3-1/2 HP R-448A walk-in cooler refrigeration system
Updated
3 1/2 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 29,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 4 current R-448A condensing units at 3-1/2 HP, rated 29,760 BTU/h at 95°F ambient, with the 6 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 30,840 BTU/h at 90°F ambient and 29,760 BTU/h at 95°F, about 2.5 tons of refrigeration.
- Next sizes. Smaller: 3 HP R-448A walk-in cooler system (27,960 BTU/h). Larger: 4 HP R-448A walk-in cooler system (32,160 to 35,030 BTU/h).
- Same horsepower in R-454A. 3-1/2 HP R-454A walk-in cooler system, 8 condensing units, 30,160 BTU/h at 95°F ambient.
3-1/2 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBO350E4SDB | Preassembled Remote | Indoor / Outdoor | Scroll | 30,840 | 29,760 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 325 lb |
| WBO350E4SEB | Preassembled Remote | Indoor / Outdoor | Scroll | 30,840 | 29,760 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 325 lb |
| WFO350E4SDA | Preassembled Remote | Outdoor | Scroll | 30,840 | 29,760 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 325 lb |
| WFO350E4SEA | Preassembled Remote | Outdoor | Scroll | 30,840 | 29,760 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 325 lb |
Manufacturer ratings at 25°F suction.
Which 3 1/2 HP R-448A model fits your site
3 1/2 HP R-448A is rated up to 29,760 BTU/h at 95°F (about 2.5 tons) at 25°F suction, from 4 Preassembled Remote models. Compared with the 3 HP below it: 1,800 BTU/h more (6%), the same cabinet, 325 lb against 305 lb. All 6 of its matched unit coolers also serve the 3 HP. The 4 HP above it is rated 35,030 BTU/h: 352 to 700 lb against 325 lb here.
- Preassembled Remote, 4 models: cabinet 33 × 43 7/8 × 35 in., 325 lb; 30,840 BTU/h at 90°F and 29,760 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBO350E4SDB on 208-230 V single phase; WBO350E4SEB on 208-230 V three phase.
- Outdoors only. WFO350E4SDA on 208-230 V single phase; WFO350E4SEA on 208-230 V three phase.
- Other refrigerant. The same 3 1/2 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 30,160 BTU/h at 95°F, 1% more at the top of the range than R-448A, and weighs 325 lb. See the 3-1/2 HP R-454A walk-in cooler system.
Evaporators used with this system
A 3-1/2 HP R-448A condensing unit is matched to 6 medium-temperature unit coolers: 4 low profile and 2 ultra low profile center mount, rated 23,900 to 38,800 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6A204ADAS | 23,900 | 2,860 | 5 | 112 × 28.375 × 11.25″ |
| WE6A258ADAS | 30,400 | 3,150 | 5 | 112 × 28.375 × 13.75″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6A235ADAS | 27,800 | 3,140 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6A260ADAS | 30,400 | 3,100 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6A295ADAS | 36,100 | 3,875 | 5 | 93.125 × 15.5 × 18.125″ |
| WL6A330ADAS | 38,800 | 4,650 | 6 | 109.625 × 15.5 × 18.125″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
3-1/2 HP R-448A cooler system questions
How many BTU is a 3 1/2 HP R-448A walk-in cooler system?
The 4 R-448A condensing units in this class are rated 30,840 BTU/h at 90°F ambient and 29,760 BTU/h at 95°F, about 2.5 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 30,160 BTU/h.
What size walk-in cooler does a 3 1/2 HP system fit?
3 1/2 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 29,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.
Which 3 1/2 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBO350E4SDB on 208-230 V single phase; WBO350E4SEB on 208-230 V three phase. Outdoors only: WFO350E4SDA on 208-230 V single phase; WFO350E4SEA on 208-230 V three phase.
Is the 3 1/2 HP R-448A unit single phase, three phase or 460 V?
208-230 V single phase: WBO350E4SDB and WFO350E4SDA. 208-230 V three phase: WBO350E4SEB and WFO350E4SEA. No model in this class runs on 460 V.
How big and heavy is a 3 1/2 HP R-448A condensing unit?
Preassembled Remote, 4 models: cabinet 33 × 43 7/8 × 35 in., 325 lb; 30,840 BTU/h at 90°F and 29,760 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Need a 3 1/2 HP R-448A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 3 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.