# 5 HP R-448A walk-in cooler refrigeration system

Updated November 22, 2026

5 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 43,200 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 8 current R-448A condensing units at 5 HP, rated 35,180 to 43,160 BTU/h at 95°F ambient, with the 5 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

- **Capacity.** 36,460 to 45,040 BTU/h at 90°F ambient and 35,180 to 43,160 BTU/h at 95°F, about 2.9 to 3.6 tons of refrigeration.
- **Next sizes.** Smaller: [4-1/2 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/4-1-2-hp-r-448a-walk-in-cooler-refrigeration-system) (39,190 BTU/h). Larger: [6 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/6-hp-r-448a-walk-in-cooler-refrigeration-system) (35,080 to 47,250 BTU/h).
- **Same horsepower in R-454A.** [5 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/5-hp-r-454a-walk-in-cooler-refrigeration-system), 12 condensing units, 36,490 to 43,410 BTU/h at 95°F ambient.

- **5** Horsepower
- **43,160** BTU/h at 95°F ambient
- **8** Condensing units
- **5** Matched evaporators

## 5 HP R-448A condensing units

R-448A is the non-flammable A1 blend that replaces R-404A. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*5 HP R-448A Medium Temperature (Cooler) condensing units, 8 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBOS05E4SEB** | Next-Gen II Scroll | Indoor / Outdoor | Scroll · Non-Flooded | 36,460 | 35,180 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WBOS05E4SGB** | Next-Gen II Scroll | Indoor / Outdoor | Scroll · Non-Flooded | 36,460 | 35,180 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WBO500E4SDB** | Preassembled Remote | Indoor / Outdoor | Scroll | 45,040 | 43,160 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 383 lb |
| **WBO500E4SEB** | Preassembled Remote | Indoor / Outdoor | Scroll | 45,040 | 43,160 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 383 lb |
| **WFOS05E4SEA** | Next-Gen II Scroll | Outdoor | Scroll · Flooded | 36,460 | 35,180 | 208/230/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WFOS05E4SGA** | Next-Gen II Scroll | Outdoor | Scroll · Flooded | 36,460 | 35,180 | 460/3/60 · 3-ph | 49 × 38-5/16 × 36-3/8″ | 710 lb |
| **WFO500E4SDA** | Preassembled Remote | Outdoor | Scroll | 45,040 | 43,160 | 208-230 · 1-ph | 33 × 43.875 × 35″ | 383 lb |
| **WFO500E4SEA** | Preassembled Remote | Outdoor | Scroll | 45,040 | 43,160 | 208-230 · 3-ph | 33 × 43.875 × 35″ | 383 lb |

Manufacturer ratings at 25°F suction.

## Which 5 HP R-448A model fits your site

5 HP R-448A is rated up to 43,160 BTU/h at 95°F (about 3.6 tons) at 25°F suction, from 8 models in 2 series. Compared with the 4 1/2 HP below it: 3,970 BTU/h more (10%), 383 to 710 lb against 375 lb. It adds 460 V three phase, which the 4 1/2 HP does not offer. All 5 of its matched unit coolers also serve the 4 1/2 HP. The 6 HP above it is rated 47,250 BTU/h: 405 to 710 lb against 383 to 710 lb here.

- **Next-Gen II Scroll**, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 36,460 BTU/h at 90°F and 35,180 BTU/h at 95°F; 208-230 V three phase and 460 V three phase.
- **Preassembled Remote**, 4 models: cabinet 33 × 43 7/8 × 35 in., 383 lb; 45,040 BTU/h at 90°F and 43,160 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- **Indoors or outdoors.** WBO500E4SDB on 208-230 V single phase; WBOS05E4SEB and WBO500E4SEB on 208-230 V three phase; WBOS05E4SGB on 460 V three phase.
- **Outdoors only.** WFO500E4SDA on 208-230 V single phase; WFOS05E4SEA and WFO500E4SEA on 208-230 V three phase; WFOS05E4SGA on 460 V three phase.
- **Other refrigerant.** The same 5 HP in R-454A (12 models, Next-Gen II and Next-Gen Mini-Con) is rated 36,490 to 43,410 BTU/h at 95°F, 1% more at the top of the range than R-448A, and weighs 383 to 710 lb. See the [5 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/5-hp-r-454a-walk-in-cooler-refrigeration-system).

## Evaporators used with this system

A 5 HP R-448A condensing unit is matched to 5 medium-temperature unit coolers: 4 low profile and 1 ultra low profile center mount, rated 30,400 to 45,900 BTU/h.

*Ultra low profile center mount, air defrost, 115 V: 1 model*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WE6A258ADAS** | 30,400 | 3,150 | 5 | 112 × 28.375 × 13.75″ |

*Low profile, air defrost, 115 V: 4 models*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WL6A260ADAS** | 30,400 | 3,100 | 4 | 76.625 × 15.5 × 18.125″ |
| **WL6A295ADAS** | 36,100 | 3,875 | 5 | 93.125 × 15.5 × 18.125″ |
| **WL6A330ADAS** | 38,800 | 4,650 | 6 | 109.625 × 15.5 × 18.125″ |
| **WL6A390ADAS** | 45,900 | 4,650 | 6 | 109.625 × 15.5 × 18.125″ |

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

## 5 HP R-448A cooler system questions

### How many BTU is a 5 HP R-448A walk-in cooler system?

The 8 R-448A condensing units in this class are rated 36,460 to 45,040 BTU/h at 90°F ambient and 35,180 to 43,160 BTU/h at 95°F, about 2.9 to 3.6 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 36,490 to 43,410 BTU/h.

### What size walk-in cooler does a 5 HP system fit?

5 HP is above our standard cooler packages, the largest of which carries 1 1/2 HP on a 10x12. We choose it at quote when the heat load calls for about 43,200 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

### Which 5 HP R-448A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBO500E4SDB on 208-230 V single phase; WBOS05E4SEB and WBO500E4SEB on 208-230 V three phase; WBOS05E4SGB on 460 V three phase. Outdoors only: WFO500E4SDA on 208-230 V single phase; WFOS05E4SEA and WFO500E4SEA on 208-230 V three phase; WFOS05E4SGA on 460 V three phase.

### Is the 5 HP R-448A unit single phase, three phase or 460 V?

208-230 V single phase: WBO500E4SDB and WFO500E4SDA. 208-230 V three phase: WBOS05E4SEB, WBO500E4SEB, WFOS05E4SEA and WFO500E4SEA. 460 V three phase: WBOS05E4SGB and WFOS05E4SGA.

### How big and heavy is a 5 HP R-448A condensing unit?

**Next-Gen II Scroll**, 4 models: cabinet 49 × 38 5/16 × 36 3/8 in., 710 lb; 36,460 BTU/h at 90°F and 35,180 BTU/h at 95°F; 208-230 V three phase and 460 V three phase. **Preassembled Remote**, 4 models: cabinet 33 × 43 7/8 × 35 in., 383 lb; 45,040 BTU/h at 90°F and 43,160 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.

## Need a 5 HP R-448A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 5 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 4-1/2 HP R-448A cooler](https://www.frigidcoolers.com/refrigeration/4-1-2-hp-r-448a-walk-in-cooler-refrigeration-system) · [5 HP R-448A freezer →](https://www.frigidcoolers.com/refrigeration/5-hp-r-448a-walk-in-freezer-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/5-hp-r-448a-walk-in-cooler-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt