3 1/2 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 11,400 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 8 current R-454A condensing units at 3-1/2 HP, rated 11,430 BTU/h at 95°F ambient, with the 16 unit coolers matched to that capacity, for a walk-in freezer holding 0°F to -10°F.

- **Capacity.** 11,930 BTU/h at 90°F ambient and 11,430 BTU/h at 95°F, about 1.0 tons of refrigeration.
- **Next sizes.** Smaller: [3 HP R-454A walk-in freezer system](https://www.frigidcoolers.com/refrigeration/3-hp-r-454a-walk-in-freezer-refrigeration-system) (9,390 BTU/h). Larger: [4 HP R-454A walk-in freezer system](https://www.frigidcoolers.com/refrigeration/4-hp-r-454a-walk-in-freezer-refrigeration-system) (14,500 BTU/h).
- **Same horsepower in R-448A.** [3-1/2 HP R-448A walk-in freezer system](https://www.frigidcoolers.com/refrigeration/3-1-2-hp-r-448a-walk-in-freezer-refrigeration-system), 4 condensing units, 11,140 BTU/h at 95°F ambient.

- **3-1/2** Horsepower
- **11,430** BTU/h at 95°F ambient
- **8** Condensing units
- **16** Matched evaporators

## 3-1/2 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*3-1/2 HP R-454A Low Temperature (Freezer) condensing units, 8 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBON350L4ADA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 11,930 | 11,430 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WBON350L4AEA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 11,930 | 11,430 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WBON350L4AGA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 11,930 | 11,430 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WFON350L4ADA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 11,930 | 11,430 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WFON350L4ADANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 11,930 | 11,430 | 208-230/1/60 · 1-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WFON350L4AEA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 11,930 | 11,430 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WFON350L4AEANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 11,930 | 11,430 | 208-230/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |
| **WFON350L4AGA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 11,930 | 11,430 | 460/3/60 · 3-ph | 28-1/4 × 39-7/8 × 21-1/4″ | 255 lb |

Manufacturer ratings at -20°F suction.

## Which 3 1/2 HP R-454A model fits your site

3 1/2 HP R-454A is rated up to 11,430 BTU/h at 95°F (about 1.0 tons) at -20°F suction, from 8 Next-Gen Mini-Con models. Compared with the 3 HP below it: 2,040 BTU/h more (22%), the same cabinet, 255 lb against 245 lb. Of its 16 matched unit coolers, 11 also serve the 3 HP. The 4 HP above it is rated 14,500 BTU/h: a different cabinet, 352 lb against 255 lb here.

- **Next-Gen Mini-Con**, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 255 lb; 11,930 BTU/h at 90°F and 11,430 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- **Indoors or outdoors.** WBON350L4ADA on 208-230 V single phase; WBON350L4AEA on 208-230 V three phase; WBON350L4AGA on 460 V three phase.
- **Outdoors only.** WFON350L4ADA and WFON350L4ADANT on 208-230 V single phase; WFON350L4AEA and WFON350L4AEANT on 208-230 V three phase; WFON350L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.
- **Other refrigerant.** The same 3 1/2 HP in R-448A (4 models, Preassembled Remote) is rated 11,140 BTU/h at 95°F, 3% less at the top of the range than R-454A, and weighs 255 lb. See the [3-1/2 HP R-448A walk-in freezer system](https://www.frigidcoolers.com/refrigeration/3-1-2-hp-r-448a-walk-in-freezer-refrigeration-system).

## Evaporators used with this system

A 3-1/2 HP R-454A condensing unit is matched to 16 low-temperature unit coolers: 8 low profile, 4 center mount and 4 medium profile, rated 9,200 to 16,000 BTU/h.

*Center mount, electric defrost, 208-230/1/60: 4 models*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAE6E107DDA** | 10,700 | 1,144 | 2 | 56 × 28-3/8 × 11-1/4″ |
| **WAE6E129DDA** | 12,900 | 1,806 | 3 | 76 × 28-3/8 × 11-1/4″ |
| **WAE6E149DDA** | 14,900 | 1,716 | 3 | 76 × 28-3/8 × 11-1/4″ |
| **WAE6E160DDA** | 16,000 | 2,408 | 4 | 96 × 28-3/8 × 11-1/4″ |

*Low profile, electric defrost, 208-230/1/60: 8 models*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAL6E092DDA** | 9,200 | 1,570 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| **WAL4E099DDA** | 9,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6E110DDA** | 11,000 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| **WAL4E114DDA** | 11,400 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| **WAL6E129DDA** | 12,900 | 1,550 | 2 | 43-5/8 × 15-1/2 × 18-1/8″ |
| **WAL4E133DDA** | 13,300 | 2,325 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| **WAL6E148DDA** | 14,800 | 2,355 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| **WAL4E150DDA** | 15,000 | 3,140 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |

*Medium profile, electric defrost: 4 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM4E129DDA** 208-230/1/60 **WAM4E129EDA** 208-230/3/60 **WAM4E129FDA** 460/1/60 **WAM4E129GDA** 460/3/60 | 12,900 | 3,580 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |

Coil ratings use their own, smaller temperature difference, so they read higher than the condensing unit and do not compare one for one. Questions: 954-237-6753.

## 3-1/2 HP R-454A freezer system questions

### How many BTU is a 3 1/2 HP R-454A walk-in freezer system?

The 8 R-454A condensing units in this class are rated 11,930 BTU/h at 90°F ambient and 11,430 BTU/h at 95°F, about 1.0 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at -20°F suction). In R-448A the same horsepower is rated 11,140 BTU/h.

### What size walk-in freezer does a 3 1/2 HP system fit?

3 1/2 HP is above our standard freezer packages, the largest of which carries 2 1/2 HP on an 8x10 or 10x10. We choose it at quote when the heat load calls for about 11,400 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

### Which 3 1/2 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON350L4ADA on 208-230 V single phase; WBON350L4AEA on 208-230 V three phase; WBON350L4AGA on 460 V three phase. Outdoors only: WFON350L4ADA and WFON350L4ADANT on 208-230 V single phase; WFON350L4AEA and WFON350L4AEANT on 208-230 V three phase; WFON350L4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

### Is the 3 1/2 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON350L4ADA, WFON350L4ADA and WFON350L4ADANT. 208-230 V three phase: WBON350L4AEA, WFON350L4AEA and WFON350L4AEANT. 460 V three phase: WBON350L4AGA and WFON350L4AGA.

### How big and heavy is a 3 1/2 HP R-454A condensing unit?

**Next-Gen Mini-Con**, 8 models: cabinet 28 1/4 × 39 7/8 × 21 1/4 in., 255 lb; 11,930 BTU/h at 90°F and 11,430 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

## Need a 3 1/2 HP R-454A system sized for your walk-in freezer?

Send the inside dimensions and what it will store, tell us where the 3 1/2 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 3-1/2 HP R-454A cooler](https://www.frigidcoolers.com/refrigeration/3-1-2-hp-r-454a-walk-in-cooler-refrigeration-system) · [4 HP R-454A cooler →](https://www.frigidcoolers.com/refrigeration/4-hp-r-454a-walk-in-cooler-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/3-1-2-hp-r-454a-walk-in-freezer-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt