title: "1-1/4 HP R-448A Walk-In Cooler Refrigeration System | Frigid Coolers LLC"
description: "1-1/4 HP R-448A walk-in cooler system, sized at quote from your heat load: 12,140 BTU/h at 95°F, 4 condensing units, 10 matched evaporators."
url: "https://www.frigidcoolers.com/refrigeration/1-1-4-hp-r-448a-walk-in-cooler-refrigeration-system"
language: "en"
published: "2026-10-07"
updated: "2026-11-22T12:50:04+00:00"
---

# 1-1/4 HP R-448A walk-in cooler refrigeration system

Updated November 22, 2026

1 1/4 HP is not a standard cooler package size (those run from 1/2 HP on a 6x6 to 1 1/2 HP on a 10x12). We choose it at quote when the heat load calls for about 12,100 BTU/h at 95°F: a custom size, glass doors or an outdoor location. This class has 4 current R-448A condensing units at 1-1/4 HP, rated 12,140 BTU/h at 95°F ambient, with the 10 unit coolers matched to that capacity, for a walk-in cooler holding 35°F.

- **Capacity.** 12,580 BTU/h at 90°F ambient and 12,140 BTU/h at 95°F, about 1.0 tons of refrigeration.
- **Next sizes.** Smaller: [1 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/1-hp-r-448a-walk-in-cooler-refrigeration-system) (9,380 to 9,680 BTU/h). Larger: [1-1/2 HP R-448A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/1-1-2-hp-r-448a-walk-in-cooler-refrigeration-system) (13,690 BTU/h).
- **Same horsepower in R-454A.** [1-1/4 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/1-1-4-hp-r-454a-walk-in-cooler-refrigeration-system), 8 condensing units, 12,660 BTU/h at 95°F ambient.

- **1-1/4** Horsepower
- **12,140** BTU/h at 95°F ambient
- **4** Condensing units
- **10** Matched evaporators

## 1-1/4 HP R-448A condensing units

R-448A is the non-flammable A1 blend that replaces R-404A. [Compare R-448A and R-454A](https://www.frigidcoolers.com/galleries/equipment#faq).

*1-1/4 HP R-448A Medium Temperature (Cooler) condensing units, 4 models*

| Model | Series | Siting | Compressor | BTU/h @ 90°F | BTU/h @ 95°F | Electrical | D × W × H | Weight |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| **WBO150E4SDA** | Preassembled Remote | Indoor / Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 1-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
| **WBO150E4SEA** | Preassembled Remote | Indoor / Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 3-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
| **WFO150E4SDA** | Preassembled Remote | Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 1-ph | 28.25 × 39.875 × 18.75″ | 205 lb |
| **WFO150E4SEA** | Preassembled Remote | Outdoor | Scroll | 12,580 | 12,140 | 208-230 · 3-ph | 28.25 × 39.875 × 18.75″ | 205 lb |

Manufacturer ratings at 25°F suction.

## Which 1 1/4 HP R-448A model fits your site

1 1/4 HP R-448A is rated up to 12,140 BTU/h at 95°F (about 1.0 tons) at 25°F suction, from 4 Preassembled Remote models. Compared with the 1 HP below it: 2,460 BTU/h more (25%), a different cabinet, 205 lb against 195 lb. Of its 10 matched unit coolers, 5 also serve the 1 HP. The 1 1/2 HP above it is rated 13,690 BTU/h: the same cabinet, 210 lb against 205 lb here.

- **Preassembled Remote**, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 205 lb; 12,580 BTU/h at 90°F and 12,140 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.
- **Indoors or outdoors.** WBO150E4SDA on 208-230 V single phase; WBO150E4SEA on 208-230 V three phase.
- **Outdoors only.** WFO150E4SDA on 208-230 V single phase; WFO150E4SEA on 208-230 V three phase.
- **Other refrigerant.** The same 1 1/4 HP in R-454A (8 models, Next-Gen Mini-Con) is rated 12,660 BTU/h at 95°F, 4% more at the top of the range than R-448A, and weighs 205 lb. See the [1-1/4 HP R-454A walk-in cooler system](https://www.frigidcoolers.com/refrigeration/1-1-4-hp-r-454a-walk-in-cooler-refrigeration-system).

## Evaporators used with this system

A 1-1/4 HP R-448A condensing unit is matched to 10 medium-temperature unit coolers: 4 ultra low profile center mount, 4 low profile and 2 slim display case, rated 9,900 to 16,600 BTU/h.

