5 HP R-448A walk-in freezer refrigeration system
Updated
5 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 16,100 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 4 current R-448A condensing units at 5 HP, rated 16,070 BTU/h at 95°F ambient, with the 8 unit coolers matched to that capacity, for a walk-in freezer holding 0°F to -10°F.
- Capacity. 16,700 BTU/h at 90°F ambient and 16,070 BTU/h at 95°F, about 1.3 tons of refrigeration.
- Next sizes. Smaller: 4 HP R-448A walk-in freezer system (12,990 BTU/h). Larger: 6 HP R-448A walk-in freezer system (19,440 BTU/h).
- Same horsepower in R-454A. 5 HP R-454A walk-in freezer system, 8 condensing units, 17,770 BTU/h at 95°F ambient.
5 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBO500L4SDB | Preassembled Remote | Indoor / Outdoor | Scroll | 16,700 | 16,070 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 367 lb |
| WBO500L4SEB | Preassembled Remote | Indoor / Outdoor | Scroll | 16,700 | 16,070 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 367 lb |
| WFO500L4SDB | Preassembled Remote | Outdoor | Scroll | 16,700 | 16,070 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 367 lb |
| WFO500L4SEB | Preassembled Remote | Outdoor | Scroll | 16,700 | 16,070 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 367 lb |
Manufacturer ratings at -20°F suction.
Which 5 HP R-448A model fits your site
5 HP R-448A is rated up to 16,070 BTU/h at 95°F (about 1.3 tons) at -20°F suction, from 4 Preassembled Remote models. Compared with the 4 HP below it: 3,080 BTU/h more (24%), the same cabinet, 367 lb against 352 lb. Of its 8 matched unit coolers, 5 also serve the 4 HP. The 6 HP above it is rated 19,440 BTU/h: the same cabinet, 383 lb against 367 lb here.
- Preassembled Remote, 4 models: cabinet 33 × 43 7/8 × 35 in., 367 lb; 16,700 BTU/h at 90°F and 16,070 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBO500L4SDB on 208-230 V single phase; WBO500L4SEB on 208-230 V three phase.
- Outdoors only. WFO500L4SDB on 208-230 V single phase; WFO500L4SEB on 208-230 V three phase.
- Other refrigerant. The same 5 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 17,770 BTU/h at 95°F, 11% more at the top of the range than R-448A, and weighs 367 lb. See the 5 HP R-454A walk-in freezer system.
Evaporators used with this system
A 5 HP R-448A condensing unit is matched to 8 low-temperature unit coolers: 4 low profile, 3 ultra low profile center mount and 1 slim display case, rated 14,200 to 21,000 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6E125DDS | 14,300 | 1,716 | 3 | 72 × 28.375 × 11.25″ |
| WE6E137DDS | 15,400 | 2,408 | 4 | 92 × 28.375 × 11.25″ |
| WE6E182DDS | 20,900 | 2,288 | 4 | 92 × 28.375 × 11.25″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6E121DDAS | 14,200 | 2,355 | 3 | 60.125 × 15.5 × 18.125″ |
| WL6E142DDAS | 16,600 | 2,325 | 3 | 60.125 × 15.5 × 18.125″ |
| WL6E162DDAS | 18,700 | 3,140 | 4 | 76.625 × 15.5 × 18.125″ |
| WL6E182DDAS | 21,000 | 3,100 | 4 | 76.625 × 15.5 × 18.125″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| ASLE65150DDS | 16,200 | 2,850 | 6 | 139 × 19.8125 × 9.1875″ |
Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.
5 HP R-448A freezer system questions
How many BTU is a 5 HP R-448A walk-in freezer system?
The 4 R-448A condensing units in this class are rated 16,700 BTU/h at 90°F ambient and 16,070 BTU/h at 95°F, about 1.3 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-454A the same horsepower is rated 17,770 BTU/h.
What size walk-in freezer does a 5 HP system fit?
5 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 16,100 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.
Which 5 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBO500L4SDB on 208-230 V single phase; WBO500L4SEB on 208-230 V three phase. Outdoors only: WFO500L4SDB on 208-230 V single phase; WFO500L4SEB on 208-230 V three phase.
Is the 5 HP R-448A unit single phase, three phase or 460 V?
208-230 V single phase: WBO500L4SDB and WFO500L4SDB. 208-230 V three phase: WBO500L4SEB and WFO500L4SEB. No model in this class runs on 460 V.
How big and heavy is a 5 HP R-448A condensing unit?
Preassembled Remote, 4 models: cabinet 33 × 43 7/8 × 35 in., 367 lb; 16,700 BTU/h at 90°F and 16,070 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Need a 5 HP R-448A system sized for your walk-in freezer?
Send the inside dimensions and what it will store, tell us where the 5 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.