3 HP R-448A walk-in cooler refrigeration system
Updated
In R-448A, 3 HP sits between 2 3/4 HP and 3 1/2 HP. It is chosen at quote when the calculated heat load of the cooler calls for about 28,000 BTU/h at 95°F: a large custom cooler, a cooler with a glass door wall or a cooler outdoors. This class has 4 current R-448A condensing units at 3 HP, rated 27,960 BTU/h at 95°F ambient, with the 7 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 28,900 BTU/h at 90°F ambient and 27,960 BTU/h at 95°F, about 2.3 tons of refrigeration.
- Next sizes. Smaller: 2-3/4 HP R-448A walk-in cooler system (24,100 BTU/h). Larger: 3-1/2 HP R-448A walk-in cooler system (29,760 BTU/h).
- Same horsepower in R-454A. 3 HP R-454A walk-in cooler system, 8 condensing units, 27,380 BTU/h at 95°F ambient.
3 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBO300E4SDB | Preassembled Remote | Indoor / Outdoor | Scroll | 28,900 | 27,960 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 305 lb |
| WBO300E4SEB | Preassembled Remote | Indoor / Outdoor | Scroll | 28,900 | 27,960 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 305 lb |
| WFO300E4SDA | Preassembled Remote | Outdoor | Scroll | 28,900 | 27,960 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 305 lb |
| WFO300E4SEA | Preassembled Remote | Outdoor | Scroll | 28,900 | 27,960 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 305 lb |
Manufacturer ratings at 25°F suction.
Which 3 HP R-448A model fits your site
3 HP R-448A is rated 27,960 BTU/h at 95°F, about 2.3 tons, a little more than the 27,380 of the 3 HP R-454A. The four R-448A models are Preassembled Remote units at 305 lb and run on 208-230 V single or three phase only; a building on 460 V takes the 3 HP R-454A, which has 460 V models.
- Preassembled Remote, 4 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 28,900 BTU/h at 90°F and 27,960 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBO300E4SDB on 208-230 V single phase; WBO300E4SEB on 208-230 V three phase.
- Outdoors only. WFO300E4SDA on 208-230 V single phase; WFO300E4SEA on 208-230 V three phase.
- Other refrigerant. The same 3 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 27,380 BTU/h at 95°F, 2% less at the top of the range than R-448A, and weighs 305 lb. See the 3 HP R-454A walk-in cooler system.
Evaporators used with this system
A 3 HP R-448A condensing unit is matched to 7 medium-temperature unit coolers: 5 low profile and 2 ultra low profile center mount, rated 22,500 to 38,800 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6A204ADAS | 23,900 | 2,860 | 5 | 112 × 28.375 × 11.25″ |
| WE6A258ADAS | 30,400 | 3,150 | 5 | 112 × 28.375 × 13.75″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6A195ADAS | 22,500 | 3,140 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6A235ADAS | 27,800 | 3,140 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6A260ADAS | 30,400 | 3,100 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6A295ADAS | 36,100 | 3,875 | 5 | 93.125 × 15.5 × 18.125″ |
| WL6A330ADAS | 38,800 | 4,650 | 6 | 109.625 × 15.5 × 18.125″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
3 HP R-448A cooler system questions
How many BTU is a 3 HP R-448A walk-in cooler system?
The 4 R-448A condensing units in this class are rated 28,900 BTU/h at 90°F ambient and 27,960 BTU/h at 95°F, about 2.3 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 27,380 BTU/h.
What size walk-in cooler does a 3 HP system fit?
In R-448A, 3 HP sits between 2 3/4 HP and 3 1/2 HP. It is chosen at quote when the calculated heat load of the cooler calls for about 28,000 BTU/h at 95°F: a large custom cooler, a cooler with a glass door wall or a cooler outdoors.
Which 3 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBO300E4SDB on 208-230 V single phase; WBO300E4SEB on 208-230 V three phase. Outdoors only: WFO300E4SDA on 208-230 V single phase; WFO300E4SEA on 208-230 V three phase.
Is the 3 HP R-448A unit single phase, three phase or 460 V?
208-230 V single phase: WBO300E4SDB and WFO300E4SDA. 208-230 V three phase: WBO300E4SEB and WFO300E4SEA. No model in this class runs on 460 V.
How big and heavy is a 3 HP R-448A condensing unit?
Preassembled Remote, 4 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 28,900 BTU/h at 90°F and 27,960 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Need a 3 HP R-448A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 3 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.