4-1/2 HP R-454A walk-in cooler refrigeration system
Updated
A walk-in cooler that needs about 37,000 BTU/h at 95°F gets 4 1/2 HP at quote, three times the 1 1/2 HP of our standard 10x12: large custom rooms, long glass door walls and coolers outdoors. This class has 8 current R-454A condensing units at 4-1/2 HP, rated 37,170 BTU/h at 95°F ambient, with the 24 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 38,710 BTU/h at 90°F ambient and 37,170 BTU/h at 95°F, about 3.1 tons of refrigeration.
- Next sizes. Smaller: 4 HP R-454A walk-in cooler system (32,590 to 33,420 BTU/h). Larger: 5 HP R-454A walk-in cooler system (36,490 to 43,410 BTU/h).
- Same horsepower in R-448A. 4-1/2 HP R-448A walk-in cooler system, 4 condensing units, 39,190 BTU/h at 95°F ambient.
4-1/2 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON450E4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 38,710 | 37,170 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WBON450E4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 38,710 | 37,170 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WBON450E4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 38,710 | 37,170 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WFON450E4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WFON450E4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WFON450E4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WFON450E4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| WFON450E4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
Manufacturer ratings at 25°F suction.
Which 4 1/2 HP R-454A model fits your site
4 1/2 HP R-454A comes only as the Next-Gen Mini-Con: eight models at 375 lb in the 33 × 43 7/8 × 35 in. cabinet, rated 37,170 BTU/h at 95°F, about 3.1 tons. The 4 HP and 5 HP on either side also come as a Next-Gen II at 700 lb or more; this size does not, and it still out-rates the 5 HP Next-Gen II (36,490 BTU/h). It covers single phase, three phase and 460 V. The 4 1/2 HP R-448A stops at 208-230 V, though it is rated about 5% higher.
- Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 375 lb; 38,710 BTU/h at 90°F and 37,170 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBON450E4ADA on 208-230 V single phase; WBON450E4AEA on 208-230 V three phase; WBON450E4AGA on 460 V three phase.
- Outdoors only. WFON450E4ADA and WFON450E4ADANT on 208-230 V single phase; WFON450E4AEA and WFON450E4AEANT on 208-230 V three phase; WFON450E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 4 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 39,190 BTU/h at 95°F, 5% more at the top of the range than R-454A, and weighs 375 lb. See the 4-1/2 HP R-448A walk-in cooler system.
Evaporators used with this system
A 4-1/2 HP R-454A condensing unit is matched to 24 medium-temperature unit coolers: 14 medium profile, 8 low profile and 2 center mount, rated 31,600 to 47,700 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6A316ADA 115/1/60 WAE6A316DDA 208-230/1/60 |
31,600 | 3,150 | 5 | 116 × 28-3/8 × 13-3/4″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A316ADA 115/1/60 WAL6A316DDA 208-230/1/60 |
31,600 | 3,199 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A375ADA 115/1/60 WAL6A375DDA 208-230/1/60 |
37,500 | 3,875 | 5 | 93-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A404ADA 115/1/60 WAL6A404DDA 208-230/1/60 |
40,400 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A477ADA 115/1/60 WAL6A477DDA 208-230/1/60 |
47,700 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6A336ADA 115/1/60 WAM6A336DDA 208-230/1/60 WAM6A336FDA 460/1/60 |
33,600 | 6,950 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| WAM6A448ADA 115/1/60 WAM6A448DDA 208-230/1/60 WAM6A448FDA 460/1/60 |
44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6D335DDA 208-230/1/60 WAM6D335EDA 208-230/3/60 WAM6D335FDA 460/1/60 WAM6D335GDA 460/3/60 |
33,600 | 6,950 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| WAM6D447DDA 208-230/1/60 WAM6D447EDA 208-230/3/60 WAM6D447FDA 460/1/60 WAM6D447GDA 460/3/60 |
44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
4-1/2 HP R-454A cooler system questions
How many BTU is a 4 1/2 HP R-454A walk-in cooler system?
The 8 R-454A condensing units in this class are rated 38,710 BTU/h at 90°F ambient and 37,170 BTU/h at 95°F, about 3.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 39,190 BTU/h.
What size walk-in cooler does a 4 1/2 HP system fit?
A walk-in cooler that needs about 37,000 BTU/h at 95°F gets 4 1/2 HP at quote, three times the 1 1/2 HP of our standard 10x12: large custom rooms, long glass door walls and coolers outdoors.
Which 4 1/2 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON450E4ADA on 208-230 V single phase; WBON450E4AEA on 208-230 V three phase; WBON450E4AGA on 460 V three phase. Outdoors only: WFON450E4ADA and WFON450E4ADANT on 208-230 V single phase; WFON450E4AEA and WFON450E4AEANT on 208-230 V three phase; WFON450E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 4 1/2 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON450E4ADA, WFON450E4ADA and WFON450E4ADANT. 208-230 V three phase: WBON450E4AEA, WFON450E4AEA and WFON450E4AEANT. 460 V three phase: WBON450E4AGA and WFON450E4AGA.
How big and heavy is a 4 1/2 HP R-454A condensing unit?
Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 375 lb; 38,710 BTU/h at 90°F and 37,170 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
Is a 4 1/2 HP R-454A unit bigger than a 5 HP Next-Gen II?
By rating, yes: 37,170 BTU/h at 95°F against 36,490 for the 5 HP Next-Gen II, at 375 lb against 710 lb. The 5 HP Next-Gen Mini-Con is the larger one at 43,410 BTU/h and 383 lb. Horsepower is a nominal size, so compare BTU/h.
Need a 4 1/2 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 4 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units