3/4 HP R-448A walk-in cooler refrigeration system
Updated
A 3/4 HP system is the standard refrigeration on our 6x8 and 8x8 walk-in cooler packages (7′6″ high, held at 35°F). This class has 4 current R-448A condensing units at 3/4 HP, rated 8,020 BTU/h at 95°F ambient, with the 8 unit coolers matched to that capacity.
- Capacity. 8,330 BTU/h at 90°F ambient and 8,020 BTU/h at 95°F, about 0.7 tons of refrigeration.
- Next sizes. Smaller: 1/2 HP R-448A walk-in cooler system (6,580 BTU/h). Larger: 1 HP R-448A walk-in cooler system (9,380 to 9,680 BTU/h).
- Same horsepower in R-454A. 3/4 HP R-454A walk-in cooler system, 6 condensing units, 8,370 BTU/h at 95°F ambient.
3/4 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBO080M4SDB | Preassembled Remote | Indoor / Outdoor | Scroll | 8,330 | 8,020 | 208-230 · 1-ph | 28.25 × 27.875 × 18.75″ | 195 lb |
| WBO080M4SEB | Preassembled Remote | Indoor / Outdoor | Scroll | 8,330 | 8,020 | 208-230 · 3-ph | 28.25 × 27.875 × 18.75″ | 195 lb |
| WFO080M4SDA | Preassembled Remote | Outdoor | Scroll | 8,330 | 8,020 | 208-230 · 1-ph | 28.25 × 27.875 × 18.75″ | 195 lb |
| WFO080M4SEA | Preassembled Remote | Outdoor | Scroll | 8,330 | 8,020 | 208-230 · 3-ph | 28.25 × 27.875 × 18.75″ | 195 lb |
Manufacturer ratings at 25°F suction.
Which 3/4 HP R-448A model fits your site
3/4 HP R-448A is rated up to 8,020 BTU/h at 95°F (about 0.7 tons) at 25°F suction, from 4 Preassembled Remote models. Compared with the 1/2 HP below it: 1,440 BTU/h more (22%), the same cabinet and weight. Of its 8 matched unit coolers, 5 also serve the 1/2 HP. The 1 HP above it is rated 9,680 BTU/h: the same cabinet and weight.
- Preassembled Remote, 4 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 8,330 BTU/h at 90°F and 8,020 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBO080M4SDB on 208-230 V single phase; WBO080M4SEB on 208-230 V three phase.
- Outdoors only. WFO080M4SDA on 208-230 V single phase; WFO080M4SEA on 208-230 V three phase.
- Other refrigerant. The same 3/4 HP in R-454A (6 models, Next-Gen Mini-Con) is rated 8,370 BTU/h at 95°F, 4% more at the top of the range than R-448A, and weighs 195 lb. See the 3/4 HP R-454A walk-in cooler system.
Evaporators used with this system
A 3/4 HP R-448A condensing unit is matched to 8 medium-temperature unit coolers: 3 low profile, 3 slim display case and 2 ultra low profile center mount, rated 6,500 to 10,900 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6A070ADAS | 8,200 | 1,204 | 2 | 52 × 28.375 × 11.25″ |
| WE6A084ADAS | 9,900 | 1,144 | 2 | 52 × 28.375 × 11.25″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6A066ADAS | 7,800 | 775 | 1 | 27.125 × 15.5 × 18.125″ |
| WL6A073ADAS | 8,500 | 1,600 | 2 | 43.625 × 15.5 × 18.125″ |
| WL6A094ADAS | 10,900 | 1,570 | 2 | 43.625 × 15.5 × 18.125″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| ASLA25061ADAS | 6,500 | 1,000 | 2 | 57 × 19.8125 × 9.1875″ |
| ASLA35073ADAS | 7,700 | 1,425 | 3 | 70 × 19.8125 × 9.1875″ |
| ASLA45098ADAS | 10,700 | 1,900 | 4 | 93 × 19.8125 × 9.1875″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
3/4 HP R-448A cooler system questions
How many BTU is a 3/4 HP R-448A walk-in cooler system?
The 4 R-448A condensing units in this class are rated 8,330 BTU/h at 90°F ambient and 8,020 BTU/h at 95°F, about 0.7 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 8,370 BTU/h.
What size walk-in cooler does a 3/4 HP system fit?
A 3/4 HP system is the standard refrigeration on our 6x8 and 8x8 walk-in cooler packages (7′6″ high, held at 35°F). We do the heat load calculation before anything is quoted.
Which 3/4 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBO080M4SDB on 208-230 V single phase; WBO080M4SEB on 208-230 V three phase. Outdoors only: WFO080M4SDA on 208-230 V single phase; WFO080M4SEA on 208-230 V three phase.
Is the 3/4 HP R-448A unit single phase, three phase or 460 V?
208-230 V single phase: WBO080M4SDB and WFO080M4SDA. 208-230 V three phase: WBO080M4SEB and WFO080M4SEA. No model in this class runs on 460 V.
How big and heavy is a 3/4 HP R-448A condensing unit?
Preassembled Remote, 4 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 8,330 BTU/h at 90°F and 8,020 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Need a 3/4 HP R-448A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 3/4 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.