*Ultra low profile center mount, air defrost, 115 V: 4 models*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WE6A084ADAS** | 9,900 | 1,144 | 2 | 52 × 28.375 × 11.25″ |
| **WE6A104ADAS** | 12,300 | 1,806 | 3 | 72 × 28.375 × 11.25″ |
| **WE6A128ADAS** | 15,100 | 1,716 | 3 | 72 × 28.375 × 11.25″ |
| **WE6A141ADAS** | 16,600 | 2,408 | 4 | 92 × 28.375 × 11.25″ |

*Low profile, air defrost, 115 V: 4 models*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **WL6A094ADAS** | 10,900 | 1,570 | 2 | 43.625 × 15.5 × 18.125″ |
| **WL6A117ADAS** | 13,600 | 1,550 | 2 | 43.625 × 15.5 × 18.125″ |
| **WL6A130ADAS** | 15,300 | 1,550 | 2 | 43.625 × 15.5 × 18.125″ |
| **WL6A141ADAS** | 16,300 | 2,355 | 3 | 60.125 × 15.5 × 18.125″ |

*Slim display case, air defrost, 115 V: 2 models*

| Model | BTU/h | CFM | Fans | L × W × H |
| --- | --- | --- | --- | --- |
| **ASLA45098ADAS** | 10,700 | 1,900 | 4 | 93 × 19.8125 × 9.1875″ |
| **ASLA55122ADAS** | 13,300 | 2,375 | 5 | 116 × 19.8125 × 9.1875″ |

Coil ratings use their own temperature difference and do not compare one for one with the condensing unit. Questions: 954-237-6753.

## 1-1/4 HP R-448A cooler system questions

### How many BTU is a 1 1/4 HP R-448A walk-in cooler system?

The 4 R-448A condensing units in this class are rated 12,580 BTU/h at 90°F ambient and 12,140 BTU/h at 95°F, about 1.0 tons of refrigeration (one ton is 12,000 BTU/h; manufacturer ratings at 25°F suction). In R-454A the same horsepower is rated 12,660 BTU/h.

### What size walk-in cooler does a 1 1/4 HP system fit?

1 1/4 HP is not a standard cooler package size (those run from 1/2 HP on a 6x6 to 1 1/2 HP on a 10x12). We choose it at quote when the heat load calls for about 12,100 BTU/h at 95°F: a custom size, glass doors or an outdoor location. We do the heat load calculation before anything is quoted.

### Which 1 1/4 HP R-448A condensing unit goes indoors, and which outdoors?

Indoors or outdoors: WBO150E4SDA on 208-230 V single phase; WBO150E4SEA on 208-230 V three phase. Outdoors only: WFO150E4SDA on 208-230 V single phase; WFO150E4SEA on 208-230 V three phase.

### Is the 1 1/4 HP R-448A unit single phase, three phase or 460 V?

208-230 V single phase: WBO150E4SDA and WFO150E4SDA. 208-230 V three phase: WBO150E4SEA and WFO150E4SEA. No model in this class runs on 460 V.

### How big and heavy is a 1 1/4 HP R-448A condensing unit?

**Preassembled Remote**, 4 models: cabinet 28 1/4 × 39 7/8 × 18 3/4 in., 205 lb; 12,580 BTU/h at 90°F and 12,140 BTU/h at 95°F; 208-230 V single phase and 208-230 V three phase.

## Need a 1 1/4 HP R-448A system sized for your walk-in cooler?

Send the inside dimensions and what it will store, tell us where the 1 1/4 HP unit will sit and what power the site has, and you get a drawing and a price.

Condensing units **UL and cUL listed**; unit coolers also **NSF approved** and AWEF certified. [Listing details](https://www.frigidcoolers.com/galleries/equipment).

[← 1 HP R-448A freezer](https://www.frigidcoolers.com/refrigeration/1-hp-r-448a-walk-in-freezer-refrigeration-system) · [1-1/3 HP R-448A freezer →](https://www.frigidcoolers.com/refrigeration/1-1-3-hp-r-448a-walk-in-freezer-refrigeration-system)

---

Frigid Coolers LLC, Miami, Florida. Phone 954-237-6753 (call, or text pictures), sales@frigidcoolers.com. Quote form: https://www.frigidcoolers.com/#quote. This file is the Markdown copy of https://www.frigidcoolers.com/refrigeration/1-1-4-hp-r-448a-walk-in-cooler-refrigeration-system. Site map for AI assistants: https://www.frigidcoolers.com/llms.txt