1-1/2 HP R-448A walk-in cooler refrigeration system
Updated
A 1 1/2 HP R-448A system is the standard refrigeration on our 10x12 walk-in cooler package (7′6″ high, held at 35°F). Our smaller standard coolers use less: 1 HP on an 8x10 or 10x10, 3/4 HP on a 6x8 or 8x8 and 1/2 HP on a 6x6. This class has 4 current R-448A condensing units at 1-1/2 HP, rated 13,690 BTU/h at 95°F ambient, with the 9 unit coolers matched to that capacity.
- Capacity. 14,180 BTU/h at 90°F ambient and 13,690 BTU/h at 95°F, about 1.1 tons of refrigeration.
- Next sizes. Smaller: 1-1/4 HP R-448A walk-in cooler system (12,140 BTU/h). Larger: 2 HP R-448A walk-in cooler system (16,840 BTU/h).
- Same horsepower in R-454A. 1-1/2 HP R-454A walk-in cooler system, 8 condensing units, 13,970 BTU/h at 95°F ambient.
1-1/2 HP R-448A condensing units
R-448A is the non-flammable A1 blend that replaces R-404A. Compare R-448A and R-454A.
| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
|---|---|---|---|---|---|---|---|---|
| WBO180E4SDA | Preassembled Remote | Indoor / Outdoor | Scroll | 14,180 | 13,690 | 208-230 · 1-ph | 28.25 × 39.875 × 18.75″ | 210 lb |
| WBO180E4SEA | Preassembled Remote | Indoor / Outdoor | Scroll | 14,180 | 13,690 | 208-230 · 3-ph | 28.25 × 39.875 × 18.75″ | 210 lb |
| WFO180E4SDA | Preassembled Remote | Outdoor | Scroll | 14,180 | 13,690 | 208-230 · 1-ph | 28.25 × 39.875 × 18.75″ | 210 lb |
| WFO180E4SEA | Preassembled Remote | Outdoor | Scroll | 14,180 | 13,690 | 208-230 · 3-ph | 28.25 × 39.875 × 18.75″ | 210 lb |
Manufacturer ratings at 25°F suction.
Which 1 1/2 HP R-448A model fits your site
1 1/2 HP is the refrigeration on our standard 10x12 walk-in cooler, the largest of our six standard cooler packages. A box that grows past 10x12, takes glass doors or moves outdoors is sized again at quote. The four R-448A units here differ only by siting and phase: one Preassembled Remote cabinet, one rating.
- Preassembled Remote, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 210 lb; 14,180 BTU/h at 90°F and 13,690 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- Indoors or outdoors. WBO180E4SDA on 208-230 V single phase; WBO180E4SEA on 208-230 V three phase.
- Outdoors only. WFO180E4SDA on 208-230 V single phase; WFO180E4SEA on 208-230 V three phase.
- Other refrigerant. The same 1 1/2 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 13,970 BTU/h at 95°F, 2% more at the top of the range than R-448A, and weighs 210 lb. See the 1-1/2 HP R-454A walk-in cooler system.
Evaporators used with this system
A 1-1/2 HP R-448A condensing unit is matched to 9 medium-temperature unit coolers: 4 low profile, 3 ultra low profile center mount and 2 slim display case, rated 12,300 to 18,800 BTU/h.
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WE6A104ADAS | 12,300 | 1,806 | 3 | 72 × 28.375 × 11.25″ |
| WE6A128ADAS | 15,100 | 1,716 | 3 | 72 × 28.375 × 11.25″ |
| WE6A141ADAS | 16,600 | 2,408 | 4 | 92 × 28.375 × 11.25″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| WL6A117ADAS | 13,600 | 1,550 | 2 | 43.625 × 15.5 × 18.125″ |
| WL6A130ADAS | 15,300 | 1,550 | 2 | 43.625 × 15.5 × 18.125″ |
| WL6A141ADAS | 16,300 | 2,355 | 3 | 60.125 × 15.5 × 18.125″ |
| WL6A161ADAS | 18,800 | 2,355 | 3 | 60.125 × 15.5 × 18.125″ |
| Model | BTU/h | CFM | Fans | L × W × H |
|---|---|---|---|---|
| ASLA55122ADAS | 13,300 | 2,375 | 5 | 116 × 19.8125 × 9.1875″ |
| ASLA65158ADAS | 17,300 | 2,850 | 6 | 139 × 19.8125 × 9.1875″ |
Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.
1-1/2 HP R-448A cooler system questions
How many BTU is a 1 1/2 HP R-448A walk-in cooler system?
The 4 R-448A condensing units in this class are rated 14,180 BTU/h at 90°F ambient and 13,690 BTU/h at 95°F, about 1.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 13,970 BTU/h.
What size walk-in cooler does a 1 1/2 HP system fit?
A 1 1/2 HP R-448A system is the standard refrigeration on our 10x12 walk-in cooler package (7′6″ high, held at 35°F). Our smaller standard coolers use less: 1 HP on an 8x10 or 10x10, 3/4 HP on a 6x8 or 8x8 and 1/2 HP on a 6x6.
Which 1 1/2 HP R-448A condensing unit goes indoors, and which outdoors?
Indoors or outdoors: WBO180E4SDA on 208-230 V single phase; WBO180E4SEA on 208-230 V three phase. Outdoors only: WFO180E4SDA on 208-230 V single phase; WFO180E4SEA on 208-230 V three phase.
Is the 1 1/2 HP R-448A unit single phase, three phase or 460 V?
208-230 V single phase: WBO180E4SDA and WFO180E4SDA. 208-230 V three phase: WBO180E4SEA and WFO180E4SEA. No model in this class runs on 460 V.
How big and heavy is a 1 1/2 HP R-448A condensing unit?
Preassembled Remote, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 210 lb; 14,180 BTU/h at 90°F and 13,690 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
Need a 1 1/2 HP R-448A system sized for your walk-in cooler?
Send the inside dimensions and what it will store, tell us where the 1 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.
Get a free quote All refrigeration systems
Condensing units UL and cUL listed; unit coolers also NSF approved and AWEF certified. Listing details.