FREE SHIPPING on every walk-in we quote  ·  Same-day quote
R-448A · Medium Temperature (Cooler)

1-1/2 HP R-448A walk-in cooler refrigeration system

Updated

A 1 1/2 HP R-448A system is the standard refrigeration on our 10x12 walk-in cooler package (7′6″ high, held at 35°F). Our smaller standard coolers use less: 1 HP on an 8x10 or 10x10, 3/4 HP on a 6x8 or 8x8 and 1/2 HP on a 6x6. This class has 4 current R-448A condensing units at 1-1/2 HP, rated 13,690 BTU/h at 95°F ambient, with the 9 unit coolers matched to that capacity.

Outdoor remote refrigeration condensing unit of the type supplied with a 1-1/2 HP walk-in cooler system
1-1/2
Horsepower
13,690
BTU/h at 95°F ambient
4
Condensing units
9
Matched evaporators
4 models

1-1/2 HP R-448A condensing units

R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.

1-1/2 HP R-448A Medium Temperature (Cooler) condensing units, 4 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBO180E4SDA Preassembled Remote Indoor / Outdoor Scroll 14,180 13,690 208-230 · 1-ph 28.25 × 39.875 × 18.75″ 210 lb
WBO180E4SEA Preassembled Remote Indoor / Outdoor Scroll 14,180 13,690 208-230 · 3-ph 28.25 × 39.875 × 18.75″ 210 lb
WFO180E4SDA Preassembled Remote Outdoor Scroll 14,180 13,690 208-230 · 1-ph 28.25 × 39.875 × 18.75″ 210 lb
WFO180E4SEA Preassembled Remote Outdoor Scroll 14,180 13,690 208-230 · 3-ph 28.25 × 39.875 × 18.75″ 210 lb

Manufacturer ratings at 25°F suction.

Choosing the model

Which 1 1/2 HP R-448A model fits your site

1 1/2 HP is the refrigeration on our standard 10x12 walk-in cooler, the largest of our six standard cooler packages. A box that grows past 10x12, takes glass doors or moves outdoors is sized again at quote. The four R-448A units here differ only by siting and phase: one Preassembled Remote cabinet, one rating.

  • Preassembled Remote, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 210 lb; 14,180 BTU/h at 90°F and 13,690 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
  • Indoors or outdoors. WBO180E4SDA on 208-230 V single phase; WBO180E4SEA on 208-230 V three phase.
  • Outdoors only. WFO180E4SDA on 208-230 V single phase; WFO180E4SEA on 208-230 V three phase.
  • Other refrigerant. The same 1 1/2 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 13,970 BTU/h at 95°F, 2% more at the top of the range than R-448A, and weighs 210 lb. See the 1-1/2 HP R-454A walk-in cooler system.
9 unit coolers

Evaporators used with this system

A 1-1/2 HP R-448A condensing unit is matched to 9 medium-temperature unit coolers: 4 low profile, 3 ultra low profile center mount and 2 slim display case, rated 12,300 to 18,800 BTU/h.

Ultra low profile center mount, air defrost, 115 V: 3 models
ModelBTU/hCFMFansL × W × H
WE6A104ADAS 12,300 1,806 3 72 × 28.375 × 11.25″
WE6A128ADAS 15,100 1,716 3 72 × 28.375 × 11.25″
WE6A141ADAS 16,600 2,408 4 92 × 28.375 × 11.25″
Low profile, air defrost, 115 V: 4 models
ModelBTU/hCFMFansL × W × H
WL6A117ADAS 13,600 1,550 2 43.625 × 15.5 × 18.125″
WL6A130ADAS 15,300 1,550 2 43.625 × 15.5 × 18.125″
WL6A141ADAS 16,300 2,355 3 60.125 × 15.5 × 18.125″
WL6A161ADAS 18,800 2,355 3 60.125 × 15.5 × 18.125″
Slim display case, air defrost, 115 V: 2 models
ModelBTU/hCFMFansL × W × H
ASLA55122ADAS 13,300 2,375 5 116 × 19.8125 × 9.1875″
ASLA65158ADAS 17,300 2,850 6 139 × 19.8125 × 9.1875″

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

Straight answers

1-1/2 HP R-448A cooler system questions

How many BTU is a 1 1/2 HP R-448A walk-in cooler system?

The 4 R-448A condensing units in this class are rated 14,180 BTU/h at 90°F ambient and 13,690 BTU/h at 95°F, about 1.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 13,970 BTU/h.

What size walk-in cooler does a 1 1/2 HP system fit?

A 1 1/2 HP R-448A system is the standard refrigeration on our 10x12 walk-in cooler package (7′6″ high, held at 35°F). Our smaller standard coolers use less: 1 HP on an 8x10 or 10x10, 3/4 HP on a 6x8 or 8x8 and 1/2 HP on a 6x6.

Which 1 1/2 HP R-448A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBO180E4SDA on 208-230 V single phase; WBO180E4SEA on 208-230 V three phase. Outdoors only: WFO180E4SDA on 208-230 V single phase; WFO180E4SEA on 208-230 V three phase.

Is the 1 1/2 HP R-448A unit single phase, three phase or 460 V?

208-230 V single phase: WBO180E4SDA and WFO180E4SDA. 208-230 V three phase: WBO180E4SEA and WFO180E4SEA. No model in this class runs on 460 V.

How big and heavy is a 1 1/2 HP R-448A condensing unit?

Preassembled Remote, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 210 lb; 14,180 BTU/h at 90°F and 13,690 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.

Need a 1 1/2 HP R-448A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 1 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.

Get a free quote All refrigeration systems

Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.

← 1-1/3 HP R-448A freezer  ·  1-1/2 HP R-448A freezer →

Call Now Get a Free Quote