FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-448A · Medium Temperature (Cooler)

6 HP R-448A walk-in cooler refrigeration system

Updated

6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 47,300 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 6 current R-448A condensing units at 6 HP, rated 35,080 to 47,250 BTU/h at 95°F ambient, with the 5 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

  • Capacity. 36,340 to 48,680 BTU/h at 90°F ambient and 35,080 to 47,250 BTU/h at 95°F, about 2.9 to 3.9 tons of refrigeration.
  • Next sizes. Smaller: 5 HP R-448A walk-in cooler system (35,180 to 43,160 BTU/h). This is the largest R-448A cooler class.
  • Same horsepower in R-454A. 6 HP R-454A walk-in cooler system, 9 condensing units, 42,680 to 50,770 BTU/h at 95°F ambient.
Outdoor remote refrigeration condensing unit of the type supplied with a 6 HP walk-in cooler system
6
Horsepower
47,250
BTU/h at 95°F ambient
6
Condensing units
5
Matched evaporators
6 models

6 HP R-448A condensing units

R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.

6 HP R-448A Medium Temperature (Cooler) condensing units, 6 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBOS06E4SEB Next-Gen II Scroll Indoor / Outdoor Scroll · Non-Flooded 36,340 35,080 208/230/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WBOS06E4SGB Next-Gen II Scroll Indoor / Outdoor Scroll · Non-Flooded 36,340 35,080 460/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WBO600E4SEB Preassembled Remote Indoor / Outdoor Scroll 48,680 47,250 208-230 · 3-ph 33 × 43.875 × 35″ 405 lb
WFOS06E4SEA Next-Gen II Scroll Outdoor Scroll · Flooded 36,340 35,080 208/230/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WFOS06E4SGA Next-Gen II Scroll Outdoor Scroll · Flooded 36,340 35,080 460/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WFO600E4SEA Preassembled Remote Outdoor Scroll 48,680 47,250 208-230 · 3-ph 33 × 43.875 × 35″ 405 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 6 HP R-448A model fits your site

6 HP R-448A is rated up to 47,250 BTU/h at 95°F (about 3.9 tons) at 25°F suction, from 6 models in 2 series. Compared with the 5 HP below it: 4,090 BTU/h more (9%), 405 to 710 lb against 383 to 710 lb. It has no 208-230 V single phase model, which the 5 HP has. Both sizes use the same 5 unit coolers.

  • Next-Gen II Scroll, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 36,340 BTU/h at 90°F and 35,080 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
  • Preassembled Remote, 2 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 48,680 BTU/h at 90°F and 47,250 BTU/h at 95°F; 208-230 V three phase.
  • Indoors or outdoors. WBOS06E4SEB and WBO600E4SEB on 208-230 V three phase; WBOS06E4SGB on 460 V three phase.
  • Outdoors only. WFOS06E4SEA and WFO600E4SEA on 208-230 V three phase; WFOS06E4SGA on 460 V three phase.
  • Other refrigerant. The same 6 HP in R-454A (9 models, Next-Gen II and Next-Gen Mini-Con) is rated 42,680 to 50,770 BTU/h at 95°F, 7% more at the top of the range than R-448A, and weighs 405 to 710 lb. See the 6 HP R-454A walk-in cooler system.
5 unit coolers

Evaporators used with this system

A 6 HP R-448A condensing unit is matched to 5 medium-temperature unit coolers: 4 low profile and 1 ultra low profile center mount, rated 30,400 to 45,900 BTU/h.

Ultra low profile center mount, air defrost, 115 V: 1 model
ModelBTU/hCFMFansL × W × H
WE6A258ADAS 30,400 3,150 5 112 × 28.375 × 13.75″
Low profile, air defrost, 115 V: 4 models
ModelBTU/hCFMFansL × W × H
WL6A260ADAS 30,400 3,100 4 76.625 × 15.5 × 18.125″
WL6A295ADAS 36,100 3,875 5 93.125 × 15.5 × 18.125″
WL6A330ADAS 38,800 4,650 6 109.625 × 15.5 × 18.125″
WL6A390ADAS 45,900 4,650 6 109.625 × 15.5 × 18.125″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

6 HP R-448A cooler system questions

How many BTU is a 6 HP R-448A walk-in cooler system?

The 6 R-448A condensing units in this class are rated 36,340 to 48,680 BTU/h at 90°F ambient and 35,080 to 47,250 BTU/h at 95°F, about 2.9 to 3.9 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 42,680 to 50,770 BTU/h.

What size walk-in cooler does a 6 HP system fit?

6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 47,300 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

Which 6 HP R-448A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBOS06E4SEB and WBO600E4SEB on 208-230 V three phase; WBOS06E4SGB on 460 V three phase. Outdoors only: WFOS06E4SEA and WFO600E4SEA on 208-230 V three phase; WFOS06E4SGA on 460 V three phase.

Is the 6 HP R-448A unit single phase, three phase or 460 V?

208-230 V three phase: WBOS06E4SEB, WBO600E4SEB, WFOS06E4SEA and WFO600E4SEA. 460 V three phase: WBOS06E4SGB and WFOS06E4SGA. No model in this class runs on single phase.

How big and heavy is a 6 HP R-448A condensing unit?

Next-Gen II Scroll, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 36,340 BTU/h at 90°F and 35,080 BTU/h at 95°F; 208-230 V three phase and 460 V three phase. Preassembled Remote, 2 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 48,680 BTU/h at 90°F and 47,250 BTU/h at 95°F; 208-230 V three phase.

Why do the two 6 HP R-448A series differ so much?

Horsepower is a nominal size, and these are different machines. The Preassembled Remote is rated 47,250 BTU/h at 95°F and weighs 405 lb; the Next-Gen II Scroll is rated 35,080 BTU/h and weighs 710 lb. Compare BTU/h, then check the power on site, because only the Next-Gen II Scroll has 460 V models.

Are the unit coolers different from the 5 HP R-448A system?

No, both sizes list the same five, all with air defrost on 115 V. The largest is the low profile WL6A390ADAS, at 45,900 BTU/h with 4,650 CFM on six fans.

Need a 6 HP R-448A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 6 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 5 HP R-448A freezer  ·  6 HP R-448A freezer →

Call Now Get a Free Quote