FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-448A · Medium Temperature (Cooler)

1 HP R-448A walk-in cooler refrigeration system

Updated

A 1 HP system is the standard refrigeration on our 8x10 and 10x10 walk-in cooler packages (7′6″ high, held at 35°F). This class has 8 current R-448A condensing units at 1 HP, rated 9,380 to 9,680 BTU/h at 95°F ambient, with the 9 unit coolers matched to that capacity.

Outdoor remote refrigeration condensing unit of the type supplied with a 1 HP walk-in cooler system
1
Horsepower
9,680
BTU/h at 95°F ambient
8
Condensing units
9
Matched evaporators
8 models

1 HP R-448A condensing units

R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.

1 HP R-448A Medium Temperature (Cooler) condensing units, 8 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBO100M4SDB Preassembled Remote Indoor / Outdoor Scroll 9,740 9,380 208-230 · 1-ph 28.25 × 27.875 × 18.75″ 195 lb
WBO100M4SEB Preassembled Remote Indoor / Outdoor Scroll 9,740 9,380 208-230 · 3-ph 28.25 × 27.875 × 18.75″ 195 lb
WBO130E4SDB Preassembled Remote Indoor / Outdoor Scroll 10,030 9,680 208-230 · 1-ph 28.25 × 27.875 × 18.75″ 195 lb
WBO130E4SEB Preassembled Remote Indoor / Outdoor Scroll 10,030 9,680 208-230 · 3-ph 28.25 × 27.875 × 18.75″ 195 lb
WFO100M4SDA Preassembled Remote Outdoor Scroll 9,740 9,380 208-230 · 1-ph 28.25 × 27.875 × 18.75″ 195 lb
WFO100M4SEA Preassembled Remote Outdoor Scroll 9,740 9,380 208-230 · 3-ph 28.25 × 27.875 × 18.75″ 195 lb
WFO130E4SDA Preassembled Remote Outdoor Scroll 10,030 9,680 208-230 · 1-ph 28.25 × 27.875 × 18.75″ 195 lb
WFO130E4SEA Preassembled Remote Outdoor Scroll 10,030 9,680 208-230 · 3-ph 28.25 × 27.875 × 18.75″ 195 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 1 HP R-448A model fits your site

1 HP R-448A is rated up to 9,680 BTU/h at 95°F (about 0.8 tons) at 25°F suction, from 8 Preassembled Remote models. Compared with the 3/4 HP below it: 1,660 BTU/h more (21%), the same cabinet and weight. Of its 9 matched unit coolers, 7 also serve the 3/4 HP. The 1 1/4 HP above it is rated 12,140 BTU/h: a different cabinet, 205 lb against 195 lb here.

  • Preassembled Remote, 8 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 9,740 to 10,030 BTU/h at 90°F and 9,380 to 9,680 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
  • Indoors or outdoors. WBO100M4SDB and WBO130E4SDB on 208-230 V single phase; WBO100M4SEB and WBO130E4SEB on 208-230 V three phase.
  • Outdoors only. WFO100M4SDA and WFO130E4SDA on 208-230 V single phase; WFO100M4SEA and WFO130E4SEA on 208-230 V three phase.
  • Other refrigerant. The same 1 HP in R-454A (13 models, Next-Gen Mini-Con) is rated 9,350 to 10,230 BTU/h at 95°F, 6% more at the top of the range than R-448A, and weighs 195 lb. See the 1 HP R-454A walk-in cooler system.
9 unit coolers

Evaporators used with this system

A 1 HP R-448A condensing unit is matched to 9 medium-temperature unit coolers: 3 ultra low profile center mount, 3 low profile and 3 slim display case, rated 7,700 to 13,300 BTU/h.

Ultra low profile center mount, air defrost, 115 V: 3 models
ModelBTU/hCFMFansL × W × H
WE6A070ADAS 8,200 1,204 2 52 × 28.375 × 11.25″
WE6A084ADAS 9,900 1,144 2 52 × 28.375 × 11.25″
WE6A104ADAS 12,300 1,806 3 72 × 28.375 × 11.25″
Low profile, air defrost, 115 V: 3 models
ModelBTU/hCFMFansL × W × H
WL6A066ADAS 7,800 775 1 27.125 × 15.5 × 18.125″
WL6A073ADAS 8,500 1,600 2 43.625 × 15.5 × 18.125″
WL6A094ADAS 10,900 1,570 2 43.625 × 15.5 × 18.125″
Slim display case, air defrost, 115 V: 3 models
ModelBTU/hCFMFansL × W × H
ASLA35073ADAS 7,700 1,425 3 70 × 19.8125 × 9.1875″
ASLA45098ADAS 10,700 1,900 4 93 × 19.8125 × 9.1875″
ASLA55122ADAS 13,300 2,375 5 116 × 19.8125 × 9.1875″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

1 HP R-448A cooler system questions

How many BTU is a 1 HP R-448A walk-in cooler system?

The 8 R-448A condensing units in this class are rated 9,740 to 10,030 BTU/h at 90°F ambient and 9,380 to 9,680 BTU/h at 95°F, about 0.8 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 9,350 to 10,230 BTU/h.

What size walk-in cooler does a 1 HP system fit?

A 1 HP system is the standard refrigeration on our 8x10 and 10x10 walk-in cooler packages (7′6″ high, held at 35°F). We do the heat load calculation before anything is quoted.

Which 1 HP R-448A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBO100M4SDB and WBO130E4SDB on 208-230 V single phase; WBO100M4SEB and WBO130E4SEB on 208-230 V three phase. Outdoors only: WFO100M4SDA and WFO130E4SDA on 208-230 V single phase; WFO100M4SEA and WFO130E4SEA on 208-230 V three phase.

Is the 1 HP R-448A unit single phase, three phase or 460 V?

208-230 V single phase: WBO100M4SDB, WBO130E4SDB, WFO100M4SDA and WFO130E4SDA. 208-230 V three phase: WBO100M4SEB, WBO130E4SEB, WFO100M4SEA and WFO130E4SEA. No model in this class runs on 460 V.

How big and heavy is a 1 HP R-448A condensing unit?

Preassembled Remote, 8 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 9,740 to 10,030 BTU/h at 90°F and 9,380 to 9,680 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.

Need a 1 HP R-448A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 1 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration units

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 3/4 HP R-448A cooler  ·  1 HP R-448A freezer →

Call Now Get a Free Quote