-230 V three phase; WFON350E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 3 1/2 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON350E4ADA, WFON350E4ADA and WFON350E4ADANT. 208-230 V three phase: WBON350E4AEA, WFON350E4AEA and WFON350E4AEANT. 460 V three phase: WBON350E4AGA and WFON350E4AGA.

How big and heavy is a 3 1/2 HP R-454A condensing unit?

Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 325 lb; 31,500 BTU/h at 90°F and 30,160 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

What is the largest unit cooler matched to a 3 1/2 HP R-454A system?

The low profile WAL6A404: 40,400 BTU/h and 4,650 CFM on six fans, as WAL6A404ADA on 115 V or WAL6A404DDA on 208-230 V. The 3 HP class does not list it.

Which coil on this page moves the most air?

The 33,600 BTU/h medium profile coils, at 6,950 CFM from two fans: WAM6A336 with air defrost and WAM6D335 with electric defrost.

How does 3 1/2 HP compare with 4 HP in R-454A?

The 4 HP Next-Gen Mini-Con keeps this cabinet size, weighs 352 lb against 325 and is rated 33,420 BTU/h at 95°F, 3,260 more or about 11%. The 4 HP also comes as a Next-Gen II at 700 lb, rated 32,590, on three phase only. Of the 26 unit coolers here, 24 serve the 4 HP; WAE6A249 does not.

Need a 3 1/2 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 3 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 3 HP R-454A freezer  ·  3-1/2 HP R-454A freezer →

Call Now Get a Free Quote