1/2 HP R-454A walk-in cooler refrigeration system
Updated
A 1/2 HP system is the standard refrigeration on our 6x6 walk-in cooler package (7′6″ high, held at 35°F). This class has 6 current R-454A condensing units at 1/2 HP, rated 7,120 BTU/h at 95°F ambient, with the 8 unit coolers matched to that capacity.
- Capacity. 7,430 BTU/h at 90°F ambient and 7,120 BTU/h at 95°F, about 0.6 tons of refrigeration.
- Next sizes. This is the smallest R-454A cooler class. Larger: 3/4 HP R-454A walk-in cooler system (8,370 BTU/h).
- Same horsepower in R-448A. 1/2 HP R-448A walk-in cooler system, 4 condensing units, 6,580 BTU/h at 95°F ambient.
1/2 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON060M4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 7,430 | 7,120 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WBON060M4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 7,430 | 7,120 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON060M4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 7,430 | 7,120 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON060M4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 7,430 | 7,120 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON060M4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 7,430 | 7,120 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON060M4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 7,430 | 7,120 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
Manufacturer ratings at 25°F suction.
Which 1/2 HP R-454A model fits your site
1/2 HP R-454A is rated up to 7,120 BTU/h at 95°F (about 0.6 tons) at 25°F suction, from 6 Next-Gen Mini-Con models. The 3/4 HP above it is rated 8,370 BTU/h: the same cabinet and weight.
- Next-Gen Mini-Con, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 7,430 BTU/h at 90°F and 7,120 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBON060M4ADA on 208-230 V single phase; WBON060M4AEA on 208-230 V three phase.
- Outdoors only. WFON060M4ADA and WFON060M4ADANT on 208-230 V single phase; WFON060M4AEA and WFON060M4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 6,580 BTU/h at 95°F, 8% less at the top of the range than R-454A, and weighs 195 lb. See the 1/2 HP R-448A walk-in cooler system.
Evaporators used with this system
A 1/2 HP R-454A condensing unit is matched to 8 medium-temperature unit coolers: 6 low profile and 2 center mount, rated 6,200 to 8,800 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6A085ADA 115/1/60 WAE6A085DDA 208-230/1/60 |
8,500 | 1,204 | 2 | 56 × 28-3/8 × 11-1/4″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A062ADA 115/1/60 WAL6A062DDA 208-230/1/60 |
6,200 | 785 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A081ADA 115/1/60 WAL6A081DDA 208-230/1/60 |
8,100 | 775 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A088ADA 115/1/60 WAL6A088DDA 208-230/1/60 |
8,800 | 1,600 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
1/2 HP R-454A cooler system questions
How many BTU is a 1/2 HP R-454A walk-in cooler system?
The 6 R-454A condensing units in this class are rated 7,430 BTU/h at 90°F ambient and 7,120 BTU/h at 95°F, about 0.6 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 6,580 BTU/h.
What size walk-in cooler does a 1/2 HP system fit?
A 1/2 HP system is the standard refrigeration on our 6x6 walk-in cooler package (7′6″ high, held at 35°F). We do the heat load calculation before anything is quoted.
Which 1/2 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON060M4ADA on 208-230 V single phase; WBON060M4AEA on 208-230 V three phase. Outdoors only: WFON060M4ADA and WFON060M4ADANT on 208-230 V single phase; WFON060M4AEA and WFON060M4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 1/2 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON060M4ADA, WFON060M4ADA and WFON060M4ADANT. 208-230 V three phase: WBON060M4AEA, WFON060M4AEA and WFON060M4AEANT. No model in this class runs on 460 V.
How big and heavy is a 1/2 HP R-454A condensing unit?
Next-Gen Mini-Con, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 7,430 BTU/h at 90°F and 7,120 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Is 1/2 HP the smallest R-454A walk-in cooler system?
Yes. It is the smallest R-454A cooler class we list and the size on our standard 6x6 walk-in cooler, rated 7,430 BTU/h at 90°F and 7,120 at 95°F, about 0.6 ton.
What changes going from 1/2 HP to 3/4 HP in R-454A?
Capacity rises 1,250 BTU/h at 95°F, about 18%, to 8,370, while the cabinet size and the 195 lb weight stay put. WAE6A085, WAL6A081 and WAL6A088 serve both sizes. WAL6A062 stops here, and the 3/4 HP adds WAE6A103 and WAL6A113.
Which unit coolers are matched to this size?
Four coils, each offered at 115 V (ending ADA) or 208-230 V (ending DDA). Low profile: WAL6A062 at 6,200 BTU/h and 785 CFM and WAL6A081 at 8,100 and 775, both on one fan, and WAL6A088 at 8,800 and 1,600 on two fans. Center mount: WAE6A085 at 8,500 and 1,204 on two fans.
Need a 1/2 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.