FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Medium Temperature (Cooler)

4 HP R-454A walk-in cooler refrigeration system

Updated

4 HP is sized at quote for large walk-in coolers, more than twice the horsepower of our standard 10x12 (1 1/2 HP): big custom boxes, glass door walls, coolers outdoors. The heat load calculation sets it; the power on site and the weight the roof or pad can carry then pick the series. This class has 12 current R-454A condensing units at 4 HP, rated 32,590 to 33,420 BTU/h at 95°F ambient, with the 31 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 4 HP walk-in cooler system
4
Horsepower
33,420
BTU/h at 95°F ambient
12
Condensing units
31
Matched evaporators
12 models

4 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

4 HP R-454A Medium Temperature (Cooler) condensing units, 12 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBOS004E4AEA Next-Gen II Indoor / Outdoor Scroll · Non-Flooded 34,010 32,590 208/230/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 700 lb
WBOS004E4AGA Next-Gen II Indoor / Outdoor Scroll · Non-Flooded 34,010 32,590 460/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 700 lb
WBON400E4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 34,940 33,420 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 352 lb
WBON400E4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 34,940 33,420 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 352 lb
WBON400E4AGA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 34,940 33,420 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 352 lb
WFOS004E4AEA Next-Gen II Outdoor Scroll · Flooded 34,010 32,590 208/230/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 700 lb
WFOS004E4AGA Next-Gen II Outdoor Scroll · Flooded 34,010 32,590 460/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 700 lb
WFON400E4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 34,940 33,420 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 352 lb
WFON400E4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 34,940 33,420 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 352 lb
WFON400E4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 34,940 33,420 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 352 lb
WFON400E4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 34,940 33,420 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 352 lb
WFON400E4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 34,940 33,420 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 352 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 4 HP R-454A model fits your site

4 HP R-454A comes in two series rated almost alike, 32,590 and 33,420 BTU/h at 95°F (about 2.7 to 2.8 tons), but built very differently: the Next-Gen Mini-Con weighs 352 lb and runs on every service, single phase included; the Next-Gen II weighs 700 lb and runs on three phase only. Where single phase is all the building has, the Mini-Con is the one.

  • Next-Gen II, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 700 lb; 34,010 BTU/h at 90°F and 32,590 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
  • Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 352 lb; 34,940 BTU/h at 90°F and 33,420 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON400E4ADA on 208-230 V single phase; WBOS004E4AEA and WBON400E4AEA on 208-230 V three phase; WBOS004E4AGA and WBON400E4AGA on 460 V three phase.
  • Outdoors only. WFON400E4ADA and WFON400E4ADANT on 208-230 V single phase; WFOS004E4AEA, WFON400E4AEA and WFON400E4AEANT on 208-230 V three phase; WFOS004E4AGA and WFON400E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 4 HP in R-448A (8 models, Next-Gen II Scroll and Preassembled Remote) is rated 32,160 to 35,030 BTU/h at 95°F, 5% more at the top of the range than R-454A, and weighs 352 to 700 lb. See the 4 HP R-448A walk-in cooler system.
31 unit coolers

Evaporators used with this system

A 4 HP R-454A condensing unit is matched to 31 medium-temperature unit coolers: 21 medium profile, 8 low profile and 2 center mount, rated 26,800 to 44,800 BTU/h.

Center mount, air defrost: 2 models
Model and voltageBTU/hCFMFansL × W × H
WAE6A316ADA 115/1/60
WAE6A316DDA 208-230/1/60
31,600 3,150 5 116 × 28-3/8 × 13-3/4″
Low profile, air defrost: 8 models
Model and voltageBTU/hCFMFansL × W × H
WAL6A289ADA 115/1/60
WAL6A289DDA 208-230/1/60
28,900 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A316ADA 115/1/60
WAL6A316DDA 208-230/1/60
31,600 3,199 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6A375ADA 115/1/60
WAL6A375DDA 208-230/1/60
37,500 3,875 5 93-1/8 × 15-1/2 × 18-1/8″
WAL6A404ADA 115/1/60
WAL6A404DDA 208-230/1/60
40,400 4,650 6 109-5/8 × 15-1/2 × 18-1/8″
Medium profile, air defrost: 9 models
Model and voltageBTU/hCFMFansL × W × H
WAM6A268ADA 115/1/60
WAM6A268DDA 208-230/1/60
WAM6A268FDA 460/1/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6A336ADA 115/1/60
WAM6A336DDA 208-230/1/60
WAM6A336FDA 460/1/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″
WAM6A448ADA 115/1/60
WAM6A448DDA 208-230/1/60
WAM6A448FDA 460/1/60
44,800 6,380 2 80-1/2 × 21-5/16 × 33-7/8″
Medium profile, electric defrost: 12 models
Model and voltageBTU/hCFMFansL × W × H
WAM6D267DDA 208-230/1/60
WAM6D267EDA 208-230/3/60
WAM6D267FDA 460/1/60
WAM6D267GDA 460/3/60
26,800 2,950 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6D335DDA 208-230/1/60
WAM6D335EDA 208-230/3/60
WAM6D335FDA 460/1/60
WAM6D335GDA 460/3/60
33,600 6,950 2 80-1/2 × 21-5/16 × 33-7/8″
WAM6D447DDA 208-230/1/60
WAM6D447EDA 208-230/3/60
WAM6D447FDA 460/1/60
WAM6D447GDA 460/3/60
44,800 6,380 2 80-1/2 × 21-5/16 × 33-7/8″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

4 HP R-454A cooler system questions

How many BTU is a 4 HP R-454A walk-in cooler system?

The 12 R-454A condensing units in this class are rated 34,010 to 34,940 BTU/h at 90°F ambient and 32,590 to 33,420 BTU/h at 95°F, about 2.7 to 2.8 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 32,160 to 35,030 BTU/h.

What size walk-in cooler does a 4 HP system fit?

4 HP is sized at quote for large walk-in coolers, more than twice the horsepower of our standard 10x12 (1 1/2 HP): big custom boxes, glass door walls, coolers outdoors. The heat load calculation sets it; the power on site and the weight the roof or pad can carry then pick the series.

Which 4 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON400E4ADA on 208-230 V single phase; WBOS004E4AEA and WBON400E4AEA on 208-230 V three phase; WBOS004E4AGA and WBON400E4AGA on 460 V three phase. Outdoors only: WFON400E4ADA and WFON400E4ADANT on 208-230 V single phase; WFOS004E4AEA, WFON400E4AEA and WFON400E4AEANT on 208-230 V three phase; WFOS004E4AGA and WFON400E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 4 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON400E4ADA, WFON400E4ADA and WFON400E4ADANT. 208-230 V three phase: WBOS004E4AEA, WBON400E4AEA, WFOS004E4AEA, WFON400E4AEA and WFON400E4AEANT. 460 V three phase: WBOS004E4AGA, WBON400E4AGA, WFOS004E4AGA and WFON400E4AGA.

How big and heavy is a 4 HP R-454A condensing unit?

Next-Gen II, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 700 lb; 34,010 BTU/h at 90°F and 32,590 BTU/h at 95°F; 208-230 V three phase and 460 V three phase. Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 352 lb; 34,940 BTU/h at 90°F and 33,420 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

Need a 4 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 4 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 3-1/2 HP R-454A freezer  ·  4 HP R-454A freezer →