1-1/4 HP R-448A walk-in cooler refrigeration system
Updated
1 1/4 HP is not a standard cooler package size (those run from 1/2 HP on a 6x6 to 1 1/2 HP on a 10x12). We choose it at quote when the heat load calls for about 12,100 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 4 current R-448A condensing units at 1-1/4 HP, rated 12,140 BTU/h at 95°F ambient, with the 10 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.
- Capacity. 12,580 BTU/h at 90°F ambient and 12,140 BTU/h at 95°F, about 1.0 tons of refrigeration.
- Next sizes. Smaller: 1 HP R-448A walk-in cooler system (9,380 to 9,680 BTU/h). Larger: 1-1/2 HP R-448A walk-in cooler system (13,690 BTU/h).
- Same horsepower in R-454A. 1-1/4 HP R-454A walk-in cooler system, 8 condensing units, 12,660 BTU/h at 95°F ambient.
1-1/4 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBO150E4SDA | Preassembled Remote | Indoor / Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 1-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
| WBO150E4SEA | Preassembled Remote | Indoor / Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 3-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
| WFO150E4SDA | Preassembled Remote | Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 1-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
| WFO150E4SEA | Preassembled Remote | Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 3-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
Manufacturer ratings at 25°F suction.
Which 1 1/4 HP R-448A model fits your site
1 1/4 HP R-448A is rated up to 12,140 BTU/h at 95°F (about 1.0 tons) at 25°F suction, from 4 Preassembled Remote models. Compared with the 1 HP below it: 2,460 BTU/h more (25%), a different cabinet, 205 lb against 195 lb. Of its 10 matched unit coolers, 5 also serve the 1 HP. The 1 1/2 HP above it is rated 13,690 BTU/h: the same cabinet, 210 lb against 205 lb here.
- Preassembled Remote, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 205 lb; 12,580 BTU/h at 90°F and 12,140 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBO150E4SDA on 208-230 V single phase; WBO150E4SEA on 208-230 V three phase.
- Outdoors only. WFO150E4SDA on 208-230 V single phase; WFO150E4SEA on 208-230 V three phase.
- Other refrigerant. The same 1 1/4 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 12,660 BTU/h at 95°F, 4% more at the top of the range than R-448A, and weighs 205 lb. See the 1-1/4 HP R-454A walk-in cooler system.
Evaporators used with this system
A 1-1/4 HP R-448A condensing unit is matched to 10 medium-temperature unit coolers: 4 ultra low profile center mount, 4 low profile and 2 slim display case, rated 9,900 to 16,600 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6A084ADAS | 9,900 | 1,144 | 2 | 52 × 28.375 × 11.25″ |
| WE6A104ADAS | 12,300 | 1,806 | 3 | 72 × 28.375 × 11.25″ |
| WE6A128ADAS | 15,100 | 1,716 | 3 | 72 × 28.375 × 11.25″ |
| WE6A141ADAS | 16,600 | 2,408 | 4 | 92 × 28.375 × 11.25″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6A094ADAS | 10,900 | 1,570 | 2 | 43.625 × 15.5 × 18.125″ |
| WL6A117ADAS | 13,600 | 1,550 | 2 | 43.625 × 15.5 × 18.125″ |
| WL6A130ADAS | 15,300 | 1,550 | 2 | 43.625 × 15.5 × 18.125″ |
| WL6A141ADAS | 16,300 | 2,355 | 3 | 60.125 × 15.5 × 18.125″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| ASLA45098ADAS | 10,700 | 1,900 | 4 | 93 × 19.8125 × 9.1875″ |
| ASLA55122ADAS | 13,300 | 2,375 | 5 | 116 × 19.8125 × 9.1875″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
1-1/4 HP R-448A cooler system questions
How many BTU is a 1 1/4 HP R-448A walk-in cooler system?
The 4 R-448A condensing units in this class are rated 12,580 BTU/h at 90°F ambient and 12,140 BTU/h at 95°F, about 1.0 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 12,660 BTU/h.
What size walk-in cooler does a 1 1/4 HP system fit?
1 1/4 HP is not a standard cooler package size (those run from 1/2 HP on a 6x6 to 1 1/2 HP on a 10x12). We choose it at quote when the heat load calls for about 12,100 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.
Which 1 1/4 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBO150E4SDA on 208-230 V single phase; WBO150E4SEA on 208-230 V three phase. Outdoors only: WFO150E4SDA on 208-230 V single phase; WFO150E4SEA on 208-230 V three phase.
Is the 1 1/4 HP R-448A unit single phase, three phase or 460 V?
208-230 V single phase: WBO150E4SDA and WFO150E4SDA. 208-230 V three phase: WBO150E4SEA and WFO150E4SEA. No model in this class runs on 460 V.
How big and heavy is a 1 1/4 HP R-448A condensing unit?
Preassembled Remote, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 205 lb; 12,580 BTU/h at 90°F and 12,140 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Need a 1 1/4 HP R-448A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 1 1/4 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.