FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Medium Temperature (Cooler)

3/4 HP R-454A walk-in cooler refrigeration system

Updated

A 3/4 HP system is the standard refrigeration on our 6x8 and 8x8 walk-in cooler packages (7′6″ high, held at 35°F). This class has 6 current R-454A condensing units at 3/4 HP, rated 8,370 BTU/h at 95°F ambient, with the 10 unit coolers matched to that capacity.

Outdoor remote refrigeration condensing unit of the type supplied with a 3/4 HP walk-in cooler system
3/4
Horsepower
8,370
BTU/h at 95°F ambient
6
Condensing units
10
Matched evaporators
6 models

3/4 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

3/4 HP R-454A Medium Temperature (Cooler) condensing units, 6 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON080M4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 8,740 8,370 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WBON080M4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 8,740 8,370 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON080M4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 8,740 8,370 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON080M4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 8,740 8,370 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON080M4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 8,740 8,370 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON080M4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 8,740 8,370 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 3/4 HP R-454A model fits your site

3/4 HP R-454A is rated up to 8,370 BTU/h at 95°F (about 0.7 tons) at 25°F suction, from 6 Next-Gen Mini-Con models. Compared with the 1/2 HP below it: 1,250 BTU/h more (18%), the same cabinet and weight. Of its 10 matched unit coolers, 6 also serve the 1/2 HP. The 1 HP above it is rated 10,230 BTU/h: the same cabinet and weight.

  • Next-Gen Mini-Con, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 8,740 BTU/h at 90°F and 8,370 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
  • Indoors or outdoors. WBON080M4ADA on 208-230 V single phase; WBON080M4AEA on 208-230 V three phase.
  • Outdoors only. WFON080M4ADA and WFON080M4ADANT on 208-230 V single phase; WFON080M4AEA and WFON080M4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 3/4 HP in R-448A (4 models, Preassembled Remote) is rated 8,020 BTU/h at 95°F, 4% less at the top of the range than R-454A, and weighs 195 lb. See the 3/4 HP R-448A walk-in cooler system.
10 unit coolers

Evaporators used with this system

A 3/4 HP R-454A condensing unit is matched to 10 medium-temperature unit coolers: 6 low profile and 4 center mount, rated 8,100 to 11,300 BTU/h.

Center mount, air defrost: 4 models
Model and voltageBTU/hCFMFansL × W × H
WAE6A085ADA 115/1/60
WAE6A085DDA 208-230/1/60
8,500 1,204 2 56 × 28-3/8 × 11-1/4″
WAE6A103ADA 115/1/60
WAE6A103DDA 208-230/1/60
10,300 1,144 2 56 × 28-3/8 × 11-1/4″
Low profile, air defrost: 6 models
Model and voltageBTU/hCFMFansL × W × H
WAL6A081ADA 115/1/60
WAL6A081DDA 208-230/1/60
8,100 775 1 27-1/8 × 15-1/2 × 18-1/8″
WAL6A088ADA 115/1/60
WAL6A088DDA 208-230/1/60
8,800 1,600 2 43-5/8 × 15-1/2 × 18-1/8″
WAL6A113ADA 115/1/60
WAL6A113DDA 208-230/1/60
11,300 1,570 2 43-5/8 × 15-1/2 × 18-1/8″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

3/4 HP R-454A cooler system questions

How many BTU is a 3/4 HP R-454A walk-in cooler system?

The 6 R-454A condensing units in this class are rated 8,740 BTU/h at 90°F ambient and 8,370 BTU/h at 95°F, about 0.7 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 8,020 BTU/h.

What size walk-in cooler does a 3/4 HP system fit?

A 3/4 HP system is the standard refrigeration on our 6x8 and 8x8 walk-in cooler packages (7′6″ high, held at 35°F). We do the heat load calculation before anything is quoted.

Which 3/4 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON080M4ADA on 208-230 V single phase; WBON080M4AEA on 208-230 V three phase. Outdoors only: WFON080M4ADA and WFON080M4ADANT on 208-230 V single phase; WFON080M4AEA and WFON080M4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 3/4 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON080M4ADA, WFON080M4ADA and WFON080M4ADANT. 208-230 V three phase: WBON080M4AEA, WFON080M4AEA and WFON080M4AEANT. No model in this class runs on 460 V.

How big and heavy is a 3/4 HP R-454A condensing unit?

Next-Gen Mini-Con, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 8,740 BTU/h at 90°F and 8,370 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.

How do the R-454A and R-448A versions of 3/4 HP compare?

R-454A is rated 8,370 BTU/h at 95°F against 8,020, which is 350 more or about 4%, in a cabinet of the same size at the same 195 lb. It comes in six models against four, with 10 matched unit coolers against 8.

Do the 3/4 HP unit coolers also serve the 1 HP R-454A system?

All 10 do. The 1 HP class adds WAE6A128 and WAL6A141, each at 115 V and 208-230 V.

Need a 3/4 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 3/4 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 1/2 HP R-454A cooler  ·  1 HP R-454A cooler →