6 HP R-448A walk-in cooler refrigeration system
Updated
6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 47,300 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 6 current R-448A condensing units at 6 HP, rated 35,080 to 47,250 BTU/h at 95°F ambient, with the 5 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 36,340 to 48,680 BTU/h at 90°F ambient and 35,080 to 47,250 BTU/h at 95°F, about 2.9 to 3.9 tons of refrigeration.
- Next sizes. Smaller: 5 HP R-448A walk-in cooler system (35,180 to 43,160 BTU/h). This is the largest R-448A cooler class.
- Same horsepower in R-454A. 6 HP R-454A walk-in cooler system, 9 condensing units, 42,680 to 50,770 BTU/h at 95°F ambient.
6 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBOS06E4SEB | Next-Gen II Scroll | Indoor / Outdoor | Scroll · Non-Flooded | 36,340 | 35,080 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WBOS06E4SGB | Next-Gen II Scroll | Indoor / Outdoor | Scroll · Non-Flooded | 36,340 | 35,080 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WBO600E4SEB | Preassembled Remote | Indoor / Outdoor | Scroll | 48,680 | 47,250 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 405 lb |
| WFOS06E4SEA | Next-Gen II Scroll | Outdoor | Scroll · Flooded | 36,340 | 35,080 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WFOS06E4SGA | Next-Gen II Scroll | Outdoor | Scroll · Flooded | 36,340 | 35,080 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WFO600E4SEA | Preassembled Remote | Outdoor | Scroll | 48,680 | 47,250 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 405 lb |
Manufacturer ratings at 25°F suction.
Which 6 HP R-448A model fits your site
6 HP R-448A is rated up to 47,250 BTU/h at 95°F (about 3.9 tons) at 25°F suction, from 6 models in 2 series. Compared with the 5 HP below it: 4,090 BTU/h more (9%), 405 to 710 lb against 383 to 710 lb. It has no 208-230 V single phase model, which the 5 HP has. Both sizes use the same 5 unit coolers.
- Next-Gen II Scroll, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 36,340 BTU/h at 90°F and 35,080 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
- Preassembled Remote, 2 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 48,680 BTU/h at 90°F and 47,250 BTU/h at 95°F; 208-230 V three phase.
- Indoors or outdoors. WBOS06E4SEB and WBO600E4SEB on 208-230 V three phase; WBOS06E4SGB on 460 V three phase.
- Outdoors only. WFOS06E4SEA and WFO600E4SEA on 208-230 V three phase; WFOS06E4SGA on 460 V three phase.
- Other refrigerant. The same 6 HP in R-454A (9 models, Next-Gen II and Next-Gen Mini-Con) is rated 42,680 to 50,770 BTU/h at 95°F, 7% more at the top of the range than R-448A, and weighs 405 to 710 lb. See the 6 HP R-454A walk-in cooler system.
Evaporators used with this system
A 6 HP R-448A condensing unit is matched to 5 medium-temperature unit coolers: 4 low profile and 1 ultra low profile center mount, rated 30,400 to 45,900 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6A258ADAS | 30,400 | 3,150 | 5 | 112 × 28.375 × 13.75″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6A260ADAS | 30,400 | 3,100 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6A295ADAS | 36,100 | 3,875 | 5 | 93.125 × 15.5 × 18.125″ |
| WL6A330ADAS | 38,800 | 4,650 | 6 | 109.625 × 15.5 × 18.125″ |
| WL6A390ADAS | 45,900 | 4,650 | 6 | 109.625 × 15.5 × 18.125″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
6 HP R-448A cooler system questions
How many BTU is a 6 HP R-448A walk-in cooler system?
The 6 R-448A condensing units in this class are rated 36,340 to 48,680 BTU/h at 90°F ambient and 35,080 to 47,250 BTU/h at 95°F, about 2.9 to 3.9 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 42,680 to 50,770 BTU/h.
What size walk-in cooler does a 6 HP system fit?
6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 47,300 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.
Which 6 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBOS06E4SEB and WBO600E4SEB on 208-230 V three phase; WBOS06E4SGB on 460 V three phase. Outdoors only: WFOS06E4SEA and WFO600E4SEA on 208-230 V three phase; WFOS06E4SGA on 460 V three phase.
Is the 6 HP R-448A unit single phase, three phase or 460 V?
208-230 V three phase: WBOS06E4SEB, WBO600E4SEB, WFOS06E4SEA and WFO600E4SEA. 460 V three phase: WBOS06E4SGB and WFOS06E4SGA. No model in this class runs on single phase.
How big and heavy is a 6 HP R-448A condensing unit?
Next-Gen II Scroll, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 36,340 BTU/h at 90°F and 35,080 BTU/h at 95°F; 208-230 V three phase and 460 V three phase. Preassembled Remote, 2 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 48,680 BTU/h at 90°F and 47,250 BTU/h at 95°F; 208-230 V three phase.
Why do the two 6 HP R-448A series differ so much?
Horsepower is a nominal size, and these are different machines. The Preassembled Remote is rated 47,250 BTU/h at 95°F and weighs 405 lb; the Next-Gen II Scroll is rated 35,080 BTU/h and weighs 710 lb. Compare BTU/h, then check the power on site, because only the Next-Gen II Scroll has 460 V models.
Are the unit coolers different from the 5 HP R-448A system?
No, both sizes list the same five, all with air defrost on 115 V. The largest is the low profile WL6A390ADAS, at 45,900 BTU/h with 4,650 CFM on six fans.
Need a 6 HP R-448A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 6 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.