FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Medium Temperature (Cooler)

1 HP R-454A walk-in cooler refrigeration system

Updated

A 1 HP system is the standard refrigeration on our 8x10 and 10x10 walk-in cooler packages (7′6″ high, held at 35°F). This class has 13 current R-454A condensing units at 1 HP, rated 9,350 to 10,230 BTU/h at 95°F ambient, with the 14 unit coolers matched to that capacity.

Outdoor remote refrigeration condensing unit of the type supplied with a 1 HP walk-in cooler system
1
Horsepower
10,230
BTU/h at 95°F ambient
13
Condensing units
14
Matched evaporators
13 models

1 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

1 HP R-454A Medium Temperature (Cooler) condensing units, 13 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON100M4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 9,840 9,350 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WBON100M4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 9,840 9,350 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WBON130E4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 10,730 10,230 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WBON130E4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 10,730 10,230 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100M4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 9,840 9,350 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100M4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 9,840 9,350 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100M4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 9,840 9,350 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100M4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 9,840 9,350 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON130E4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 10,730 10,230 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON130E4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 10,730 10,230 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON130E4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 10,730 10,230 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON130E4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 10,730 10,230 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON130E4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 10,730 10,230 460/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 1 HP R-454A model fits your site

1 HP R-454A is rated up to 10,230 BTU/h at 95°F (about 0.9 tons) at 25°F suction, from 13 Next-Gen Mini-Con models. Compared with the 3/4 HP below it: 1,860 BTU/h more (22%), the same cabinet and weight. It adds 460 V three phase, which the 3/4 HP does not offer. Of its 14 matched unit coolers, 10 also serve the 3/4 HP. The 1 1/4 HP above it is rated 12,660 BTU/h: a different cabinet, 205 lb against 195 lb here.

  • Next-Gen Mini-Con, 13 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 9,840 to 10,730 BTU/h at 90°F and 9,350 to 10,230 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON100M4ADA and WBON130E4ADA on 208-230 V single phase; WBON100M4AEA and WBON130E4AEA on 208-230 V three phase.
  • Outdoors only. WFON100M4ADA, WFON100M4ADANT, WFON130E4ADA and WFON130E4ADANT on 208-230 V single phase; WFON100M4AEA, WFON100M4AEANT, WFON130E4AEA and WFON130E4AEANT on 208-230 V three phase; WFON130E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 1 HP in R-448A (8 models, Preassembled Remote) is rated 9,380 to 9,680 BTU/h at 95°F, 5% less at the top of the range than R-454A, and weighs 195 lb. See the 1 HP R-448A walk-in cooler system.
14 unit coolers

Evaporators used with this system

A 1 HP R-454A condensing unit is matched to 14 medium-temperature unit coolers: 8 low profile and 6 center mount, rated 8,100 to 14,100 BTU/h.

Center mount, air defrost: 6 models
Model and voltageBTU/hCFMFansL × W × H
WAE6A085ADA 115/1/60
WAE6A085DDA 208-230/1/60
8,500 1,204 2 56 × 28-3/8 × 11-1/4″
WAE6A103ADA 115/1/60
WAE6A103DDA 208-230/1/60
10,300 1,144 2 56 × 28-3/8 × 11-1/4″
WAE6A128ADA 115/1/60
WAE6A128DDA 208-230/1/60
12,800 1,806 3 76 × 28-3/8 × 11-1/4″
Low profile, air defrost: 8 models
Model and voltageBTU/hCFMFansL × W × H
WAL6A081ADA 115/1/60
WAL6A081DDA 208-230/1/60
8,100 775 1 27-1/8 × 15-1/2 × 18-1/8″
WAL6A088ADA 115/1/60
WAL6A088DDA 208-230/1/60
8,800 1,600 2 43-5/8 × 15-1/2 × 18-1/8″
WAL6A113ADA 115/1/60
WAL6A113DDA 208-230/1/60
11,300 1,570 2 43-5/8 × 15-1/2 × 18-1/8″
WAL6A141ADA 115/1/60
WAL6A141DDA 208-230/1/60
14,100 1,550 2 43-5/8 × 15-1/2 × 18-1/8″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

1 HP R-454A cooler system questions

How many BTU is a 1 HP R-454A walk-in cooler system?

The 13 R-454A condensing units in this class are rated 9,840 to 10,730 BTU/h at 90°F ambient and 9,350 to 10,230 BTU/h at 95°F, about 0.8 to 0.9 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 9,380 to 9,680 BTU/h.

What size walk-in cooler does a 1 HP system fit?

A 1 HP system is the standard refrigeration on our 8x10 and 10x10 walk-in cooler packages (7′6″ high, held at 35°F). We do the heat load calculation before anything is quoted.

Which 1 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON100M4ADA and WBON130E4ADA on 208-230 V single phase; WBON100M4AEA and WBON130E4AEA on 208-230 V three phase. Outdoors only: WFON100M4ADA, WFON100M4ADANT, WFON130E4ADA and WFON130E4ADANT on 208-230 V single phase; WFON100M4AEA, WFON100M4AEANT, WFON130E4AEA and WFON130E4AEANT on 208-230 V three phase; WFON130E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 1 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON100M4ADA, WBON130E4ADA, WFON100M4ADA, WFON100M4ADANT, WFON130E4ADA and WFON130E4ADANT. 208-230 V three phase: WBON100M4AEA, WBON130E4AEA, WFON100M4AEA, WFON100M4AEANT, WFON130E4AEA and WFON130E4AEANT. 460 V three phase: WFON130E4AGA.

How big and heavy is a 1 HP R-454A condensing unit?

Next-Gen Mini-Con, 13 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 9,840 to 10,730 BTU/h at 90°F and 9,350 to 10,230 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

Need a 1 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 1 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 3/4 HP R-454A cooler  ·  1 HP R-454A freezer →

Call Now Get a Free Quote