# 2-3/4 HP R-454A walk-in cooler refrigeration system

Updated November 22, 2026

2 3/4 HP is picked at quote when a walk-in cooler needs about 24,900 BTU/h at 95°F, nearly double the horsepower of our standard 10x12 (1 1/2 HP): large custom boxes, glass door walls and coolers outdoors. This class has 8 current R-454A condensing units at 2-3/4 HP, rated 24,880 BTU/h at 95°F ambient, with the 35 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

- **Capacity.** 25,970 BTU/h at 90°F ambient and 24,880 BTU/h at 95°F, about 2.1 tons of refrigeration.
- **Next sizes.** Smaller: [2-1/2 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/2-1-2-hp-r-454a-walk-in-cooler-refrigeration-system) (18,490 BTU/h). Larger: [3 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/3-hp-r-454a-walk-in-cooler-refrigeration-system) (27,380 BTU/h).

- **2-3/4** Horsepower
- **24,880** BTU/h at 95°F ambient
- **8** Condensing units
- **35** Matched evaporators

## 2-3/4 HP R-454A condensing units

R-454A is an A2L refrigerant: lower GWP, mildly flammable, installed to the manufacturer’s A2L requirements. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*2-3/4 HP R-454A Medium Temperature (Cooler) condensing units, 8 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBON280E4ADA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 25,970 | 24,880 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WBON280E4AEA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 25,970 | 24,880 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WBON280E4AGA** | Next-Gen Mini-Con | Indoor / Outdoor | Scroll · Non-Flooded | 25,970 | 24,880 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WFON280E4ADA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 25,970 | 24,880 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WFON280E4ADANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 25,970 | 24,880 | 208-230/1/60 · 1-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WFON280E4AEA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 25,970 | 24,880 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WFON280E4AEANT** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 25,970 | 24,880 | 208-230/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 305 lb |
| **WFON280E4AGA** | Next-Gen Mini-Con | Outdoor | Scroll · Flooded | 25,970 | 24,880 | 460/3/60 · 3-ph | 33 × 43-7/8 × 35″ | 305 lb |

Manufacturer ratings at 25°F suction.

## Which 2 3/4 HP R-454A model fits your site

2 3/4 HP R-454A is a big step up from the 2 1/2 HP: 24,880 BTU/h at 95°F against 18,490, about 35% more, in a larger cabinet (33 × 43 7/8 × 35 in., 305 lb against 230 lb). The 3 HP above it uses that same cabinet and weight for 27,380 BTU/h. No R-454A cooler size is matched to more unit coolers than this one: 35, in low profile, medium profile and center mount types, which gives room to work around a low ceiling or an awkward box.

- **Next-Gen Mini-Con**, 8 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 25,970 BTU/h at 90°F and 24,880 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.
- **Indoors or outdoors.** WBON280E4ADA on 208-230 V single phase; WBON280E4AEA on 208-230 V three phase; WBON280E4AGA on 460 V three phase.
- **Outdoors only.** WFON280E4ADA and WFON280E4ADANT on 208-230 V single phase; WFON280E4AEA and WFON280E4AEANT on 208-230 V three phase; WFON280E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

## Evaporators used with this system

A 2-3/4 HP R-454A condensing unit is matched to 35 medium-temperature unit coolers: 21 medium profile, 8 low profile and 6 center mount, rated 20,700 to 33,600 BTU/h.

*Center mount, air defrost: 6 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAE6A207ADA** 115/1/60 **WAE6A207DDA** 208-230/1/60 | 20,700 | 2,288 | 4 | 96 × 28-3/8 × 11-1/4″ |
| **WAE6A249ADA** 115/1/60 **WAE6A249DDA** 208-230/1/60 | 24,900 | 2,860 | 5 | 116 × 28-3/8 × 11-1/4″ |
| **WAE6A316ADA** 115/1/60 **WAE6A316DDA** 208-230/1/60 | 31,600 | 3,150 | 5 | 116 × 28-3/8 × 13-3/4″ |

*Low profile, air defrost: 8 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAL6A220ADA** 115/1/60 **WAL6A220DDA** 208-230/1/60 | 22,000 | 2,325 | 3 | 60-1/8 × 15-1/2 × 18-1/8″ |
| **WAL6A234ADA** 115/1/60 **WAL6A234DDA** 208-230/1/60 | 23,400 | 3,140 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6A289ADA** 115/1/60 **WAL6A289DDA** 208-230/1/60 | 28,900 | 3,140 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |
| **WAL6A316ADA** 115/1/60 **WAL6A316DDA** 208-230/1/60 | 31,600 | 3,199 | 4 | 76-5/8 × 15-1/2 × 18-1/8″ |

