6 HP R-454A walk-in cooler refrigeration system
Updated
6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 50,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 9 current R-454A condensing units at 6 HP, rated 42,680 to 50,770 BTU/h at 95°F ambient, with the 26 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 44,200 to 52,580 BTU/h at 90°F ambient and 42,680 to 50,770 BTU/h at 95°F, about 3.6 to 4.2 tons of refrigeration.
- Next sizes. Smaller: 5 HP R-454A walk-in cooler system (36,490 to 43,410 BTU/h). This is the largest R-454A cooler class.
- Same horsepower in R-448A. 6 HP R-448A walk-in cooler system, 6 condensing units, 35,080 to 47,250 BTU/h at 95°F ambient.
6 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBOS006E4AEA | Next-Gen II | Indoor / Outdoor | Scroll · Non-Flooded | 44,200 | 42,680 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WBOS006E4AGA | Next-Gen II | Indoor / Outdoor | Scroll · Non-Flooded | 44,200 | 42,680 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WBON600E4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 52,580 | 50,770 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| WBON600E4AGA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 52,580 | 50,770 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| WFOS006E4AEA | Next-Gen II | Outdoor | Scroll · Flooded | 44,200 | 42,680 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WFOS006E4AGA | Next-Gen II | Outdoor | Scroll · Flooded | 44,200 | 42,680 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| WFON600E4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 52,580 | 50,770 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| WFON600E4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 52,580 | 50,770 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| WFON600E4AGA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 52,580 | 50,770 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
Manufacturer ratings at 25°F suction.
Which 6 HP R-454A model fits your site
6 HP R-454A is rated up to 50,770 BTU/h at 95°F (about 4.2 tons) at 25°F suction, from 9 models in 2 series. Compared with the 5 HP below it: 7,360 BTU/h more (17%), 405 to 710 lb against 383 to 710 lb. It has no 208-230 V single phase model, which the 5 HP has. Of its 26 matched unit coolers, 20 also serve the 5 HP.
- Next-Gen II, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 44,200 BTU/h at 90°F and 42,680 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
- Next-Gen Mini-Con, 5 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 52,580 BTU/h at 90°F and 50,770 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
- Indoors or outdoors. WBOS006E4AEA and WBON600E4AEA on 208-230 V three phase; WBOS006E4AGA and WBON600E4AGA on 460 V three phase.
- Outdoors only. WFOS006E4AEA, WFON600E4AEA and WFON600E4AEANT on 208-230 V three phase; WFOS006E4AGA and WFON600E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 6 HP in R-448A (6 models, Next-Gen II Scroll and Preassembled Remote) is rated 35,080 to 47,250 BTU/h at 95°F, 7% less at the top of the range than R-454A, and weighs 405 to 710 lb. See the 6 HP R-448A walk-in cooler system.
Evaporators used with this system
A 6 HP R-454A condensing unit is matched to 26 medium-temperature unit coolers: 20 medium profile and 6 low profile, rated 37,500 to 66,800 BTU/h.
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL6A375ADA 115/1/60 WAL6A375DDA 208-230/1/60 |
37,500 | 3,875 | 5 | 93-1/8 × 15-1/2 × 18-1/8″ |
| WAL6A404ADA 115/1/60 WAL6A404DDA 208-230/1/60 |
40,400 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |
| WAL6A477ADA 115/1/60 WAL6A477DDA 208-230/1/60 |
47,700 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6A448ADA 115/1/60 WAM6A448DDA 208-230/1/60 WAM6A448FDA 460/1/60 |
44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| WAM6A540ADA 115/1/60 WAM6A540DDA 208-230/1/60 WAM6A540FDA 460/1/60 |
54,000 | 5,900 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| WAM6A668ADA 115/1/60 WAM6A668DDA 208-230/1/60 WAM6A668FDA 460/1/60 |
66,800 | 9,580 | 3 | 113-9/16 × 21-5/16 × 33-7/8″ |
| Model and voltage | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAM6D447DDA 208-230/1/60 WAM6D447EDA 208-230/3/60 WAM6D447FDA 460/1/60 WAM6D447GDA 460/3/60 |
44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| WAM6D539DDA 208-230/1/60 WAM6D539EDA 208-230/3/60 WAM6D539FDA 460/1/60 WAM6D539GDA 460/3/60 |
54,000 | 5,900 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| WAM6D667EDA 208-230/3/60 WAM6D667FDA 460/1/60 WAM6D667GDA 460/3/60 |
66,800 | 9,580 | 3 | 113-9/16 × 21-5/16 × 33-7/8″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
6 HP R-454A cooler system questions
How many BTU is a 6 HP R-454A walk-in cooler system?
The 9 R-454A condensing units in this class are rated 44,200 to 52,580 BTU/h at 90°F ambient and 42,680 to 50,770 BTU/h at 95°F, about 3.6 to 4.2 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 35,080 to 47,250 BTU/h.
What size walk-in cooler does a 6 HP system fit?
6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 50,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.
Which 6 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBOS006E4AEA and WBON600E4AEA on 208-230 V three phase; WBOS006E4AGA and WBON600E4AGA on 460 V three phase. Outdoors only: WFOS006E4AEA, WFON600E4AEA and WFON600E4AEANT on 208-230 V three phase; WFOS006E4AGA and WFON600E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 6 HP R-454A unit single phase, three phase or 460 V?
208-230 V three phase: WBOS006E4AEA, WBON600E4AEA, WFOS006E4AEA, WFON600E4AEA and WFON600E4AEANT. 460 V three phase: WBOS006E4AGA, WBON600E4AGA, WFOS006E4AGA and WFON600E4AGA. No model in this class runs on single phase.
How big and heavy is a 6 HP R-454A condensing unit?
Next-Gen II, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 44,200 BTU/h at 90°F and 42,680 BTU/h at 95°F; 208-230 V three phase and 460 V three phase. Next-Gen Mini-Con, 5 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 52,580 BTU/h at 90°F and 50,770 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
Need a 6 HP R-454A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 6 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.