# 4-1/2 HP R-454A walk-in cooler refrigeration system

Updated November 21, 2026

A walk-in cooler that needs about 37,000 BTU/h at 95°F gets 4 1/2 HP at quote, three times the 1 1/2 HP of our standard 10x12: large custom rooms, long glass door walls and coolers outdoors. This class has 8 current R-454A condensing units at 4-1/2 HP, rated 37,170 BTU/h at 95°F ambient, with the 24 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

- **Capacity.** 38,710 BTU/h at 90°F ambient and 37,170 BTU/h at 95°F, about 3.1 tons of refrigeration.
- **Next sizes.** Smaller: [4 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/4-hp-r-454a-walk-in-cooler-refrigeration-system) (32,590 to 33,420 BTU/h). Larger: [5 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/5-hp-r-454a-walk-in-cooler-refrigeration-system) (36,490 to 43,410 BTU/h).
- **Same horsepower in R-448A.** [4-1/2 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/4-1-2-hp-r-448a-walk-in-cooler-refrigeration-system), 4 condensing units, 39,190 BTU/h at 95°F ambient.

- **4-1/2** Horsepower
- **37,170** BTU/h at 95°F ambient
- **8** Condensing units
- **24** Matched evaporators

## 4-1/2 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*4-1/2 HP R-454A Medium Temperature (Cooler) condensing units, 8 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBON450E4ADA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 38,710 | 37,170 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WBON450E4AEA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 38,710 | 37,170 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WBON450E4AGA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 38,710 | 37,170 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WFON450E4ADA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WFON450E4ADANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WFON450E4AEA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WFON450E4AEANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |
| **WFON450E4AGA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 38,710 | 37,170 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 375 lb |

Manufacturer ratings at 25°F suction.

## Which 4 1/2 HP R-454A model fits your site

4 1/2 HP R-454A comes only as the Next-Gen Mini-Con: eight models at 375 lb in the 33 × 43 7/8 × 35 in. cabinet, rated 37,170 BTU/h at 95°F, about 3.1 tons. The 4 HP and 5 HP on either side also come as a Next-Gen II at 700 lb or more; this size does not, and it still out-rates the 5 HP Next-Gen II (36,490 BTU/h). It covers single phase, three phase and 460 V. The 4 1/2 HP R-448A stops at 208-230 V, though it is rated about 5% higher.

- **Next-Gen Mini-Con**, 8 models: cabinet 33 × 43 7/8 × 35 in., 375 lb; 38,710 BTU/h at 90°F and 37,170 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- **Indoors or outdoors.** WBON450E4ADA on 208-230 V single phase; WBON450E4AEA on 208-230 V three phase; WBON450E4AGA on 460 V three phase.
- **Outdoors only.** WFON450E4ADA and WFON450E4ADANT on 208-230 V single phase; WFON450E4AEA and WFON450E4AEANT on 208-230 V three phase; WFON450E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- **Other refrigerant.** The same 4 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 39,190 BTU/h at 95°F, 5% more at the top of the range than R-454A, and weighs 375 lb. See the [4-1/2 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/4-1-2-hp-r-448a-walk-in-cooler-refrigeration-system).

## Evaporators used with this system

A 4-1/2 HP R-454A condensing unit is matched to 24 medium-temperature unit coolers: 14 medium profile, 8 low profile and 2 center mount, rated 31,600 to 47,700 BTU/h.

*Center mount, air defrost: 2 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAE6A316ADA** 115/1/60 **WAE6A316DDA** 208-230/1/60 | 31,600 | 3,150 | 5 | 116 × 28-3/8 × 13-3/4″ |

*Low profile, air defrost: 8 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAL6A316ADA** 115/1/60 **WAL6A316DDA** 208-230/1/60 | 31,600 | 3,199 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6A375ADA** 115/1/60 **WAL6A375DDA** 208-230/1/60 | 37,500 | 3,875 | 5 | 93-1/8 × 15-1/2 × 18-1/8″ |
| **WAL6A404ADA** 115/1/60 **WAL6A404DDA** 208-230/1/60 | 40,400 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6A477ADA** 115/1/60 **WAL6A477DDA** 208-230/1/60 | 47,700 | 4,650 | 6 | 109-5/8 × 15-1/2 × 18-1/8″ |

*Medium profile, air defrost: 6 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM6A336ADA** 115/1/60 **WAM6A336DDA** 208-230/1/60 **WAM6A336FDA** 460/1/60 | 33,600 | 6,950 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6A448ADA** 115/1/60 **WAM6A448DDA** 208-230/1/60 **WAM6A448FDA** 460/1/60 | 44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |

*Medium profile, electric defrost: 8 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM6D335DDA** 208-230/1/60 **WAM6D335EDA** 208-230/3/60 **WAM6D335FDA** 460/1/60 **WAM6D335GDA** 460/3/60 | 33,600 | 6,950 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6D447DDA** 208-230/1/60 **WAM6D447EDA** 208-230/3/60 **WAM6D447FDA** 460/1/60 **WAM6D447GDA** 460/3/60 | 44,800 | 6,380 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

## 4-1/2 HP R-454A cooler system questions

### How many BTU is a 4 1/2 HP R-454A walk-in cooler system?

The 8 R-454A condensing units in this class are rated 38,710 BTU/h at 90°F ambient and 37,170 BTU/h at 95°F, about 3.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 39,190 BTU/h.

### What size walk-in cooler does a 4 1/2 HP system fit?

A walk-in cooler that needs about 37,000 BTU/h at 95°F gets 4 1/2 HP at quote, three times the 1 1/2 HP of our standard 10x12: large custom rooms, long glass door walls and coolers outdoors.

### Which 4 1/2 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON450E4ADA on 208-230 V single phase; WBON450E4AEA on 208-230 V three phase; WBON450E4AGA on 460 V three phase. Outdoors only: WFON450E4ADA and WFON450E4ADANT on 208-230 V single phase; WFON450E4AEA and WFON450E4AEANT on 208-230 V three phase; WFON450E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

### Is the 4 1/2 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON450E4ADA, WFON450E4ADA and WFON450E4ADANT. 208-230 V three phase: WBON450E4AEA, WFON450E4AEA and WFON450E4AEANT. 460 V three phase: WBON450E4AGA and WFON450E4AGA.

### How big and heavy is a 4 1/2 HP R-454A condensing unit?

**Next-Gen Mini-Con**, 8 models: cabinet 33 × 43 7/8 × 35 in., 375 lb; 38,710 BTU/h at 90°F and 37,170 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

### Is a 4 1/2 HP R-454A unit bigger than a 5 HP Next-Gen II?

By rating, yes: 37,170 BTU/h at 95°F against 36,490 for the 5 HP Next-Gen II, at 375 lb against 710 lb. The 5 HP Next-Gen Mini-Con is the larger one at 43,410 BTU/h and 383 lb. Horsepower is a nominal size, so compare BTU/h.

## Need a 4 1/2 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 4 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 4 HP R-454A freezer](https://www.frigidcoolers.com/refrigeration/4-hp-r-454a-walk-in-freezer-refrigeration-system) · [5 HP R-454A cooler →](https://www.frigidcoolers.com/refrigeration/5-hp-r-454a-walk-in-cooler-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/4-1-2-hp-r-454a-walk-in-cooler-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt