FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-448A · Low Temperature (Freezer)

6 HP R-448A walk-in freezer refrigeration system

Updated

6 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 19,400 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 2 current R-448A condensing units at 6 HP, rated 19,440 BTU/h at 95°F ambient, with the 7 unit coolers matched to that capacity, for a walk-in freezer holding 0°F to -10°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 6 HP walk-in freezer system
6
Horsepower
19,440
BTU/h at 95°F ambient
2
Condensing units
7
Matched evaporators
2 models

6 HP R-448A condensing units

R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.

6 HP R-448A Low Temperature (Freezer) condensing units, 2 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBO600L4SEB Preassembled Remote Indoor / Outdoor Scroll 20,140 19,440 208-230 · 3-ph 33 × 43.875 × 35″ 383 lb
WFO600L4SEB Preassembled Remote Outdoor Scroll 20,140 19,440 208-230 · 3-ph 33 × 43.875 × 35″ 383 lb

Manufacturer ratings at -20°F suction.

Choosing the model

Which 6 HP R-448A model fits your site

6 HP R-448A is rated up to 19,440 BTU/h at 95°F (about 1.6 tons) at -20°F suction, from 2 Preassembled Remote models. Compared with the 5 HP below it: 3,370 BTU/h more (21%), the same cabinet, 383 lb against 367 lb. It has no 208-230 V single phase model, which the 5 HP has. Of its 7 matched unit coolers, 5 also serve the 5 HP.

  • Preassembled Remote, 2 models: cabinet 33 × 43 7/8 × 35 in., 383 lb; 20,140 BTU/h at 90°F and 19,440 BTU/h at 95°F; 208-230 V three phase.
  • Indoors or outdoors. WBO600L4SEB on 208-230 V three phase.
  • Outdoors only. WFO600L4SEB on 208-230 V three phase.
  • Other refrigerant. The same 6 HP in R-454A (5 models, Next-Gen Mini-Con) is rated 20,840 BTU/h at 95°F, 7% more at the top of the range than R-448A, and weighs 383 lb. See the 6 HP R-454A walk-in freezer system.
7 unit coolers

Evaporators used with this system

A 6 HP R-448A condensing unit is matched to 7 low-temperature unit coolers: 4 low profile, 2 ultra low profile center mount and 1 slim display case, rated 16,200 to 25,500 BTU/h.

Ultra low profile center mount, electric defrost, 208-230 V: 2 models
ModelBTU/hCFMFansL × W × H
WE6E182DDS 20,900 2,288 4 92 × 28.375 × 11.25″
WE6E221DDS 25,500 2,860 5 112 × 28.375 × 11.25″
Low profile, electric defrost, 208-230 V: 4 models
ModelBTU/hCFMFansL × W × H
WL6E142DDAS 16,600 2,325 3 60.125 × 15.5 × 18.125″
WL6E162DDAS 18,700 3,140 4 76.625 × 15.5 × 18.125″
WL6E182DDAS 21,000 3,100 4 76.625 × 15.5 × 18.125″
WL6E200DDAS 22,800 3,925 5 93.125 × 15.5 × 18.125″
Slim display case, electric defrost, 208-230 V: 1 model
ModelBTU/hCFMFansL × W × H
ASLE65150DDS 16,200 2,850 6 139 × 19.8125 × 9.1875″

Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.

Straight answers

6 HP R-448A freezer system questions

How many BTU is a 6 HP R-448A walk-in freezer system?

The 2 R-448A condensing units in this class are rated 20,140 BTU/h at 90°F ambient and 19,440 BTU/h at 95°F, about 1.6 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-454A the same horsepower is rated 20,840 BTU/h.

What size walk-in freezer does a 6 HP system fit?

6 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 19,400 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

Which 6 HP R-448A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBO600L4SEB on 208-230 V three phase. Outdoors only: WFO600L4SEB on 208-230 V three phase.

Is the 6 HP R-448A unit single phase, three phase or 460 V?

208-230 V three phase: WBO600L4SEB and WFO600L4SEB. No model in this class runs on 460 V. No model in this class runs on single phase.

How big and heavy is a 6 HP R-448A condensing unit?

Preassembled Remote, 2 models: cabinet 33 × 43 7/8 × 35 in., 383 lb; 20,140 BTU/h at 90°F and 19,440 BTU/h at 95°F; 208-230 V three phase.

Need a 6 HP R-448A system sized for your walk-in freezer?

Send the inside dimensions and what it will store, tell us where the 6 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 6 HP R-448A cooler  ·  1/2 HP R-454A cooler →

Call Now Get a Free Quote