title: "6 HP R-454A Walk-In Cooler Refrigeration System | Frigid Coolers LLC"
description: "6 HP R-454A walk-in cooler system, sized at quote from your heat load: 42,680 to 50,770 BTU/h at 95°F, 9 condensing units, 26 matched evaporators."
url: "https://www.frigidcoolers.com/refrigeration/6-hp-r-454a-walk-in-cooler-refrigeration-system"
language: "en"
published: "2026-10-07"
updated: "2026-11-22T12:50:04+00:00"
---

# 6 HP R-454A walk-in cooler refrigeration system

Updated November 22, 2026

6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 50,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 9 current R-454A condensing units at 6 HP, rated 42,680 to 50,770 BTU/h at 95°F ambient, with the 26 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

- **Capacity.** 44,200 to 52,580 BTU/h at 90°F ambient and 42,680 to 50,770 BTU/h at 95°F, about 3.6 to 4.2 tons of refrigeration.
- **Next sizes.** Smaller: [5 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/5-hp-r-454a-walk-in-cooler-refrigeration-system) (36,490 to 43,410 BTU/h). This is the largest R-454A cooler class.
- **Same horsepower in R-448A.** [6 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/6-hp-r-448a-walk-in-cooler-refrigeration-system), 6 condensing units, 35,080 to 47,250 BTU/h at 95°F ambient.

- **6** Horsepower
- **50,770** BTU/h at 95°F ambient
- **9** Condensing units
- **26** Matched evaporators

## 6 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*6 HP R-454A Medium Temperature (Cooler) condensing units, 9 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBOS006E4AEA** | Next-Gen II | Indoor / Outdoor | Scroll · Non-Flooded | 44,200 | 42,680 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WBOS006E4AGA** | Next-Gen II | Indoor / Outdoor | Scroll · Non-Flooded | 44,200 | 42,680 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WBON600E4AEA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 52,580 | 50,770 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| **WBON600E4AGA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 52,580 | 50,770 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| **WFOS006E4AEA** | Next-Gen II | Outdoor | Scroll · Flooded | 44,200 | 42,680 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WFOS006E4AGA** | Next-Gen II | Outdoor | Scroll · Flooded | 44,200 | 42,680 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WFON600E4AEA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 52,580 | 50,770 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| **WFON600E4AEANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 52,580 | 50,770 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |
| **WFON600E4AGA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 52,580 | 50,770 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 405 lb |

Manufacturer ratings at 25°F suction.

## Which 6 HP R-454A model fits your site

6 HP R-454A is rated up to 50,770 BTU/h at 95°F (about 4.2 tons) at 25°F suction, from 9 models in 2 series. Compared with the 5 HP below it: 7,360 BTU/h more (17%), 405 to 710 lb against 383 to 710 lb. It has no 208-230 V single phase model, which the 5 HP has. Of its 26 matched unit coolers, 20 also serve the 5 HP.

- **Next-Gen II**, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 44,200 BTU/h at 90°F and 42,680 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
- **Next-Gen Mini-Con**, 5 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 52,580 BTU/h at 90°F and 50,770 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
- **Indoors or outdoors.** WBOS006E4AEA and WBON600E4AEA on 208-230 V three phase; WBOS006E4AGA and WBON600E4AGA on 460 V three phase.
- **Outdoors only.** WFOS006E4AEA, WFON600E4AEA and WFON600E4AEANT on 208-230 V three phase; WFOS006E4AGA and WFON600E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- **Other refrigerant.** The same 6 HP in R-448A (6 models, Next-Gen II Scroll and Preassembled Remote) is rated 35,080 to 47,250 BTU/h at 95°F, 7% less at the top of the range than R-454A, and weighs 405 to 710 lb. See the [6 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/6-hp-r-448a-walk-in-cooler-refrigeration-system).

## Evaporators used with this system

A 6 HP R-454A condensing unit is matched to 26 medium-temperature unit coolers: 20 medium profile and 6 low profile, rated 37,500 to 66,800 BTU/h.

*Low profile, air defrost: 6 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAL6A375ADA** 115/1/60 **WAL6A375DDA** 208-230/1/60 | 37,500 | 3,875 | 5 | 93-1/8 × 15-1/2 × 18-1/8″ |
| **WAL6A404ADA** 115/1/60 **WAL6A404DDA** 208-230/1/60 | 40,400 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6A477ADA** 115/1/60 **WAL6A477DDA** 208-230/1/60 | 47,700 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |

*Medium profile, air defrost: 9 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM6A448ADA** 115/1/60 **WAM6A448DDA** 208-230/1/60 **WAM6A448FDA** 460/1/60 | 44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6A540ADA** 115/1/60 **WAM6A540DDA** 208-230/1/60 **WAM6A540FDA** 460/1/60 | 54,000 | 5,900 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6A668ADA** 115/1/60 **WAM6A668DDA** 208-230/1/60 **WAM6A668FDA** 460/1/60 | 66,800 | 9,580 | 3 | 113-9/16 × 21-5/16 × 33-7/8″ |

*Medium profile, electric defrost: 11 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM6D447DDA** 208-230/1/60 **WAM6D447EDA** 208-230/3/60 **WAM6D447FDA** 460/1/60 **WAM6D447GDA** 460/3/60 | 44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6D539DDA** 208-230/1/60 **WAM6D539EDA** 208-230/3/60 **WAM6D539FDA** 460/1/60 **WAM6D539GDA** 460/3/60 | 54,000 | 5,900 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6D667EDA** 208-230/3/60 **WAM6D667FDA** 460/1/60 **WAM6D667GDA** 460/3/60 | 66,800 | 9,580 | 3 | 113-9/16 × 21-5/16 × 33-7/8″ |

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

## 6 HP R-454A cooler system questions

### How many BTU is a 6 HP R-454A walk-in cooler system?

The 9 R-454A condensing units in this class are rated 44,200 to 52,580 BTU/h at 90°F ambient and 42,680 to 50,770 BTU/h at 95°F, about 3.6 to 4.2 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 35,080 to 47,250 BTU/h.

### What size walk-in cooler does a 6 HP system fit?

6 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 50,800 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

### Which 6 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBOS006E4AEA and WBON600E4AEA on 208-230 V three phase; WBOS006E4AGA and WBON600E4AGA on 460 V three phase. Outdoors only: WFOS006E4AEA, WFON600E4AEA and WFON600E4AEANT on 208-230 V three phase; WFOS006E4AGA and WFON600E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

### Is the 6 HP R-454A unit single phase, three phase or 460 V?

208-230 V three phase: WBOS006E4AEA, WBON600E4AEA, WFOS006E4AEA, WFON600E4AEA and WFON600E4AEANT. 460 V three phase: WBOS006E4AGA, WBON600E4AGA, WFOS006E4AGA and WFON600E4AGA. No model in this class runs on single phase.

### How big and heavy is a 6 HP R-454A condensing unit?

**Next-Gen II**, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 44,200 BTU/h at 90°F and 42,680 BTU/h at 95°F; 208-230 V three phase and 460 V three phase. **Next-Gen Mini-Con**, 5 models: cabinet 33 × 43 7/8 × 35 in., 405 lb; 52,580 BTU/h at 90°F and 50,770 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.

## Need a 6 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 6 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 5 HP R-454A freezer](https://www.frigidcoolers.com/refrigeration/5-hp-r-454a-walk-in-freezer-refrigeration-system) · [6 HP R-454A freezer →](https://www.frigidcoolers.com/refrigeration/6-hp-r-454a-walk-in-freezer-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/6-hp-r-454a-walk-in-cooler-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt