6 current R-454A condensing units at 1 HP, rated 2,850 BTU/h at 95°F ambient, with the 6 unit coolers matched to that capacity. Sized for a walk-in freezer holding 0°F to -10°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 1 HP walk-in freezer system
1
Horsepower
2,850
BTU/h at 95°F ambient
6
Condensing units
6
Matched evaporators
6 models

1 HP R-454A condensing units

R-454A is the current refrigerant for this class. R-454A is an A2L, mildly flammable, lower-GWP refrigerant — installation follows the A2L requirements in the manufacturer’s instructions.

1 HP R-454A Low Temperature (Freezer) condensing units — 6 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBON100L4ADA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 2,960 2,850 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WBON100L4AEA Next-Gen Mini-Con Indoor / Outdoor Scroll · Non-Flooded 2,960 2,850 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100L4ADA Next-Gen Mini-Con Outdoor Scroll · Flooded 2,960 2,850 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100L4ADANT Next-Gen Mini-Con Outdoor Scroll · Flooded 2,960 2,850 208-230/1/60 · 1-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100L4AEA Next-Gen Mini-Con Outdoor Scroll · Flooded 2,960 2,850 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb
WFON100L4AEANT Next-Gen Mini-Con Outdoor Scroll · Flooded 2,960 2,850 208-230/3/60 · 3-ph 28-1/4 × 27-7/8 × 18-3/4″ 195 lb

Ratings are the manufacturer’s published capacities at -20°F suction for the ambient shown. A dash means the figure is not published for that model — call 954-237-6753 and we will confirm it.

6 unit coolers

Evaporators used with this system

These are the R-454A low-temperature unit coolers used with a 1 HP condensing unit. The evaporator is what decides the room: a low-temperature coil makes it a freezer, a medium-temperature coil makes it a cooler.

R-454A Low Temperature (Freezer) unit coolers matched to 1 HP — 6 models
ModelSeries BTU/hCFMFans DefrostVoltage L × W × H
WAE6E045DDA Center Mount Unit Cooler 4,500 602 1 Electric 208-230/1/60 36 × 28-3/8 × 11-1/4″
WAL4E032DDA Low Profile Walk-In Unit Cooler 3,200 800 1 Electric 208-230/1/60 27-1/8 × 15-1/2 × 18-1/8″
WAL4E040DDA Low Profile Walk-In Unit Cooler 4,000 785 1 Electric 208-230/1/60 27-1/8 × 15-1/2 × 18-1/8″
WAL6E042DDA Low Profile Walk-In Unit Cooler 4,200 800 1 Electric 208-230/1/60 27-1/8 × 15-1/2 × 18-1/8″
WAL4E046DDA Low Profile Walk-In Unit Cooler 4,600 775 1 Electric 208-230/1/60 27-1/8 × 15-1/2 × 18-1/8″
WAL6E051DDA Low Profile Walk-In Unit Cooler 5,100 785 1 Electric 208-230/1/60 27-1/8 × 15-1/2 × 18-1/8″

Grouped by published capacity against this horsepower class. Note that the two ratings are published at different conditions — the condensing unit at the ambient and suction temperature shown above, the unit cooler at its rated temperature difference — so the BTU figures are not meant to be read against each other one for one. On low-temperature systems the coil is deliberately sized for a small temperature difference, so its rating normally reads higher than the condensing unit’s. The final evaporator for your job depends on the box size, the door traffic, the product going in and the ambient around it — we do that calculation for you before anything is quoted. Call 954-237-6753.

Need this system sized for your box?

Send us the inside dimensions and what you are storing. You get a drawing and a price, not a runaround.

Get a free quote All refrigeration systems

Condensing units are UL and cUL listed for indoor or outdoor use. Unit coolers are UL and cUL listed, NSF approved for use in food preparation areas, and AWEF certified for walk-in coolers and freezers in boxes under 3,000 sq. ft.

← 1 HP R-454A cooler  ·  1-1/4 HP R-454A cooler →

Call Now Get a Free Quote