FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-454A · Low Temperature (Freezer)

5 HP R-454A walk-in freezer refrigeration system

Updated

5 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 17,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 8 current R-454A condensing units at 5 HP, rated 17,770 BTU/h at 95°F ambient, with the 24 unit coolers matched to that capacity, for a walk-in freezer holding 0°F to -10°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 5 HP walk-in freezer system
5
Horsepower
17,770
BTU/h at 95°F ambient
8
Condensing units
24
Matched evaporators
8 models

5 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.

5 HP R-454A Low Temperature (Freezer) condensing units, 8 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON500L4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 18,460 17,770 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 367 lb
WBON500L4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 18,460 17,770 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 367 lb
WBON500L4AGA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 18,460 17,770 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 367 lb
WFON500L4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 18,460 17,770 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 367 lb
WFON500L4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 18,460 17,770 208-230/1/60 · 1-ph 33 × 43-7/8 × 35″ 367 lb
WFON500L4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 18,460 17,770 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 367 lb
WFON500L4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 18,460 17,770 208-230/3/60 · 3-ph 33 × 43-7/8 × 35″ 367 lb
WFON500L4AGA Next-Gen Mini-Con Outdoor Scroll · Flooded 18,460 17,770 460/3/60 · 3-ph 33 × 43-7/8 × 35″ 367 lb

Manufacturer ratings at -20°F suction.

Choosing the model

Which 5 HP R-454A model fits your site

5 HP R-454A is rated up to 17,770 BTU/h at 95°F (about 1.5 tons) at -20°F suction, from 8 Next-Gen Mini-Con models. Compared with the 4 HP below it: 3,270 BTU/h more (23%), the same cabinet, 367 lb against 352 lb. Of its 24 matched unit coolers, 16 also serve the 4 HP. The 6 HP above it is rated 20,840 BTU/h: the same cabinet, 383 lb against 367 lb here.

  • Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 367 lb; 18,460 BTU/h at 90°F and 17,770 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
  • Indoors or outdoors. WBON500L4ADA on 208-230 V single phase; WBON500L4AEA on 208-230 V three phase; WBON500L4AGA on 460 V three phase.
  • Outdoors only. WFON500L4ADA and WFON500L4ADANT on 208-230 V single phase; WFON500L4AEA and WFON500L4AEANT on 208-230 V three phase; WFON500L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
  • Other refrigerant. The same 5 HP in R-448A (4 models, Preassembled Remote) is rated 16,070 BTU/h at 95°F, 10% less at the top of the range than R-454A, and weighs 367 lb. See the 5 HP R-448A walk-in freezer system.
24 unit coolers

Evaporators used with this system

A 5 HP R-454A condensing unit is matched to 24 low-temperature unit coolers: 12 medium profile, 9 low profile and 3 center mount, rated 14,800 to 23,700 BTU/h.

Center mount, electric defrost, 208-230/1/60: 3 models
ModelBTU/hCFMFansL × W × H
WAE6E149DDA 14,900 1,716 3 76 × 28-3/8 × 11-1/4″
WAE6E160DDA 16,000 2,408 4 96 × 28-3/8 × 11-1/4″
WAE6E217DDA 21,700 2,288 4 96 × 28-3/8 × 11-1/4″
Low profile, electric defrost, 208-230/1/60: 9 models
ModelBTU/hCFMFansL × W × H
WAL6E148DDA 14,800 2,355 3 60-1/8 × 15-1/2 × 18-1/8″
WAL4E150DDA 15,000 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL4E170DDA 17,000 3,100 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6E173DDA 17,300 2,325 3 60-1/8 × 15-1/2 × 18-1/8″
WAL4E184DDA 18,400 3,925 5 93-1/8 × 15-1/2 × 18-1/8″
WAL6E194DDA 19,400 3,140 4 76-5/8 × 15-1/2 × 18-1/8″
WAL6E218DDA 21,800 3,100 4 76-5/8 × 15-1/2 × 18-1/8″
WAL4E232DDA 23,200 4,710 6 109-5/8 × 15-1/2 × 18-1/8″
WAL6E237DDA 23,700 3,925 5 93-1/8 × 15-1/2 × 18-1/8″
Medium profile, electric defrost: 12 models
Model and voltageBTU/hCFMFansL × W × H
WAM4E168DDA 208-230/1/60
WAM4E168EDA 208-230/3/60
WAM4E168FDA 460/1/60
WAM4E168GDA 460/3/60
16,800 3,360 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6E181DDA 208-230/1/60
WAM6E181EDA 208-230/3/60
WAM6E181FDA 460/1/60
WAM6E181GDA 460/3/60
18,100 3,190 1 47-1/2 × 21-5/16 × 33-7/8″
WAM6E217DDA 208-230/1/60
WAM6E217EDA 208-230/3/60
WAM6E217FDA 460/1/60
WAM6E217GDA 460/3/60
21,900 2,950 1 47-1/2 × 21-5/16 × 33-7/8″

Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.

Straight answers

5 HP R-454A freezer system questions

How many BTU is a 5 HP R-454A walk-in freezer system?

The 8 R-454A condensing units in this class are rated 18,460 BTU/h at 90°F ambient and 17,770 BTU/h at 95°F, about 1.5 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-448A the same horsepower is rated 16,070 BTU/h.

What size walk-in freezer does a 5 HP system fit?

5 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 17,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

Which 5 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON500L4ADA on 208-230 V single phase; WBON500L4AEA on 208-230 V three phase; WBON500L4AGA on 460 V three phase. Outdoors only: WFON500L4ADA and WFON500L4ADANT on 208-230 V single phase; WFON500L4AEA and WFON500L4AEANT on 208-230 V three phase; WFON500L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

Is the 5 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON500L4ADA, WFON500L4ADA and WFON500L4ADANT. 208-230 V three phase: WBON500L4AEA, WFON500L4AEA and WFON500L4AEANT. 460 V three phase: WBON500L4AGA and WFON500L4AGA.

How big and heavy is a 5 HP R-454A condensing unit?

Next-Gen Mini-Con, 8 models: cabinet 33 × 43 7/8 × 35 in., 367 lb; 18,460 BTU/h at 90°F and 17,770 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

Is 5 HP the largest R-454A freezer system on single phase?

Yes. WBON500L4ADA, for indoors or outdoors, and the outdoor WFON500L4ADA and WFON500L4ADANT run on 208-230 V single phase. Every 6 HP R-454A freezer model is three phase.

Which unit cooler moves the most air at 5 HP?

The low profile WAL4E232DDA, with 4,710 CFM on six fans at 23,200 BTU/h. The highest rating goes to another low profile coil, WAL6E237DDA: 23,700 BTU/h with 3,925 CFM on five fans.

Need a 5 HP R-454A system sized for your walk-in freezer?

Send the inside dimensions and what it will store, tell us where the 5 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 5 HP R-454A cooler  ·  6 HP R-454A cooler →