*Medium profile, air defrost: 9 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM6A219ADA** 115/1/60 **WAM6A219DDA** 208-230/1/60 **WAM6A219FDA** 460/1/60 | 21,900 | 3,190 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6A268ADA** 115/1/60 **WAM6A268DDA** 208-230/1/60 **WAM6A268FDA** 460/1/60 | 26,800 | 2,950 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6A336ADA** 115/1/60 **WAM6A336DDA** 208-230/1/60 **WAM6A336FDA** 460/1/60 | 33,600 | 6,950 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |

*Medium profile, electric defrost: 12 models*

| Model and voltage | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WAM6D218DDA** 208-230/1/60 **WAM6D218EDA** 208-230/3/60 **WAM6D218FDA** 460/1/60 **WAM6D218GDA** 460/3/60 | 21,900 | 3,190 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6D267DDA** 208-230/1/60 **WAM6D267EDA** 208-230/3/60 **WAM6D267FDA** 460/1/60 **WAM6D267GDA** 460/3/60 | 26,800 | 2,950 | 1 | 47-1/2 × 21-5/16 × 33-7/8″ |
| **WAM6D335DDA** 208-230/1/60 **WAM6D335EDA** 208-230/3/60 **WAM6D335FDA** 460/1/60 **WAM6D335GDA** 460/3/60 | 33,600 | 6,950 | 2 | 80-1/2 × 21-5/16 × 33-7/8″ |

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

## 2-3/4 HP R-454A cooler system questions

### How many BTU is a 2 3/4 HP R-454A walk-in cooler system?

The 8 R-454A condensing units in this class are rated 25,970 BTU/h at 90°F ambient and 24,880 BTU/h at 95°F, about 2.1 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction).

### What size walk-in cooler does a 2 3/4 HP system fit?

2 3/4 HP is picked at quote when a walk-in cooler needs about 24,900 BTU/h at 95°F, nearly double the horsepower of our standard 10x12 (1 1/2 HP): large custom boxes, glass door walls and coolers outdoors.

### Which 2 3/4 HP R-454A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBON280E4ADA on 208-230 V single phase; WBON280E4AEA on 208-230 V three phase; WBON280E4AGA on 460 V three phase. Outdoors only: WFON280E4ADA and WFON280E4ADANT on 208-230 V single phase; WFON280E4AEA and WFON280E4AEANT on 208-230 V three phase; WFON280E4AGA on 460 V three phase. The outdoor-only models are listed with a flooded condenser, for head pressure control in cold weather.

### Is the 2 3/4 HP R-454A unit single phase, three phase or 460 V?

208-230 V single phase: WBON280E4ADA, WFON280E4ADA and WFON280E4ADANT. 208-230 V three phase: WBON280E4AEA, WFON280E4AEA and WFON280E4AEANT. 460 V three phase: WBON280E4AGA and WFON280E4AGA.

### How big and heavy is a 2 3/4 HP R-454A condensing unit?

**Next-Gen Mini-Con**, 8 models: cabinet 33 × 43 7/8 × 35 in., 305 lb; 25,970 BTU/h at 90°F and 24,880 BTU/h at 95°F; 208-230 V single phase, 208-230 V three phase and 460 V three phase.

### How does a 2 3/4 HP R-454A system compare with a 3 HP?

Both are eight Next-Gen Mini-Con models in the same 305 lb cabinet. The 2 3/4 HP is rated 24,880 BTU/h at 95°F and the 3 HP 27,380, which is 2,500 more. The 2 3/4 HP is matched to 35 unit coolers and the 3 HP to 28; 26 of them are common to both.

## Need a 2 3/4 HP R-454A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 2 3/4 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 2-1/2 HP R-454A freezer](https://www.frigidcoolers.com/refrigeration/2-1-2-hp-r-454a-walk-in-freezer-refrigeration-system) · [3 HP R-454A cooler →](https://www.frigidcoolers.com/refrigeration/3-hp-r-454a-walk-in-cooler-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/2-3-4-hp-r-454a-walk-in-cooler-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt