# 3/4 HP R-454A walk-in cooler refrigeration system

Updated November 21, 2026

A 3/4 HP system is the standard refrigeration on our 6x8 and 8x8 walk-in cooler packages (7′6″ high, held at 35°F). This class has 6 current R-454A condensing units at 3/4 HP, rated 8,370 BTU/h at 95°F ambient, with the 10 unit coolers matched to that capacity.

- **Capacity.** 8,740 BTU/h at 90°F ambient and 8,370 BTU/h at 95°F, about 0.7 tons of refrigeration.
- **Next sizes.** Smaller: [1/2 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/1-2-hp-r-454a-walk-in-cooler-refrigeration-system) (7,120 BTU/h). Larger: [1 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/1-hp-r-454a-walk-in-cooler-refrigeration-system) (9,350 to 10,230 BTU/h).
- **Same horsepower in R-448A.** [3/4 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/3-4-hp-r-448a-walk-in-cooler-refrigeration-system), 4 condensing units, 8,020 BTU/h at 95°F ambient.

- **3/4** Horsepower
- **8,370** BTU/h at 95°F ambient
- **6** Condensing units
- **10** Matched evaporators

## 3/4 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*3/4 HP R-454A Medium Temperature (Cooler) condensing units, 6 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBON080M4ADA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 8,740 | 8,370 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| **WBON080M4AEA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 8,740 | 8,370 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| **WFON080M4ADA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,740 | 8,370 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| **WFON080M4ADANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,740 | 8,370 | 208-230/1/60 · 1-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| **WFON080M4AEA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,740 | 8,370 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |
| **WFON080M4AEANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 8,740 | 8,370 | 208-230/3/60 · 3-ph | 28-1/4 × 27-7/8 × 18-3/4″ | 195 lb |

Manufacturer ratings at 25°F suction.

## Which 3/4 HP R-454A model fits your site

3/4 HP R-454A is rated up to 8,370 BTU/h at 95°F (about 0.7 tons) at 25°F suction, from 6 Next-Gen Mini-Con models. Compared with the 1/2 HP below it: 1,250 BTU/h more (18%), the same cabinet and weight. Of its 10 matched unit coolers, 6 also serve the 1/2 HP. The 1 HP above it is rated 10,230 BTU/h: the same cabinet and weight.

- **Next-Gen Mini-Con**, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 8,740 BTU/h at 90°F and 8,370 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- **Indoors or outdoors.** WBON080M4ADA on 208-230 V single phase; WBON080M4AEA on 208-230 V three phase.
- **Outdoors only.** WFON080M4ADA and WFON080M4ADANT on 208-230 V single phase; WFON080M4AEA and WFON080M4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- **Other refrigerant.** The same 3/4 HP in R-448A (4 models, Preassembled Remote) is rated 8,020 BTU/h at 95°F, 4% less at the top of the range than R-454A, and weighs 195 lb. See the [3/4 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/3-4-hp-r-448a-walk-in-cooler-refrigeration-system).

## Evaporators used with this system

A 3/4 HP R-454A condensing unit is matched to 10 medium-temperature unit coolers: 6 low profile and 4 center mount, rated 8,100 to 11,300 BTU/h.

*Center mount, air defrost: 4 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAE6A085ADA** 115/1/60 **WAE6A085DDA** 208-230/1/60 | 8,500 | 1,204 | 2 | 56 × 28-3/8 × 11-1/4″ |
| **WAE6A103ADA** 115/1/60 **WAE6A103DDA** 208-230/1/60 | 10,300 | 1,144 | 2 | 56 × 28-3/8 × 11-1/4″ |

*Low profile, air defrost: 6 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAL6A081ADA** 115/1/60 **WAL6A081DDA** 208-230/1/60 | 8,100 | 775 | 1 | 27-1/8 × 15-1/2 × 18-1/8″ |
| **WAL6A088ADA** 115/1/60 **WAL6A088DDA** 208-230/1/60 | 8,800 | 1,600 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6A113ADA** 115/1/60 **WAL6A113DDA** 208-230/1/60 | 11,300 | 1,570 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

## 3/4 HP R-454A cooler system questions

### How many BTU is a 3/4 HP R-454A walk-in cooler system?

The 6 R-454A condensing units in this class are rated 8,740 BTU/h at 90°F ambient and 8,370 BTU/h at 95°F, about 0.7 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-448A the same horsepower is rated 8,020 BTU/h.

### What size walk-in cooler does a 3/4 HP system fit?

A 3/4 HP system is the standard refrigeration on our 6x8 and 8x8 walk-in cooler packages (7′6″ high, held at 35°F). We do the heat load calculation before anything is quoted.

### Which 3/4 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON080M4ADA on 208-230 V single phase; WBON080M4AEA on 208-230 V three phase. Outdoors only: WFON080M4ADA and WFON080M4ADANT on 208-230 V single phase; WFON080M4AEA and WFON080M4AEANT on 208-230 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

### Is the 3/4 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON080M4ADA, WFON080M4ADA and WFON080M4ADANT. 208-230 V three phase: WBON080M4AEA, WFON080M4AEA and WFON080M4AEANT. No model in this class runs on 460 V.

### How big and heavy is a 3/4 HP R-454A condensing unit?

**Next-Gen Mini-Con**, 6 models: cabinet 28 1/4 × 27 7/8 × 18 3/4 in., 195 lb; 8,740 BTU/h at 90°F and 8,370 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.

### How do the R-454A and R-448A versions of 3/4 HP compare?

R-454A is rated 8,370 BTU/h at 95°F against 8,020, which is 350 more or about 4%, in a cabinet of the same size at the same 195 lb. It comes in six models against four, with 10 matched unit coolers against 8.

### Do the 3/4 HP unit coolers also serve the 1 HP R-454A system?

All 10 do. The 1 HP class adds WAE6A128 and WAL6A141, each at 115 V and 208-230 V.

## Need a 3/4 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 3/4 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 1/2 HP R-454A cooler](https://www.frigidcoolers.com/refrigeration/1-2-hp-r-454a-walk-in-cooler-refrigeration-system) · [1 HP R-454A cooler →](https://www.frigidcoolers.com/refrigeration/1-hp-r-454a-walk-in-cooler-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/3-4-hp-r-454a-walk-in-cooler-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt