1 HP R-454A walk-in freezer refrigeration system
Updated
A 1 HP R-454A system is the standard refrigeration on our 6x6 walk-in freezer package (insulated floor included, specified at -10°F). The next standard freezer, the 6x8, steps up to 1 1/2 HP. This class has 6 current R-454A condensing units at 1 HP, rated 2,850 BTU/h at 95°F ambient, with the 6 unit coolers matched to that capacity.
- Capacity. 2,960 BTU/h at 90°F ambient and 2,850 BTU/h at 95°F, about 0.2 tons of refrigeration.
- Next sizes. This is the smallest R-454A freezer class. Larger: 1-1/3 HP R-454A walk-in freezer system (3,820 BTU/h).
- Same horsepower in R-448A. 1 HP R-448A walk-in freezer system, 4 condensing units, 2,580 BTU/h at 95°F ambient.
1 HP R-454A condensing units
R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBON100L4ADA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 2,960 | 2,850 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WBON100L4AEA | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 2,960 | 2,850 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON100L4ADA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 2,960 | 2,850 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON100L4ADANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 2,960 | 2,850 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON100L4AEA | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 2,960 | 2,850 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| WFON100L4AEANT | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 2,960 | 2,850 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
Manufacturer ratings at -20°F suction.
Which 1 HP R-454A model fits your site
1 HP is the refrigeration on our standard 6x6 walk-in freezer, twice the 1/2 HP the same size cooler carries, because the freezer holds 0°F to -10°F. All six R-454A models are Next-Gen Mini-Con units in one cabinet with one rating, so the choice comes down to where the unit will sit and the power on site. It is the smallest R-454A freezer class we list, rated 2,960 BTU/h at 90°F and 2,850 at 95°F.
- Next-Gen Mini-Con, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 2,960 BTU/h at 90°F and 2,850 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBON100L4ADA on 208-230 V single phase; WBON100L4AEA on 208-230 V three phase.
- Outdoors only. WFON100L4ADA and WFON100L4ADANT on 208-230 V single phase; WFON100L4AEA and WFON100L4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- Other refrigerant. The same 1 HP in R-448A (4 models, Preassembled Remote) is rated 2,580 BTU/h at 95°F, 9% less at the top of the range than R-454A, and weighs 195 lb. See the 1 HP R-448A walk-in freezer system.
Evaporators used with this system
A 1 HP R-454A condensing unit is matched to 6 low-temperature unit coolers: 5 low profile and 1 center mount, rated 3,200 to 5,100 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAE6E045DDA | 4,500 | 602 | 1 | 36 × 28-3/8 × 11-1/4″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WAL4E032DDA | 3,200 | 800 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| WAL4E040DDA | 4,000 | 785 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| WAL6E042DDA | 4,200 | 800 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| WAL4E046DDA | 4,600 | 775 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| WAL6E051DDA | 5,100 | 785 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.
1 HP R-454A freezer system questions
How many BTU is a 1 HP R-454A walk-in freezer system?
The 6 R-454A condensing units in this class are rated 2,960 BTU/h at 90°F ambient and 2,850 BTU/h at 95°F, about 0.2 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-448A the same horsepower is rated 2,580 BTU/h.
What size walk-in freezer does a 1 HP system fit?
A 1 HP R-454A system is the standard refrigeration on our 6x6 walk-in freezer package (insulated floor included, specified at -10°F). The next standard freezer, the 6x8, steps up to 1 1/2 HP.
Which 1 HP R-454A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBON100L4ADA on 208-230 V single phase; WBON100L4AEA on 208-230 V three phase. Outdoors only: WFON100L4ADA and WFON100L4ADANT on 208-230 V single phase; WFON100L4AEA and WFON100L4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
Is the 1 HP R-454A unit single phase, three phase or 460 V?
208-230 V single phase: WBON100L4ADA, WFON100L4ADA and WFON100L4ADANT. 208-230 V three phase: WBON100L4AEA, WFON100L4AEA and WFON100L4AEANT. No model in this class runs on 460 V.
How big and heavy is a 1 HP R-454A condensing unit?
Next-Gen Mini-Con, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 2,960 BTU/h at 90°F and 2,850 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
What power do the unit coolers need with a 1 HP R-454A freezer system?
All six matched coils are listed at 208-230 V single phase with electric defrost, including when the condensing unit itself is a three phase model such as WBON100L4AEA. So a three phase building still needs 208-230 V single phase at the evaporator. Nothing in this class, unit or coil, runs on 460 V. Have your electrician confirm the circuits.
How much more does the 1 1/3 HP R-454A freezer system deliver?
It is rated 3,820 BTU/h at 95°F against 2,850 here, 970 more or about 34%. The two share one cabinet size, one weight and all six unit coolers, so the step costs nothing in floor or pad space.
Are the R-454A unit coolers the same models as the R-448A ones?
No. At 1 HP the R-454A list uses models starting WAL and WAE, and the R-448A list uses WL, WE and ASLE models; no model appears on both. The R-454A six are five low profile coils rated 3,200 to 5,100 BTU/h and one center mount, WAE6E045DDA, rated 4,500. If you are matching an existing coil, send us its model number with the quote request.
Need a 1 HP R-454A system sized for your walk-in freezer?
Send the inside dimensions and what it will store, tell us where the 1 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration units